 "$schema": "https://aij.eddy3d.com/api/schemas/case.schema.json",
 "schema_version": "2.6.0",
 "data_version": "7ee0afb7cec8197e7edde0e7c282c8e6e9670b7cef003e6aa218c5a536817f48",
 "license": "CC-BY-4.0",
 "id": "K",
 "slug": "case-k",
 "title": "Case K — 9 x 9 cube array, point source",
 "summary": "9 x 9 array of 0.06 m cubes with a tracer point source on the floor between rows 2 and 3: velocity and tracer concentration at 203 points in the streets and over the first rows.",
 "configuration": {
  "array": "9 rows (along x) by 9 columns (across y) of cubes, H = 0.06 m, pitch 0.12 m (street width = H, plan area ratio 25 %); the pitch is read from the MP drawings",
  "H_m": 0.06,
  "pitch_m": 0.12,
  "cubes": 81,
  "Re_H": 9800,
  "U_H_m_s": 2.33,
  "U_H_note": "stated by the readme and data paper; the approach-flow file (Case H's) gives 2.24 m/s at z = 0.06 m",
  "wind_directions_deg": [
   0
  ],
  "measurement_planes": [
   "y/H = 0, +-1, +-2, +-3 (z up to 0.07 m)",
   "five heights from 4 mm to 70 mm; the three upper heights only on y = 0 and +-H"
  ],
  "points": 203,
  "source": "5 mm floor outlet at (-0.15, 0, 0), between rows 2 and 3 on the centre line; 100 % ethylene, 3.6e-6 m3/s",
  "concentration_normalisation": "c0 = q / (U_H H^2) = 429.18 ppm with the cube's H and U_H; the legacy workbook uses H = 0.2 m and UH = 4.94 m/s instead (C0 = 18.218 ppm), see known issues",
  "instrument": "split-fibre hot wire (velocity), high-speed hydrocarbon analyser (concentration), 1000 Hz with a 200 Hz low-pass filter, 60 s per point",
  "tunnel": "Eiffel-type wind tunnel, Tokyo Polytechnic University (Atsugi); 1.2 m wide, 1.0 m high",
  "scale_note": "model scale; the sources state no model:full scale ratio"
 },
 "configurations": [
  {
   "config": "default",
   "campaign": "wind_tunnel",
   "instrument": "split_fibre",
   "wind_direction_deg": 0.0,
   "points": 203
  }
 ],
 "quantities": [
  "U",
  "V",
  "W",
  "uu",
  "vv",
  "ww",
  "k",
  "C",
  "c_rms",
  "concentration_ratio"
 ],
 "units": {
  "length": "m (model scale)",
  "velocity": "m/s",
  "variance": "m^2/s^2",
  "k": "m^2/s^2",
  "concentration": "ppm of the released ethylene"
 },
 "frame": {
  "origin": "bottom centre of the windward wall of the 4th row of the central column: x = 0 is that wall, y = 0 the centre line of the central column",
  "x": "+x streamwise (the wind blows toward +x); row k spans x in [0.12 (k-4), 0.12 (k-4) + 0.06], so the array spans x in [-0.36, 0.66]",
  "y": "+y lateral; column centres at y = 0, +-0.12, ... +-0.48 (the array spans y in [-0.51, 0.51])",
  "z": "+z up; cube tops at z = 0.06",
  "lateral_sign_applied": 1,
  "coordinate_scale_applied": 1.0
 },
 "inflow_fit": {
  "method": "least squares, kappa = 0.41, z = 0.02 .. 0.6 m (10 H) on AF_caseK.csv: the profile is Case H's, tabulated for a 0.2 m building, so the window is a choice",
  "u_star_m_s": 0.40706,
  "z0_mm": 7.4385,
  "U_H_measured_m_s": 2.2377,
  "U_H_stated_m_s": 2.33,
  "log_law_error_at_H": "-7.4 %",
  "log_law_rms_residual": "2.5 %",
