 "$schema": "https://aij.eddy3d.com/api/schemas/cases.schema.json",
 "schema_version": "2.6.0",
 "data_version": "7ee0afb7cec8197e7edde0e7c282c8e6e9670b7cef003e6aa218c5a536817f48",
 "license": "CC-BY-4.0",
 "cases": [
  {
   "id": "A",
   "slug": "case-a",
   "title": "Case A — 1:1:2 building",
   "summary": "Isolated 1:1:2 building, velocity field (split-fibre hot wire).",
   "configuration": {
    "building": "1:1:2 (width : depth : height) prism",
    "b_m": 0.08,
    "H_m": 0.16,
    "Re_H": 24000,
    "U_H_m_s": 4.491,
    "wind_directions_deg": [
     0
    ],
    "measurement_planes": [
     "vertical centre plane y/b = 0",
     "horizontal z/b = 0.125",
     "horizontal z/b = 1.25"
    ],
    "instrument": "hot-wire anemometer, split-fibre probes (DANTEC 55R55 streamwise, 55R57 spanwise/vertical), 1000 Hz, 60 s per point, 500 Hz low-pass",
    "tunnel": "Technical Research Institute, Shimizu Corporation, Tokyo",
    "scale_note": "model scale; Eddy3D solves it at 1:100 (b = 8 m, H = 16 m) with the tunnel velocities"
   },
   "quantities": [
    "U",
    "V",
    "W",
    "uu",
    "vv",
    "ww",
    "k"
   ],
   "units": {
    "length": "m (model scale)",
    "velocity": "m/s",
    "variance": "m^2/s^2",
    "k": "m^2/s^2"
   },
   "frame": {
    "origin": "building centre on the ground plane",
    "x": "+x streamwise (the wind at WD = 0 blows toward +x); building spans x in [-0.04, 0.04]",
    "y": "+y lateral; building spans y in [-0.04, 0.04]; points published on the y <= 0 half by the tunnel's symmetry convention",
    "z": "+z up from the ground; roof at z = 0.16"
   },
   "counts": {
    "rows": 186,
    "distinct_points": 186,
    "configurations": 1
   },
   "engines": {
    "openfoam12-realizableKE": "scored",
    "openlb": "scored",
    "fluidx3d": "scored",
    "ml-surrogate": "scored"
   },
   "doi": "10.5281/zenodo.15050147",
   "links": {
    "case": "https://aij.eddy3d.com/api/cases/A.json",
    "points": "https://aij.eddy3d.com/api/cases/A/points.json",
    "points_csv": "https://aij.eddy3d.com/api/cases/A/points.csv?v=a46201996b22",
    "geometry": "https://aij.eddy3d.com/api/cases/A/geometry.json",
    "geometry_stl": "https://aij.eddy3d.com/api/cases/A/geometry.stl?v=89acdfbbff84",
    "validation": "https://aij.eddy3d.com/api/cases/A/validation.json",
    "page": "https://aij.eddy3d.com/cases/case-a/",
    "render": "https://aij.eddy3d.com/assets/geometry/case-a.png"
   }
  },
  {
   "id": "B",
   "slug": "case-b",
   "title": "Case B — 1:4:4 slab",
   "summary": "Isolated 1:4:4 slab, velocity field (split-fibre hot wire).",
   "configuration": {
    "building": "1:4:4 (depth : width : height) slab",
    "depth_m": 0.05,
    "width_m": 0.2,
    "H_m": 0.2,
    "Re_H": 72000,
    "U_H_m_s": 5.133,
    "wind_directions_deg": [
     0
    ],
    "measurement_planes": [
     "vertical centre plane y/H = 0",
     "horizontal z/H = 1/16"
    ],
    "instrument": "hot-wire anemometer, split-fibre probe, 100 Hz, 60 s per point",
    "tunnel": "Niigata Institute of Technology, Kashiwazaki",
    "scale_note": "model scale; Eddy3D solves it at 1:100 (H = 20 m) with the tunnel velocities"
   },
   "quantities": [
    "U",
    "V",
    "W",
    "uu",
    "vv",
    "ww",
    "k"
   ],
   "units": {
    "length": "m (model scale; converted from the published millimetres)",
    "velocity": "m/s",
    "variance": "m^2/s^2",
    "k": "m^2/s^2"
   },
   "frame": {
    "origin": "building centre on the ground plane",
    "x": "+x streamwise (the wind at WD = 0 blows toward +x); slab spans x in [-0.025, 0.025]",
    "y": "+y lateral; slab spans y in [-0.10, 0.10]; points published on the y <= 0 half by the tunnel's symmetry convention",
    "z": "+z up from the ground; roof at z = 0.20"
   },
   "counts": {
    "rows": 224,
    "distinct_points": 224,
    "configurations": 1
   },
   "engines": {
    "openfoam12-realizableKE": "scored",
    "openlb": "scored",
    "fluidx3d": "scored",
    "ml-surrogate": "scored"
   },
   "doi": "10.5281/zenodo.15401455",
   "links": {
    "case": "https://aij.eddy3d.com/api/cases/B.json",
    "points": "https://aij.eddy3d.com/api/cases/B/points.json",
    "points_csv": "https://aij.eddy3d.com/api/cases/B/points.csv?v=dec97c21217a",
    "geometry": "https://aij.eddy3d.com/api/cases/B/geometry.json",
    "geometry_stl": "https://aij.eddy3d.com/api/cases/B/geometry.stl?v=e6de70eeb17d",
    "validation": "https://aij.eddy3d.com/api/cases/B/validation.json",
    "page": "https://aij.eddy3d.com/cases/case-b/",
    "render": "https://aij.eddy3d.com/assets/geometry/case-b.png"
   }
  },
  {
   "id": "C",
   "slug": "case-c",
   "title": "Case C — 3 × 3 block array",
   "summary": "3 x 3 array of 0.20 m cubes, centre block at 0D / 1D / 2D, pedestrian-height scalar speed (thermistor), 3 wind directions.",
   "configuration": {
    "array": "3 x 3 cubes, D = 0.20 m, block centres at x, y in {-0.4, 0, +0.4} m (pitch 0.40 m = 2D, street width D)",
    "D_m": 0.2,
    "centre_building": {
     "0D": "no centre building",
     "1D": "0.2 x 0.2 x 0.2 m (same as the surroundings)",
     "2D": "0.2 x 0.2 x 0.4 m"
    },
    "wind_directions_deg": [
     0,
     22.5,
     45
    ],
    "configurations": 9,
    "configurations_note": "3 centre-building heights x 3 wind directions; all nine share the identical 120-point set",
    "measurement_height_m": 0.02,
    "measurement_height_note": "z = 0.1 D for every point (2.0 m at the 1:100 scale Eddy3D solves it at)",
    "Re_D": 52000,
    "U_H_m_s": 3.654,
    "U_H_note": "U at z = D = 0.20 m from AF_caseC.csv; the data paper states U_H = 3.65 m/s",
    "instrument": "thermistor anemometer (omnidirectional scalar speed), 1 Hz, 30 s per point; approach flow by I-type hot wire, 500 Hz, 30 s",
    "tunnel": "Technology Development Division, Fujita Corporation, Tokyo",
    "pitch_note": "The 0.40 m pitch is read from MP-z-caseC.png and Figure 3 of the data paper (street = D); the 120-point grid alone bounds the pitch to (0.35, 0.40] m (the 49 absent nodes of the 13 x 13 grid are exactly the nine footprints for 0.375 m as well as 0.40 m)."
