 "$schema": "https://aij.eddy3d.com/api/schemas/case.schema.json",
 "schema_version": "2.6.0",
 "data_version": "7ee0afb7cec8197e7edde0e7c282c8e6e9670b7cef003e6aa218c5a536817f48",
 "license": "CC-BY-4.0",
 "id": "H",
 "slug": "case-h",
 "title": "Case H — 1:1:2 building with a floor point source",
 "summary": "Isolated 1:1:2 building with an ethylene point source on the floor behind it: velocity (split-fibre hot wire) and concentration (hydrocarbon analyser) at 876 points.",
 "configuration": {
  "building": "1:1:2 (width : depth : height) prism, 0.10 × 0.10 × 0.20 m",
  "b_m": 0.1,
  "H_m": 0.2,
  "Re_H": 43000,
  "U_H_m_s": 3.226,
  "U_H_note": "the workbook's uH; the readme and the data paper state 3.23 m/s; the workbook's free-stream reference U0 is 5.279 m/s",
  "wind_directions_deg": [
   0
  ],
  "source": "4 mm hole in the floor 0.25 H = 0.05 m behind the leeward face at (0.05, 0, 0); ethylene (C2H4), 100 %, 350 cc/min = 5.83e-6 m3/s",
  "reference_concentration": "c0 = cgas q / (UH H^2) = 45.18 ppm (45.2 in the paper); concentration_ratio = C / c0",
  "measurement_planes": [
   "vertical centre plane y/H = 0",
   "horizontal z/H = 1/16 (y in [-0.2, 0.2])",
   "horizontal z/H = 1/4 and 1/2 (y in [0, 0.2])"
  ],
  "points": 876,
  "instrument": "velocity: constant-temperature anemometer (DANTEC 90C10) with a split-fibre probe (55R55, 55R56, 55R57), 1000 Hz, 120 s; concentration: high-speed total hydrocarbon analyser, 1000 Hz, 120 s",
  "tunnel": "Eiffel-type boundary-layer wind tunnel, Tokyo Polytechnic University, Atsugi (1.0 m high, 1.2 m wide)",
  "scale_note": "model scale; the source states no model:full-scale ratio; Eddy3D solves it at 1:100"
 },
 "configurations": [
  {
   "config": "default",
   "campaign": "wind_tunnel",
   "instrument": "hydrocarbon_analyser",
   "wind_direction_deg": 0.0,
   "points": 826
  },
  {
   "config": "default",
   "campaign": "wind_tunnel",
   "instrument": "split_fibre",
   "wind_direction_deg": 0.0,
   "points": 826
  }
 ],
 "quantities": [
  "U",
  "V",
  "W",
  "uu",
  "vv",
  "ww",
  "k",
  "C",
  "c_rms",
  "concentration_ratio"
 ],
 "units": {
  "length": "m (model scale)",
  "velocity": "m/s",
  "variance": "m^2/s^2",
  "k": "m^2/s^2",
  "C": "ppm",
  "concentration_ratio": "dimensionless, C/c0"
 },
 "frame": {
  "origin": "the centre of the building's leeward face on the ground plane",
  "x": "+x streamwise (the wind blows toward +x); the building spans x in [-0.1, 0]; points at x = -0.2 ... 0.4 m",
  "y": "+y lateral; the building spans y in [-0.05, 0.05]; the z = 1/16 H plane covers y in [-0.2, 0.2]",
  "z": "+z up; roof at z = 0.2 m; points at z = 0.01 ... 0.3 m",
  "lateral_sign_applied": "-1 for point numbers 1-220 (the vertical-plane sheet of the workbook), +1 elsewhere",
  "coordinate_scale_applied": 1.0
 },
 "inflow_fit": {
  "method": "log law, kappa = 0.41, least squares over z = 0.02 ... 2H on the workbook's 17-point approach profile (x = -0.493 m)",
  "u_star_m_s": 0.4065,
  "z0_mm": 7.449,
  "U_H_measured_m_s": 3.226,
  "log_law_error_at_H": "+1.1 %",
  "turbulence_intensity_at_H": 0.2165,
  "note": "derived during cleaning, not published by AIJ"
 },
 "approach_flow": {
  "source": "clean/cases/H/approach_flow.csv",
  "units": {