   },
   "quantities": [
    "Vs"
   ],
   "units": {
    "length": "m (model scale)",
    "velocity": "m/s"
   },
   "frame": {
    "origin": "array centre on the ground plane (centre of the middle block)",
    "x": "+x streamwise at WD = 0 (checked three ways on the data: y -> -y is a symmetry, the x <= -0.25 band is faster than x >= +0.25 in every configuration, and the regression slope of Vs is most negative within 0.8-4.3 deg of +x)",
    "y": "+y lateral",
    "z": "+z up; all points at z = 0.02"
   },
   "counts": {
    "rows": 1080,
    "distinct_points": 120,
    "configurations": 9
   },
   "engines": {
    "openfoam12-realizableKE": "scored",
    "openlb": "not comparable",
    "fluidx3d": "pending",
    "ml-surrogate": "scored"
   },
   "doi": "10.5281/zenodo.15401791",
   "links": {
    "case": "https://aij.eddy3d.com/api/cases/C.json",
    "points": "https://aij.eddy3d.com/api/cases/C/points.json",
    "points_csv": "https://aij.eddy3d.com/api/cases/C/points.csv?v=7448f0ceae37",
    "geometry": "https://aij.eddy3d.com/api/cases/C/geometry.json",
    "geometry_stl": "https://aij.eddy3d.com/api/cases/C/geometry.stl?v=b8c31c57c453",
    "validation": "https://aij.eddy3d.com/api/cases/C/validation.json",
    "page": "https://aij.eddy3d.com/cases/case-c/",
    "render": "https://aij.eddy3d.com/assets/geometry/case-c-2d.png"
   }
  },
  {
   "id": "D",
   "slug": "case-d",
   "title": "Case D — high-rise among city blocks",
   "summary": "1:1:4 tower in a regular array of 82 low blocks, pedestrian-height scalar speed (thermistor, 3 wind directions) plus a 33-point split-fibre velocity field at WD = 0.",
   "configuration": {
    "tower": "0.25H x 0.25H x H = 62.5 x 62.5 x 250 mm (1:1:4)",
    "H_m": 0.25,
    "blocks": "82 blocks of 0.4H x 0.4H x 0.1H = 100 x 100 x 25 mm",
    "roads": "0.1H / 0.2H / 0.3H = 25 / 50 / 75 mm; 9 columns in x (pitch alternating 175 / 150 mm), 11 rows in y (pitch 125 mm); corners cut by the turntable circle",
    "array_extent_m": {
     "x": [
      -0.7,
      0.7
     ],
     "y": [
      -0.675,
      0.675
     ],
     "z": [
      0,
      0.25
     ]
    },
    "scale": "1:400 (H = 100 m full scale; the 5 mm measurement plane = 2 m)",
    "Re_H": 110000,
    "U_H_m_s": 6.65,
    "wind_directions_deg": [
     0,
     22.5,
     45
    ],
    "measurement_height_m": 0.005,
    "instrument": "thermistor anemometer (78 points x 3 directions; 66 measured per direction, 12 points in the band around the tower unmeasured) and split-fibre probe (33 points at WD = 0: U, V, W, variances, k)",
    "tunnel": "see the data paper (Kikumoto et al. 2026, section 3.4)"
   },
   "quantities": [
    "Vs",
    "U",
    "V",
    "W",
    "uu",
    "vv",
    "ww",
    "k"
   ],
   "units": {
    "length": "m (model scale; converted from the workbook's millimetres)",
    "velocity": "m/s",
    "variance": "m^2/s^2",
    "k": "m^2/s^2"
   },
   "frame": {
    "origin": "tower centre on the ground plane (the array's bounding box is centred on it)",
    "x": "+x streamwise at WD = 0 (the 0 deg thermistor field is exactly y-mirror symmetric; the split-fibre U is positive at the stream-like points and negative in the tower's windward horseshoe)",
    "y": "+y lateral",
    "z": "+z up; all points at z = 0.005"
   },
   "counts": {
    "rows": 267,
    "distinct_points": 78,
    "configurations": 4
   },
   "engines": {
    "openfoam12-realizableKE": "scored",
    "openlb": "not comparable",
    "fluidx3d": "pending",
    "ml-surrogate": "scored"
   },
   "doi": "10.5281/zenodo.15402668",
   "links": {
    "case": "https://aij.eddy3d.com/api/cases/D.json",
    "points": "https://aij.eddy3d.com/api/cases/D/points.json",
    "points_csv": "https://aij.eddy3d.com/api/cases/D/points.csv?v=596246341e73",
    "geometry": "https://aij.eddy3d.com/api/cases/D/geometry.json",
    "geometry_stl": "https://aij.eddy3d.com/api/cases/D/geometry.stl?v=531895531271",
    "validation": "https://aij.eddy3d.com/api/cases/D/validation.json",
    "page": "https://aij.eddy3d.com/cases/case-d/",
    "render": "https://aij.eddy3d.com/assets/geometry/case-d.png"
   }
  },
  {
   "id": "E",
   "slug": "case-e",
   "title": "Case E — Niigata district",
   "summary": "Real district in Niigata at 1:250, before and after a 60 m high-rise and two 18 m mid-rises; pedestrian-height velocity ratio (thermistor), 16 wind directions.",
   "configuration": {
    "district": "Niigata City urban area near the Shinano River; dense low-rise stock (median top 6 m, max 30 m)",
    "scale": "1:250",
    "states": {
     "bc": "before construction (sites of A, B, C empty)",
     "ac": "after construction of A (60 m high-rise), B and C (18 m mid-rises)"
    },
    "new_buildings": {
     "A": "60 m high-rise, bbox x [-79.3, -49.1], y [-17.1, 18.3]",
     "B": "18 m, bbox x [41.5, 61.0], y [-18.5, 8.5]",
     "C": "18 m, bbox x [64.0, 83.5], y [-8.0, 19.0]"
    },
    "wind_directions": [
     "N",
     "NNE",
     "NE",
     "ENE",
     "E",
     "ESE",
     "SE",
     "SSE",
     "S",
     "SSW",
     "SW",
     "WSW",
     "W",
     "WNW",
     "NW",
     "NNW"
    ],
    "wind_directions_deg": [
     0.0,
     22.5,
     45.0,
     67.5,
     90.0,
     112.5,
     135.0,
     157.5,
     180.0,
     202.5,
     225.0,
     247.5,
     270.0,
     292.5,
     315.0,
     337.5
    ],
    "measurement_height_m": 2.0,
    "measurement_height_note": "2 m full scale = 0.008 m model scale",
    "points": 80,
    "values": 2560,
    "Re": 17000,
    "normalisation": "velocity ratio = mean scalar speed at 2 m / inflow velocity at 15.9 m (the Niigata meteorological station height); U(15.9 m) = 0.504531 x UR = 3.935 m/s with UR = 7.8 m/s at ZR = 250 m",
    "instrument": "thermistor anemometer, 100 Hz, 60 s per point, mean scalar wind speed",
    "tunnel": "Niigata Institute of Technology, Kashiwazaki"
   },
   "quantities": [
    "velocity_ratio"
   ],
   "units": {
    "length": "m (FULL scale)",
    "velocity_ratio": "dimensionless"
   },
   "frame": {
    "origin": "centre of the reproduced area, ground plane",
    "x": "+x EAST (full-scale metres)",
    "y": "+y NORTH (compass rose in MP_caseE.png)",
    "z": "+z up; all points at z = 2.0"
   },
   "counts": {
    "rows": 2560,
    "distinct_points": 80,
    "configurations": 2
   },
   "engines": {
    "openfoam12-realizableKE": "scored",
    "openlb": "not comparable",
    "fluidx3d": "pending",
    "ml-surrogate": "scored"
   },
   "doi": "10.5281/zenodo.15429017",
   "links": {
    "case": "https://aij.eddy3d.com/api/cases/E.json",
    "points": "https://aij.eddy3d.com/api/cases/E/points.json",
    "points_csv": "https://aij.eddy3d.com/api/cases/E/points.csv?v=e6e89432e706",
    "geometry": "https://aij.eddy3d.com/api/cases/E/geometry.json",
    "geometry_stl": "https://aij.eddy3d.com/api/cases/E/geometry.stl?v=c29624fdae6d",
    "validation": "https://aij.eddy3d.com/api/cases/E/validation.json",
    "page": "https://aij.eddy3d.com/cases/case-e/",
    "render": "https://aij.eddy3d.com/assets/geometry/case-e-after.png"
   }
  },
  {
   "id": "F",
   "slug": "case-f",
   "title": "Case F — Shinjuku district",
   "summary": "Shinjuku sub-centre, Tokyo, November 1978: 1:800 tunnel (thermistor, 5 / 9 / 20 m) and a year of field cup anemometers; velocity ratio to the 500 m wind, 12 tunnel and 16 field directions.",
   "configuration": {
    "district": "Shinjuku sub-centre during construction of the high-rise group, building configuration of November 1978",
    "scale": "1:800",
    "model": "terrain and buildings in a disc of radius 725 m (BD_caseF.stl; the readme and the data paper say 800 m / 1600 m diameter)",
    "points": 13,
    "point_numbers": "1-3, 5-11, 13-15 (4 and 12 absent; points 16 and later belong to later construction stages and are not in the dataset)",
    "wind_directions": [
     "N",
     "NNE",
     "NE",
     "ENE",
     "SE",
     "SSE",
     "S",
     "SSW",
     "SW",
     "WNW",
     "NW",
     "NNW"
    ],
    "wind_directions_field": [
     "N",
     "NNE",
     "NE",
     "ENE",
     "E",
     "ESE",
     "SE",
     "SSE",
     "S",
     "SSW",
     "SW",
     "WSW",
     "W",
     "WNW",
     "NW",
     "NNW"
    ],
    "measurement_planes_above_ground_m": [
     5,
     9,
     20
    ],
    "measurement_planes_z_m": [
     15,
     19,
     30
    ],
    "ground_offset_m": 10,
    "normalisation": "velocity ratio = mean speed / the approaching mean speed at the boundary-layer height 500 m (full scale); the field values were converted to it with the tunnel (readme). U(500 m) is 10 m/s in the data paper and 10.65 m/s implied by the profile",
    "instrument": "tunnel: thermistor anemometer, 30 s averaging; field: three-cup anemometer with wind vane, 10-minute means above 5 m/s at the reference roof, December 1977 - November 1978",
    "tunnel": "Shimizu Corporation wind tunnel; cross-section 1.55 m wide, 2.2 m high; power-law inflow, exponent 1/4",
    "reference_roofs": {
     "SMB": "Shinjuku-Mitsui Building, roof G.L.+210 m, anemometer G.L.+237 m, for NW-NE",
     "KDD": "KDD Building, roof G.L.+165 m, anemometer G.L.+187 m, for the other directions"
    }
   },
   "quantities": [
    "velocity_ratio",
    "velocity_ratio_sd"
   ],
   "units": {
    "length": "m (FULL scale)",
    "velocity_ratio": "dimensionless",
    "velocity_ratio_sd": "dimensionless"
   },
   "frame": {
    "origin": "centre of the reproduced district, tunnel floor plane",
    "x": "+x EAST (full-scale metres)",
    "y": "+y NORTH (compass rose in MP_caseF.png)",
    "z": "+z up from the TUNNEL FLOOR; the readme's rule is ground = z - 10 m (the STL's terrain under the points is at z = 5 m)"