   "z": "m",
   "U": "m/s",
   "k": "m^2/s^2",
   "u_rms": "m/s"
  },
  "rows": [
   {
    "z": 0.01,
    "U": 0.64094168,
    "k": 0.3273025402,
    "u_rms": 0.4470913399966499
   },
   {
    "z": 0.013,
    "U": 0.81137126,
    "k": 0.3671616413,
    "u_rms": 0.46402784000531694
   },
   {
    "z": 0.025,
    "U": 1.12032528,
    "k": 0.4047311856,
    "u_rms": 0.5337416999823041
   },
   {
    "z": 0.075,
    "U": 2.5062794,
    "k": 0.4393867487,
    "u_rms": 0.6890090799837111
   },
   {
    "z": 0.125,
    "U": 2.83465394,
    "k": 0.4662370048,
    "u_rms": 0.717236580006904
   },
   {
    "z": 0.15,
    "U": 2.92859506,
    "k": 0.4415722347,
    "u_rms": 0.6843636400335716
   },
   {
    "z": 0.175,
    "U": 3.16289944,
    "k": 0.4567665656,
    "u_rms": 0.7043971000082269
   },
   {
    "z": 0.19,
    "U": 3.14489836,
    "k": 0.4339750692,
    "u_rms": 0.6859443800338333
   },
   {
    "z": 0.2,
    "U": 3.226,
    "k": 0.4520833814,
    "u_rms": 0.698461259985119
   },
   {
    "z": 0.21,
    "U": 3.26984134,
    "k": 0.4312692294,
    "u_rms": 0.6820731800180975
   },
   {
    "z": 0.225,
    "U": 3.24496888,
    "k": 0.4033782658,
    "u_rms": 0.6370704800098652
   },
   {
    "z": 0.25,
    "U": 3.48979002,
    "k": 0.4309570172,
    "u_rms": 0.6758469999933417
   },
   {
    "z": 0.3,
    "U": 3.67576892,
    "k": 0.4044189734,
    "u_rms": 0.6638140199634232
   },
   {
    "z": 0.35,
    "U": 3.87084514,
    "k": 0.379441991,
    "u_rms": 0.6509422800064534
   },
   {
    "z": 0.4,
    "U": 3.99633654,
    "k": 0.3247007712,
    "u_rms": 0.6061331399948364
   },
   {
    "z": 0.5,
    "U": 4.27112722,
    "k": 0.2525797345,
    "u_rms": 0.5177729999719954
   },
   {
    "z": 0.6,
    "U": 4.30916176,
    "k": 0.2195893036,
    "u_rms": 0.4693830000117175
   }
  ],
  "csv": {
   "url": "https://aij.eddy3d.com/api/cases/H/approach_flow.csv?v=ce516d4054a5",
   "path": "cases/H/approach_flow.csv",
   "media_type": "text/csv",
   "bytes": 821,
   "sha256": "ce516d4054a526799b327372e30e954b2adf59658c9b6eb25b2f76cf792225b0"
  }
 },
 "inflow": {
  "benchmark_data": {
   "approach_flow_csv": {
    "url": "https://aij.eddy3d.com/api/cases/H/approach_flow.csv?v=ce516d4054a5",
    "path": "cases/H/approach_flow.csv",
    "media_type": "text/csv",
    "bytes": 821,
    "sha256": "ce516d4054a526799b327372e30e954b2adf59658c9b6eb25b2f76cf792225b0"
   },
   "columns": [
    "z",
    "U",
    "k",
    "u_rms"
   ],
   "units": {
    "z": "m",
    "U": "m/s",
    "k": "m^2/s^2",
    "u_rms": "m/s"
   },
   "rows": 17,
   "fit": {
    "method": "log law, kappa = 0.41, least squares over z = 0.02 ... 2H on the workbook's 17-point approach profile (x = -0.493 m)",
    "u_star_m_s": 0.4065,
    "z0_mm": 7.449,
    "U_H_measured_m_s": 3.226,
    "log_law_error_at_H": "+1.1 %",
    "turbulence_intensity_at_H": 0.2165,
    "note": "derived during cleaning, not published by AIJ"
   },
   "note": "the measured profile and the fit of it are the benchmark's data as cleaned here; everything under `recommended` is a choice"
  },
  "recommended": {
   "status": "RECOMMENDED by this repository (not part of the benchmark): a log-law inlet fitted to the case's own approach-flow file, with k and epsilon from the standard neutral ABL relations. Any inlet may be submitted; say which in submission.yaml",