   },
   "counts": {
    "rows": 472,
    "distinct_points": 13,
    "configurations": 40
   },
   "engines": {
    "openfoam12-realizableKE": "scored",
    "openlb": "pending",
    "fluidx3d": "pending",
    "ml-surrogate": "pending"
   },
   "doi": "10.5281/zenodo.15589621",
   "links": {
    "case": "https://aij.eddy3d.com/api/cases/F.json",
    "points": "https://aij.eddy3d.com/api/cases/F/points.json",
    "points_csv": "https://aij.eddy3d.com/api/cases/F/points.csv?v=09b109e58dd3",
    "geometry": "https://aij.eddy3d.com/api/cases/F/geometry.json",
    "geometry_stl": "https://aij.eddy3d.com/api/cases/F/geometry.stl?v=8799740aa324",
    "validation": "https://aij.eddy3d.com/api/cases/F/validation.json",
    "page": "https://aij.eddy3d.com/cases/case-f/",
    "render": "https://aij.eddy3d.com/assets/geometry/case-f.png"
   }
  },
  {
   "id": "G",
   "slug": "case-g",
   "title": "Case G — flow behind a tree belt",
   "summary": "Field observation behind the Tsuiji-matsu tree belt (a porous windbreak, 74 m × 2 m × 7 m with a 1.2 m gap below): normalised mean speed and k at 28 points on the centre section (sonic anemometers).",
   "configuration": {
    "belt": "Tsuiji-matsu (Japanese black pine), trimmed to a rectangle; 74 m long (y), 2 m deep (x), 7 m tall, 1.2 m bottom gap; shading rate 81 % after pruning (data paper section 3.7)",
    "H_m": 7.0,
    "depth_m": 2.0,
    "width_m": 74.0,
    "gap_m": 1.2,
    "campaign": "field (full scale)",
    "location": "Taisha-machi, Hikawa-gun, Shimane, Japan; west end of an elementary-school playground",
    "wind_directions_deg": [
     0
    ],
    "measurement_lines": "0.25 H, 0.5 H, 1 H, 2 H, 3 H, 4 H, 5 H behind the belt = x 1.75, 3.5, 7, 14, 21, 28, 35 m (H = 7 m)",
    "measurement_heights_m": [
     1.5,
     3.0,
     4.5,
     6.0
    ],
    "points": 28,
    "instrument": "3-D ultrasonic anemometers (KAIJO DA-600 with TR-90Tx) at four heights on a movable tower, 5 Hz, 10 min or more per line (26 Dec 2000); approach flow 120 min (28 Dec 2000) at 1.5, 3, 6, 9 m",
    "normalisation": "velocity_ratio = U/UH and k_ratio = k/UH^2, UH = the mean wind speed at 7 m during each measurement period (interpolated with the approach flow's power law, index 0.22); nothing is published in m/s",
    "approach_flow_normalisation": "AF_caseG.csv is U/Ub and k/Ub^2 with Ub = U at 9 m; divide by UH/Ub = 0.946 (power law 0.22) for the table's normalisation",
    "scale_note": "full scale: a field observation, there is no model"
   },
   "quantities": [
    "velocity_ratio",
    "k_ratio"
   ],
   "units": {
    "length": "m (full scale)",
    "velocity_ratio": "dimensionless, U/UH",
    "k_ratio": "dimensionless, k/UH^2"
   },
   "frame": {
    "origin": "the leeward face of the tree belt at ground level, on the vertical section through the belt's centre",
    "x": "+x downwind: the belt occupies x in [-2, 0] m, the measurement lines lie behind it at x = 1.75 ... 35 m",
    "y": "+y along the belt (y in [-37, 37] m); every point is on y = 0",
    "z": "+z up; the belt spans z in [1.2, 7] m; points at z = 1.5, 3, 4.5, 6 m"
   },
   "counts": {
    "rows": 28,
    "distinct_points": 28,
    "configurations": 1
   },
   "engines": {
    "openfoam12-realizableKE": "scored",
    "openlb": "pending",
    "fluidx3d": "pending",
    "ml-surrogate": "pending"
   },
   "doi": "10.5281/zenodo.15589666",
   "links": {
    "case": "https://aij.eddy3d.com/api/cases/G.json",
    "points": "https://aij.eddy3d.com/api/cases/G/points.json",
    "points_csv": "https://aij.eddy3d.com/api/cases/G/points.csv?v=914883bf7fec",
    "geometry": "https://aij.eddy3d.com/api/cases/G/geometry.json",
    "geometry_stl": "https://aij.eddy3d.com/api/cases/G/geometry.stl?v=09d23c794155",
    "validation": "https://aij.eddy3d.com/api/cases/G/validation.json",
    "page": "https://aij.eddy3d.com/cases/case-g/",
    "render": "https://aij.eddy3d.com/assets/geometry/case-g.png"
   }
  },
  {
   "id": "H",
   "slug": "case-h",
   "title": "Case H — 1:1:2 building with a floor point source",
   "summary": "Isolated 1:1:2 building with an ethylene point source on the floor behind it: velocity (split-fibre hot wire) and concentration (hydrocarbon analyser) at 876 points.",
   "configuration": {
    "building": "1:1:2 (width : depth : height) prism, 0.10 × 0.10 × 0.20 m",
    "b_m": 0.1,
    "H_m": 0.2,
    "Re_H": 43000,
    "U_H_m_s": 3.226,
    "U_H_note": "the workbook's uH; the readme and the data paper state 3.23 m/s; the workbook's free-stream reference U0 is 5.279 m/s",
    "wind_directions_deg": [
     0
    ],
    "source": "4 mm hole in the floor 0.25 H = 0.05 m behind the leeward face at (0.05, 0, 0); ethylene (C2H4), 100 %, 350 cc/min = 5.83e-6 m3/s",
    "reference_concentration": "c0 = cgas q / (UH H^2) = 45.18 ppm (45.2 in the paper); concentration_ratio = C / c0",
    "measurement_planes": [
     "vertical centre plane y/H = 0",
     "horizontal z/H = 1/16 (y in [-0.2, 0.2])",
     "horizontal z/H = 1/4 and 1/2 (y in [0, 0.2])"
    ],
    "points": 876,
    "instrument": "velocity: constant-temperature anemometer (DANTEC 90C10) with a split-fibre probe (55R55, 55R56, 55R57), 1000 Hz, 120 s; concentration: high-speed total hydrocarbon analyser, 1000 Hz, 120 s",
    "tunnel": "Eiffel-type boundary-layer wind tunnel, Tokyo Polytechnic University, Atsugi (1.0 m high, 1.2 m wide)",
    "scale_note": "model scale; the source states no model:full-scale ratio; Eddy3D solves it at 1:100"
   },
   "quantities": [
    "U",
    "V",
    "W",
    "uu",
    "vv",
    "ww",
    "k",
    "C",
    "c_rms",
    "concentration_ratio"
   ],
   "units": {
    "length": "m (model scale)",
    "velocity": "m/s",
    "variance": "m^2/s^2",
    "k": "m^2/s^2",
    "C": "ppm",
    "concentration_ratio": "dimensionless, C/c0"
   },
   "frame": {
    "origin": "the centre of the building's leeward face on the ground plane",
    "x": "+x streamwise (the wind blows toward +x); the building spans x in [-0.1, 0]; points at x = -0.2 ... 0.4 m",
    "y": "+y lateral; the building spans y in [-0.05, 0.05]; the z = 1/16 H plane covers y in [-0.2, 0.2]",
    "z": "+z up; roof at z = 0.2 m; points at z = 0.01 ... 0.3 m"
   },
   "counts": {
    "rows": 1652,
    "distinct_points": 876,
    "configurations": 2
   },
   "engines": {
    "openfoam12-realizableKE": "scored",
    "openlb": "pending",
    "fluidx3d": "pending",
    "ml-surrogate": "pending"
   },
   "doi": "10.5281/zenodo.15429871",
   "links": {
    "case": "https://aij.eddy3d.com/api/cases/H.json",
    "points": "https://aij.eddy3d.com/api/cases/H/points.json",
    "points_csv": "https://aij.eddy3d.com/api/cases/H/points.csv?v=ef5fafc61b8e",
    "geometry": "https://aij.eddy3d.com/api/cases/H/geometry.json",
    "geometry_stl": "https://aij.eddy3d.com/api/cases/H/geometry.stl?v=4836687efff9",
    "validation": "https://aij.eddy3d.com/api/cases/H/validation.json",
    "page": "https://aij.eddy3d.com/cases/case-h/",
    "render": "https://aij.eddy3d.com/assets/geometry/case-h.png"
   }
  },
  {
   "id": "I",
   "slug": "case-i",
   "title": "Case I — cube with a roof point source",
   "summary": "Isolated cube with an ethane point source at the centre of its roof: velocity (laser Doppler, 91 points) and concentration (hydrocarbon analyser, 539 points).",
   "configuration": {
    "building": "cube, 0.10 m on a side (= H)",
    "H_m": 0.1,
    "Re_H": 11000,
    "U_H_m_s": 1.7,
    "U_H_note": "the readme and the velocity sheet; the approach flow at z = H is 1.6969 m/s and the workbook's inflow sheet divides by 1.697",
    "wind_directions_deg": [
     0
    ],
    "source": "6 mm circular outlet at the centre of the roof (0, 0, 0.1); 10 % ethane in the mixture, 400 cc/min (= 6.67e-6 m3/s of mixture, 6.67e-7 m3/s of ethane); release velocity 0.236 m/s, M = Ve/UH = 0.14",
    "reference_concentration": "c0 = q / (UH H^2) = 39.22 ppm (39.2 in the paper), q the ETHANE flow; concentration_ratio = C / c0",
    "measurement_planes": [
     "velocity: y/H = 0 and z/H = 0.5",
     "concentration: y/H = 0 and z/H = 0 (the ground)"
    ],
    "points": {
     "velocity": 91,
     "concentration": 539
    },
    "instrument": "velocity: laser Doppler anemometer (Dantec BSA F60), 200 Hz, 240 s; concentration: hydrocarbon analyser (Kimoto HADA-01), 1 Hz, 120 s",
    "tunnel": "AIST wind tunnel, 20 m long, 3.0 × 2.0 m cross-section; approach flow described as a 1/7 power law (data paper section 3.9)",
    "scale_note": "model scale; the source states no model:full-scale ratio; Eddy3D solves it at 1:60 (a 6 m cube)"
   },
   "quantities": [
    "U",
    "V",
    "W",
    "k",
    "C",
    "concentration_ratio"
   ],
   "units": {
    "length": "m (model scale)",
    "velocity": "m/s",
    "k": "m^2/s^2",
    "C": "ppm",
    "concentration_ratio": "dimensionless, C/c0"
   },
   "frame": {
    "origin": "the centre of the cube on the ground plane",
    "x": "+x streamwise (the wind blows toward +x); the cube spans x in [-0.05, 0.05]; wind points x = -0.15 ... 0.25 m, concentration points x = 0.065 ... 2.7 m",
    "y": "+y lateral; the cube spans y in [-0.05, 0.05]; concentration points reach |y| = 0.44 m on the ground",
    "z": "+z up; roof at z = 0.1 m; the outlet at (0, 0, 0.1)"
   },
   "counts": {
    "rows": 630,
    "distinct_points": 630,
    "configurations": 2
   },
   "engines": {
    "openfoam12-realizableKE": "scored",
    "openfoam12-kEpsilon": "scored",
    "openfoam12-kOmegaSST": "scored",
    "openlb": "pending",
    "fluidx3d": "pending",
    "ml-surrogate": "pending"