   "profile": "U(z) = u*/kappa ln((z + z0)/z0); k = u*^2 / sqrt(Cmu); epsilon = u*^3 / (kappa (z + z0))",
   "u_star_m_s": 0.4065,
   "z0_m": 0.007449,
   "kappa": 0.41,
   "Cmu": 0.09,
   "k_m2_s2": 0.5508075,
   "fit": "log law, kappa = 0.41, least squares over z = 0.02 ... 2H on the workbook's 17-point approach profile (x = -0.493 m)",
   "U_ref_m_s": 3.226,
   "z_ref_m": 0.2,
   "openfoam": "atmBoundaryLayerInletVelocity / atmBoundaryLayerInletK / atmBoundaryLayerInletEpsilon with Uref, Zref, z0 and d = 0; nutkAtmRoughWallFunction with the same z0 on the ground: cases/{id}/inflow_openfoam.txt holds them"
  },
  "flow_direction": {
   "convention": "along_x",
   "meaning": "+x is along the wind at WD = 0: flowDir (1 0 0); another WD rotates it about +z by the case's rotation sense (frame.wind_direction_rotation)",
   "wind_directions_deg": [
    0.0
   ]
  },
  "eddy3d_runs": [
   {
    "run_id": "H.openfoam12-realizableKE",
    "engine": "openfoam12-realizableKE",
    "scale": 100,
    "UhModel": 3.23,
    "UhTunnel": 3.226
   }
  ],
  "domain": "the extents, blockage and cell sizes of Eddy3D's domains are not in its snapshots and are not stated here; mesh.cells and the scale are, where the snapshot has them"
 },
 "points": {
  "url": "https://aij.eddy3d.com/api/cases/H/points.json",
  "csv": {
   "url": "https://aij.eddy3d.com/api/cases/H/points.csv?v=ef5fafc61b8e",
   "path": "cases/H/points.csv",
   "media_type": "text/csv",
   "bytes": 204220,
   "sha256": "ef5fafc61b8ea8defdec24cf23252edd1d3acdbce1daeda2295da2a31d60f06a"
  },
  "source": "clean/cases/H/points.csv",
  "rows": 1652,
  "distinct_points": 876,
  "columns": [
   "point_id",
   "config",
   "instrument",
   "wind_direction_deg",
   "x",
   "y",
   "z",
   "U",
   "V",
   "W",
   "uu",
   "vv",
   "ww",
   "k",
   "campaign",
   "C",
   "c_rms",
   "concentration_ratio"
  ],
  "counts": {
   "config": {
    "default": 1652
   },
   "instrument": {
    "hydrocarbon_analyser": 826,
    "split_fibre": 826
   },
   "wind_direction_deg": {
    "0.0": 1652
   }
  },
  "nulls": {
   "U": 826,
   "V": 826,
   "W": 826,
   "uu": 826,
   "vv": 826,
   "ww": 826,
   "k": 826,
   "C": 826,
   "c_rms": 826,
   "concentration_ratio": 826
  },
  "bbox_min": [
   -0.2,
   -0.2,
   0.01
  ],
  "bbox_max": [
   0.4,
   0.2,
   0.3
  ]
 },
 "probes": {
  "csv": {
   "url": "https://aij.eddy3d.com/api/cases/H/probes.csv?v=450e304dc11d",
   "path": "cases/H/probes.csv",
   "media_type": "text/csv",
   "bytes": 118607,
   "sha256": "450e304dc11dcebbaf627bea576b2c1850097e8ddf768d1f843f0d95fd1ecb1d"
  },
  "rows": 1652,
  "columns": [
   "point_id",
   "config",
   "campaign",
   "instrument",
   "run",
   "wind_direction_deg",
   "x",
   "y",
   "z",
   "scored_as"
  ],
  "columns_meaning": "the key columns of a scored file (point_id with config, campaign, instrument, run and wind_direction_deg as the case has them), x, y, z in m (case frame), and scored_as: the families the row is scored in (vector, k, thermistor_bracket, concentration, theta, joined by +)"
 },
 "scoring": {
  "U_ref_m_s": 3.226,
  "U_ref_meaning": "U_H, the approach speed at the building height H = 0.2 m",