   },
   "doi": "10.5281/zenodo.15430018",
   "links": {
    "case": "https://aij.eddy3d.com/api/cases/I.json",
    "points": "https://aij.eddy3d.com/api/cases/I/points.json",
    "points_csv": "https://aij.eddy3d.com/api/cases/I/points.csv?v=2864fee9eb19",
    "geometry": "https://aij.eddy3d.com/api/cases/I/geometry.json",
    "geometry_stl": "https://aij.eddy3d.com/api/cases/I/geometry.stl?v=ff61cbb22798",
    "validation": "https://aij.eddy3d.com/api/cases/I/validation.json",
    "page": "https://aij.eddy3d.com/cases/case-i/",
    "render": "https://aij.eddy3d.com/assets/geometry/case-i.png"
   }
  },
  {
   "id": "J",
   "slug": "case-j",
   "title": "Case J — 1:1:2 building, non-isothermal",
   "summary": "Isolated 1:1:2 building with a floor tracer source in an unstably stratified boundary layer: velocity, temperature, tracer concentration and their turbulent fluxes at 444 points on three planes.",
   "configuration": {
    "building": "1:1:2 (width : depth : height) prism, b = 0.08 m, H = 2b = 0.16 m",
    "b_m": 0.08,
    "H_m": 0.16,
    "Re_H": 16000,
    "U_H_m_s": 1.4581,
    "wind_directions_deg": [
     0
    ],
    "measurement_planes": [
     "vertical centre plane y/H = 0",
     "horizontal z/H = 0.025 (y <= 0 side only)",
     "horizontal z/H = 0.25"
    ],
    "points": 444,
    "stratification": "unstable: heated floor 45.8 degC, air at z = H 12.2 degC (difference 33.6 K), bulk Richardson number -0.086; building surface 22.0 .. 28.9 degC (mean 24.5 degC, 121 points in clean/cases/J/surface_temperature.csv)",
    "source": "5 mm floor outlet at (0.04, 0, 0), 0.25 H beyond the leeward wall; 5 % ethylene in air at 30.4 degC, 9.17e-6 m3/s",
    "concentration_normalisation": "c0 = 0.05 q / (U_H H^2) = 12.283 ppm (the workbook's value; the 5 % gas fraction is in it)",
    "instrument": "split-fibre hot wire (velocity), cold wire (temperature), high-speed hydrocarbon analyser (concentration), 1000 Hz, 120 s per point",
    "tunnel": "thermally stratified wind tunnel, Tokyo Polytechnic University (Atsugi); 1.2 m wide, 1.0 m high",
    "scale_note": "model scale; the sources state no model:full scale ratio"
   },
   "quantities": [
    "U",
    "V",
    "W",
    "uu",
    "vv",
    "ww",
    "k",
    "C",
    "c_rms",
    "concentration_ratio",
    "T",
    "T_rms",
    "uT",
    "vT",
    "wT"
   ],
   "units": {
    "length": "m (model scale)",
    "velocity": "m/s",
    "variance": "m^2/s^2",
    "k": "m^2/s^2",
    "concentration": "ppm of the released ethylene",
    "temperature": "degC (T); K (T_rms); heat fluxes K m/s"
   },
   "frame": {
    "origin": "the building's leeward (downwind) wall centre on the ground; x = 0 is the leeward wall",
    "x": "+x streamwise (the wind blows toward +x); the building spans x in [-0.08, 0]; the floor source is at x = +0.04",
    "y": "+y lateral; the building spans y in [-0.04, 0.04]; the z/H = 0.025 plane is measured on the y <= 0 side only",
    "z": "+z up; roof at z = 0.16; heated floor at z = 0"
   },
   "counts": {
    "rows": 444,
    "distinct_points": 444,
    "configurations": 1
   },
   "engines": {
    "openfoam12-realizableKE": "pending",
    "umf-realizableKE": "scored",
    "umf-buoyantKEpsilon": "scored",
    "openlb": "pending",
    "fluidx3d": "pending",
    "ml-surrogate": "pending"
   },
   "doi": "10.5281/zenodo.15447887",
   "links": {
    "case": "https://aij.eddy3d.com/api/cases/J.json",
    "points": "https://aij.eddy3d.com/api/cases/J/points.json",
    "points_csv": "https://aij.eddy3d.com/api/cases/J/points.csv?v=444b7aaa1791",
    "geometry": "https://aij.eddy3d.com/api/cases/J/geometry.json",
    "geometry_stl": "https://aij.eddy3d.com/api/cases/J/geometry.stl?v=1bd33d8d3531",
    "validation": "https://aij.eddy3d.com/api/cases/J/validation.json",
    "page": "https://aij.eddy3d.com/cases/case-j/",
    "render": "https://aij.eddy3d.com/assets/geometry/case-j.png"
   }
  },
  {
   "id": "K",
   "slug": "case-k",
   "title": "Case K — 9 x 9 cube array, point source",
   "summary": "9 x 9 array of 0.06 m cubes with a tracer point source on the floor between rows 2 and 3: velocity and tracer concentration at 203 points in the streets and over the first rows.",
   "configuration": {
    "array": "9 rows (along x) by 9 columns (across y) of cubes, H = 0.06 m, pitch 0.12 m (street width = H, plan area ratio 25 %); the pitch is read from the MP drawings",
    "H_m": 0.06,
    "pitch_m": 0.12,
    "cubes": 81,
    "Re_H": 9800,
    "U_H_m_s": 2.33,
    "U_H_note": "stated by the readme and data paper; the approach-flow file (Case H's) gives 2.24 m/s at z = 0.06 m",
    "wind_directions_deg": [
     0
    ],
    "measurement_planes": [
     "y/H = 0, +-1, +-2, +-3 (z up to 0.07 m)",
     "five heights from 4 mm to 70 mm; the three upper heights only on y = 0 and +-H"
    ],
    "points": 203,
    "source": "5 mm floor outlet at (-0.15, 0, 0), between rows 2 and 3 on the centre line; 100 % ethylene, 3.6e-6 m3/s",
    "concentration_normalisation": "c0 = q / (U_H H^2) = 429.18 ppm with the cube's H and U_H; the legacy workbook uses H = 0.2 m and UH = 4.94 m/s instead (C0 = 18.218 ppm), see known issues",
    "instrument": "split-fibre hot wire (velocity), high-speed hydrocarbon analyser (concentration), 1000 Hz with a 200 Hz low-pass filter, 60 s per point",
    "tunnel": "Eiffel-type wind tunnel, Tokyo Polytechnic University (Atsugi); 1.2 m wide, 1.0 m high",
    "scale_note": "model scale; the sources state no model:full scale ratio"
   },
   "quantities": [
    "U",
    "V",
    "W",
    "uu",
    "vv",
    "ww",
    "k",
    "C",
    "c_rms",
    "concentration_ratio"
   ],
   "units": {
    "length": "m (model scale)",
    "velocity": "m/s",
    "variance": "m^2/s^2",
    "k": "m^2/s^2",
    "concentration": "ppm of the released ethylene"
   },
   "frame": {
    "origin": "bottom centre of the windward wall of the 4th row of the central column: x = 0 is that wall, y = 0 the centre line of the central column",
    "x": "+x streamwise (the wind blows toward +x); row k spans x in [0.12 (k-4), 0.12 (k-4) + 0.06], so the array spans x in [-0.36, 0.66]",
    "y": "+y lateral; column centres at y = 0, +-0.12, ... +-0.48 (the array spans y in [-0.51, 0.51])",
    "z": "+z up; cube tops at z = 0.06"
   },
   "counts": {
    "rows": 203,
    "distinct_points": 203,
    "configurations": 1
   },
   "engines": {
    "openfoam12-realizableKE": "scored",
    "openlb": "pending",
    "fluidx3d": "pending",
    "ml-surrogate": "pending"
   },
   "doi": "10.5281/zenodo.15448050",
   "links": {
    "case": "https://aij.eddy3d.com/api/cases/K.json",
    "points": "https://aij.eddy3d.com/api/cases/K/points.json",
    "points_csv": "https://aij.eddy3d.com/api/cases/K/points.csv?v=8708f3251861",
    "geometry": "https://aij.eddy3d.com/api/cases/K/geometry.json",
    "geometry_stl": "https://aij.eddy3d.com/api/cases/K/geometry.stl?v=f0f8a3adfa29",
    "validation": "https://aij.eddy3d.com/api/cases/K/validation.json",
    "page": "https://aij.eddy3d.com/cases/case-k/",
    "render": "https://aij.eddy3d.com/assets/geometry/case-k.png"
   }
  },
  {
   "id": "L",
   "slug": "case-l",
   "title": "Case L — 9 x 14 cube array, line source, non-isothermal",
   "summary": "14 rows by 9 columns of 0.06 m cubes with a tracer line source on the floor across the tunnel, in an unstably stratified boundary layer: velocity, temperature, concentration and their fluxes at 344 points in the streets and over the roofs.",
   "configuration": {
    "array": "14 rows (along x) by 9 columns (across y) of cubes, H = 0.06 m, pitch 0.12 m (street width = H, plan area ratio 25 %), published as BD_caseL.stl; the data paper calls it '9 rows by 14 columns'",
    "H_m": 0.06,
    "pitch_m": 0.12,
    "cubes": 126,
    "Re_H": 5600,
    "U_H_m_s": 1.339415,
    "wind_directions_deg": [
     0
    ],
    "measurement_planes": [
     "8 heights (4 .. 150 mm) at 27 locations in the streets near the source",
     "4 heights (70 .. 150 mm) at 14 locations above the blocks",
     "3 heights (4 .. 30 mm) at 24 locations around"
    ],
    "points": 344,
    "stratification": "unstable: floor 45.0 degC, air at z = H 14.75 degC (difference 30.3 K), bulk Richardson number -0.035 (workbook; the readme says -0.04); the workbook gives the building surface as 42.2 degC",
    "source": "floor line source across the tunnel at x = -0.15 m between rows 7 and 8: readme 0.037 m x 1.2 m, BD_caseL.stl patch 0.04 m x 1.02 m; 100 % ethylene, 8.33e-6 m3/s (500 cc/min) at 35 degC",
    "concentration_normalisation": "c0 = q / (U_H H^2) = 1728.23 ppm (the workbook's value)",
    "instrument": "split-fibre hot wire (velocity), cold wire (temperature), high-speed hydrocarbon analyser (concentration), 1000 Hz with a 200 Hz low-pass filter, 60 s per point",
    "tunnel": "thermally stratified wind tunnel, Tokyo Polytechnic University (Atsugi); 1.2 m wide, 1.0 m high; 26 aluminium angles 9 mm high every 200 mm as roughness; model floor 10 mm above the tunnel floor",
    "scale_note": "model scale; the sources state no model:full scale ratio"
   },
   "quantities": [
    "U",
    "V",
    "W",
    "uu",
    "vv",
    "ww",
    "k",
    "uv",
    "uw",
    "C",
    "c_rms",
    "concentration_ratio",
    "T",
    "T_rms",
    "uc",
    "vc",
    "wc",
    "uT",
    "vT",
    "wT"
   ],
   "units": {
    "length": "m (model scale)",
    "velocity": "m/s",
    "variance": "m^2/s^2",
    "k": "m^2/s^2",
    "concentration": "ppm of the released ethylene",
    "temperature": "degC (T); K (T_rms); heat fluxes K m/s; concentration fluxes ppm m/s"
   },
   "frame": {