  "theta": null,
  "scored_as": {
   "vector": "U, V, W and the speed |U| against the split-fibre, LDV or hot-wire components (velocity.U, velocity.V, velocity.W, speed)",
   "k": "the turbulent kinetic energy (k)",
   "thermistor_bracket": "a mean scalar speed (thermistor, cup or sonic anemometer) against |U| (vs.vector) and sqrt(|U|^2 + 2k) (vs.scalar)",
   "concentration": "the dimensionless concentration c* = C/c0 (cstar)",
   "theta": "the floor-referenced temperature fraction (theta)"
  },
  "value_columns": [
   "U",
   "V",
   "W",
   "speed",
   "k",
   "cstar",
   "theta",
   "T"
  ],
  "key_columns": [
   "config",
   "campaign",
   "instrument",
   "run",
   "wind_direction_deg",
   "point_id"
  ],
  "conventions": "velocities and the speed over U_ref, k over U_ref^2 (Cases E, F and G publish ratios already); U, V, W, |U| and the thermistor bracket scored as signed velocities (FAC2's ratio keeps the sign; hit rate D = 0.25, W = 0.05); k by the plain definitions (D = 0.25 only); a thermistor, cup or sonic reading (a mean scalar speed) scored against |U| (vs.vector) and sqrt(|U|^2 + 2k) (vs.scalar), the two ends of its bracket; c* = C/c0 with one detection limit per case, 1e-3 of the largest measured value; theta = (T_floor - T)/(T_floor - T_H) scored like a positive velocity. The same conventions score the served Eddy3D results (docs/validation/method.md).",
  "tool": "uv run python validation/score_submissions.py <folder>, from a checkout of the repository (pyproject.toml)",
  "metric_meaning": {
   "Count": "number of measured points scored",
   "MeanObserved": "mean of the measured, normalised quantity",
   "MeanPredicted": "mean of the modelled, normalised quantity",
   "Fb": "fractional bias, 2 (mean_obs - mean_pred) / (mean_obs + mean_pred); positive = model low",
   "Nmse": "normalised mean square error",
   "Nad": "normalised absolute difference",
   "Fac2": "fraction of points within a factor of two (harsh near zero for sign-changing V and W)",
   "HitRate": "fraction of points within D = 0.25 relative or W = 0.05 U_H absolute",
   "Mg": "geometric mean bias",
   "Vg": "geometric variance",
   "GeometricPairs": "pairs with both values positive (used for Mg/Vg)",
   "R": "Pearson correlation coefficient",
   "null": "a metric that is undefined for the data (for example Mg and Vg when no pair has both values positive; Fb, Nmse and Nad of a signed velocity component of Case H or I whose observed and predicted means are not both positive)"
  }
 },
 "geometry": {
  "url": "https://aij.eddy3d.com/api/cases/H/geometry.json",
  "files": [
   {
    "configuration": "default",
    "url": "https://aij.eddy3d.com/api/cases/H/geometry.stl?v=4836687efff9",
    "triangles": 12,
    "watertight": true
   }
  ]
 },
 "validation": {
  "url": "https://aij.eddy3d.com/api/cases/H/validation.json",
  "status": "scored",
  "engines": {
   "openfoam12-realizableKE": "scored",
   "openlb": "pending",
   "fluidx3d": "pending",
   "ml-surrogate": "pending"
  }
 },
 "known_issues": [
  "The table carries the legacy workbook's values (ratios at full precision x uH = 3.226 m/s), not RS_caseH.csv's: on the z/H = 1/2 and 1/4 planes (and in the approach profile) the CSV's U, V, W are the workbook ratios ROUNDED TO 0.01 before the scaling, a 0.032 m/s grid (+/-0.016 m/s).",
  "One row per instrument and point: velocity rows (split fibre) and concentration rows (hydrocarbon analyser) with the same point_id (the CSV's No.). The velocity line is x = 0.40 m and the concentration line x = 0.38 m, so 50 points have no velocity and 50 no concentration (-999.9 in the CSV); none of them is inside the building.",
  "V of the vertical-plane sheet (point numbers 1-220) is the exact negative of V at the same points in the horizontal-plane sheets (positive toward -y); it is multiplied by -1 so that V is positive toward +y everywhere, as in Cases A and D.",
  "The y = 0, z = 0.1 line (13 locations) is in two sheets and appears twice in the table, as exact copies once V is flipped; they are not independent repeat measurements.",
  "Concentration is the analyser's reading: upwind of the building (where the true value is zero) it is +/-0.1 ppm, and 97 of 826 values are negative (minimum -0.83 ppm). Log-based statistics (geometric mean, geometric variance) need a floor.",
  "The published header misspells w_rms as 'w_rsm'; the workbook's inflow sheet labels z as 'mm' but holds metres.",
  "The profile's uw and uv are published but the approach-flow table has no column for them."
 ],
 "people": {
  "data_collectors": [
   "Ryuichiro Yoshie (Tokyo Polytechnic University)",
   "Takumi Tachibana (Wind Engineering Institute)"
  ],
  "editors_distributors": [
   "Yoshihide Tominaga (Niigata Institute of Technology)",
   "Hideki Kikumoto (The University of Tokyo)",
   "Tsubasa Okaze (Institute of Science Tokyo)"
  ],
  "contact": "Ryuichiro Yoshie <yoshie@arch.t-kougei.ac.jp>"
 },
 "doi": "10.5281/zenodo.15429871",
 "doi_note": "The readme and the data paper name this one DOI; no separate version DOI is stated.",
 "citation_requested": "Yoshie, R. (2016). Wind Tunnel Experiment and Large Eddy Simulation of Pollutant/Thermal Dispersion in Non-isothermal Turbulent Boundary Layer. Adv Environ Wind Eng, 167-196. https://doi.org/10.1007/978-4-431-55912-2_9",
 "citation": {
  "apa": "Yoshie, R., Tachibana, T., Tominaga, Y., Kikumoto, H., & Okaze, T. (2025). AIJ UWE Benchmark Dataset – Case H (112C): Wind Tunnel Experiment for Flow and Dispersion around a 1:1:2 Shape Building Model [Data set]. Zenodo. https://doi.org/10.5281/zenodo.15429871",
  "bibtex": "@misc{aijuwe_case_h,\n  author    = \"Yoshie, Ryuichiro and Tachibana, Takumi and Tominaga, Yoshihide and Kikumoto, Hideki and Okaze, Tsubasa\",\n  title     = \"{AIJ UWE Benchmark Dataset -- Case H (112C): Wind Tunnel Experiment for Flow and Dispersion around a 1:1:2 Shape Building Model}\",\n  year      = \"2025\",\n  publisher = \"Zenodo\",\n  doi       = \"10.5281/zenodo.15429871\",\n  url       = \"https://doi.org/10.5281/zenodo.15429871\",\n  note      = \"Data set\"\n}"
 },
 "files_in_repository": {
  "folder": "https://github.com/Eddy3D-Dev/AIJ-Data-Validation/tree/main/raw/cases/case-h",
  "reference": "raw/cases/case-h/RS_caseH.csv",
  "approach_flow": "raw/cases/case-h/AF_caseH.csv",
  "readme": "raw/cases/case-h/readme_caseH.md"
 },
 "render": "https://aij.eddy3d.com/assets/geometry/case-h.png",
 "page": "https://aij.eddy3d.com/cases/case-h/"
}