    "origin": "bottom centre of the windward wall of the 9th row (of 14) of the central column: x = 0 is that wall, y = 0 the centre line of the central column",
    "x": "+x streamwise (the wind blows toward +x); row k spans x in [0.12 (k-9), 0.12 (k-9) + 0.06], so the array spans x in [-0.96, 0.66]",
    "y": "+y lateral; column centres at y = 0, +-0.12, ... +-0.48 (the array spans y in [-0.51, 0.51])",
    "z": "+z up from the model floor; cube tops at z = 0.06; heated floor at z = 0"
   },
   "counts": {
    "rows": 344,
    "distinct_points": 344,
    "configurations": 1
   },
   "engines": {
    "openfoam12-realizableKE": "pending",
    "umf-realizableKE": "scored",
    "openlb": "pending",
    "fluidx3d": "pending",
    "ml-surrogate": "pending"
   },
   "doi": "10.5281/zenodo.15487637",
   "links": {
    "case": "https://aij.eddy3d.com/api/cases/L.json",
    "points": "https://aij.eddy3d.com/api/cases/L/points.json",
    "points_csv": "https://aij.eddy3d.com/api/cases/L/points.csv?v=b575fe11d107",
    "geometry": "https://aij.eddy3d.com/api/cases/L/geometry.json",
    "geometry_stl": "https://aij.eddy3d.com/api/cases/L/geometry.stl?v=20864bc75187",
    "validation": "https://aij.eddy3d.com/api/cases/L/validation.json",
    "page": "https://aij.eddy3d.com/cases/case-l/",
    "render": "https://aij.eddy3d.com/assets/geometry/case-l.png"
   }
  },
  {
   "id": "M",
   "slug": "case-m",
   "title": "Case M — TPU Atsugi campus",
   "summary": "Tracer-gas release on the Tokyo Polytechnic University Atsugi campus: 1:600 tunnel (velocity at 180°, ethylene concentration at 175°, 180° and 185°) and 18 field runs with PMCH, 15 points 3 m above ground.",
   "configuration": {
    "site": "Tokyo Polytechnic University, Atsugi campus; terrain falls from about 32 m (campus plateau) to 3.6 m at the east edge; tallest building about 32 m",
    "scale": "1:600",
    "points": 15,
    "measurement_height_m": 3,
    "measurement_height_note": "3 m above the local ground, full scale (0.005 m model)",
    "wind_directions_deg": [
     175,
     180,
     185
    ],
    "wind_direction_velocity_deg": 180,
    "field_runs": 18,
    "field_wind_directions_deg": "78 ... 200.7 (mean direction at the reference point per run); 11 of 18 within 5° of 180°",
    "reference": {
     "U_R_m_s": 4.08,
     "H_R_m_model": 0.068,
     "H_R_m_full": 41,
     "R": "rooftop of the main building: the point is 41 m above the ground, 8 m above the roof in the STL"
    },
    "tracer": {
     "tunnel": "C2H4, 100 %, 6 mm outlet, 150 cc/min = 2.5e-6 m3/s (0.09 m/s)",
     "field": "PMCH (C7F14), 200 ppm, 5 L/min, 1.5 m above ground, 25-26 Feb 2014, 18 runs of 10 min sampling"
    },
    "normalisation": "concentration ratio = C / c0, c0 = q / (U_R H_R^2): 132.5 ppm in the tunnel (the paper rounds to 1.33e2); per run in the field (1,444 ... 7,379 ppq)",
    "instrument": "tunnel: DANTEC split-fibre probe (1000 Hz, 240 s) and high-speed hydrocarbon analyser; field: sorbent tubes with GC-ECD, sonic anemometer SAT-600 at the reference point",
    "tunnel": "Eiffel-type boundary-layer wind tunnel, Tokyo Polytechnic University; cross-section 1.0 m high, 1.2 m wide; power law exponent 0.27 (AIJ Loads category IV) with an upwind taper for the topography"
   },
   "quantities": [
    "U",
    "V",
    "W",
    "uu",
    "vv",
    "ww",
    "k",
    "C",
    "c_rms",
    "concentration_ratio"
   ],
   "units": {
    "length": "m (FULL scale)",
    "velocity": "m/s (the tunnel's)",
    "variance": "m^2/s^2",
    "concentration": "ppm (the field's ppq converted)",
    "concentration_ratio": "dimensionless"
   },
   "frame": {
    "origin": "centre of the tunnel turntable on the floor plane (ground surface there at z = 33.07 m)",
    "x": "+x NORTH (full-scale metres)",
    "y": "+y WEST (compass rose of MP_caseM.png: N at +x, W at +y); the frame is right-handed",
    "z": "+z up from the TUNNEL FLOOR; the campus ground lies at z ~ 32 m"
   },
   "counts": {
    "rows": 330,
    "distinct_points": 15,
    "configurations": 22
   },
   "engines": {
    "openfoam12-realizableKE": "scored",
    "openlb": "pending",
    "fluidx3d": "pending",
    "ml-surrogate": "pending"
   },
   "doi": "10.5281/zenodo.15487857",
   "links": {
    "case": "https://aij.eddy3d.com/api/cases/M.json",
    "points": "https://aij.eddy3d.com/api/cases/M/points.json",
    "points_csv": "https://aij.eddy3d.com/api/cases/M/points.csv?v=8d32dc8f762b",
    "geometry": "https://aij.eddy3d.com/api/cases/M/geometry.json",
    "geometry_stl": "https://aij.eddy3d.com/api/cases/M/geometry.stl?v=e4e0a2044536",
    "validation": "https://aij.eddy3d.com/api/cases/M/validation.json",
    "page": "https://aij.eddy3d.com/cases/case-m/",
    "render": "https://aij.eddy3d.com/assets/geometry/case-m.png"
   }
  }
 ]
}