  "note": "the file is the approach flow of Case H (identical rows); the workbook normalises it with uH = U(0.2 m) = 3.23 m/s and H = 0.2 m"
 },
 "approach_flow": {
  "source": "raw/cases/case-k/AF_caseK.csv",
  "units": {
   "z": "m",
   "U": "m/s",
   "k": "m^2/s^2",
   "u_rms": "m/s"
  },
  "rows": [
   {
    "z": 0.01,
    "U": 0.65,
    "k": 0.328,
    "u_rms": 0.448
   },
   {
    "z": 0.013,
    "U": 0.81,
    "k": 0.368,
    "u_rms": 0.465
   },
   {
    "z": 0.025,
    "U": 1.13,
    "k": 0.403,
    "u_rms": 0.532
   },
   {
    "z": 0.075,
    "U": 2.52,
    "k": 0.44,
    "u_rms": 0.69
   },
   {
    "z": 0.125,
    "U": 2.84,
    "k": 0.466,
    "u_rms": 0.716
   },
   {
    "z": 0.15,
    "U": 2.94,
    "k": 0.44,
    "u_rms": 0.684
   },
   {
    "z": 0.175,
    "U": 3.16,
    "k": 0.455,
    "u_rms": 0.703
   },
   {
    "z": 0.19,
    "U": 3.13,
    "k": 0.435,
    "u_rms": 0.687
   },
   {
    "z": 0.2,
    "U": 3.23,
    "k": 0.453,
    "u_rms": 0.7
   },
   {
    "z": 0.21,
    "U": 3.26,
    "k": 0.431,
    "u_rms": 0.681
   },
   {
    "z": 0.225,
    "U": 3.26,
    "k": 0.404,
    "u_rms": 0.636
   },
   {
    "z": 0.25,
    "U": 3.48,
    "k": 0.432,
    "u_rms": 0.677
   },
   {
    "z": 0.3,
    "U": 3.68,
    "k": 0.406,
    "u_rms": 0.665
   },
   {
    "z": 0.35,
    "U": 3.87,
    "k": 0.381,
    "u_rms": 0.652
   },
   {
    "z": 0.4,
    "U": 4.0,
    "k": 0.325,
    "u_rms": 0.606
   },
   {
    "z": 0.5,
    "U": 4.26,
    "k": 0.253,
    "u_rms": 0.519
   },
   {
    "z": 0.6,
    "U": 4.32,
    "k": 0.22,
    "u_rms": 0.471
   }
  ],
  "csv": {
   "url": "https://aij.eddy3d.com/api/cases/K/approach_flow.csv?v=5d197b5001ba",
   "path": "cases/K/approach_flow.csv",
   "media_type": "text/csv",
   "bytes": 380,
   "sha256": "5d197b5001ba9c13e463c3dbf809945b1f8194eab418d9307cf73f1f2d33ad88"
  }
 },
 "inflow": {
  "benchmark_data": {
   "approach_flow_csv": {
    "url": "https://aij.eddy3d.com/api/cases/K/approach_flow.csv?v=5d197b5001ba",
    "path": "cases/K/approach_flow.csv",
    "media_type": "text/csv",
    "bytes": 380,
    "sha256": "5d197b5001ba9c13e463c3dbf809945b1f8194eab418d9307cf73f1f2d33ad88"
   },
   "columns": [
    "z",
    "U",
    "k",
    "u_rms"
   ],
   "units": {
    "z": "m",
    "U": "m/s",
    "k": "m^2/s^2",
    "u_rms": "m/s"
   },
   "rows": 17,
   "fit": {
    "method": "least squares, kappa = 0.41, z = 0.02 .. 0.6 m (10 H) on AF_caseK.csv: the profile is Case H's, tabulated for a 0.2 m building, so the window is a choice",
    "u_star_m_s": 0.40706,
    "z0_mm": 7.4385,
    "U_H_measured_m_s": 2.2377,
    "U_H_stated_m_s": 2.33,
    "log_law_error_at_H": "-7.4 %",
    "log_law_rms_residual": "2.5 %",
    "note": "the file is the approach flow of Case H (identical rows); the workbook normalises it with uH = U(0.2 m) = 3.23 m/s and H = 0.2 m"
   },
   "note": "the measured profile and the fit of it are the benchmark's data as cleaned here; everything under `recommended` is a choice"
  },
  "recommended": {
   "status": "RECOMMENDED by this repository (not part of the benchmark): a log-law inlet fitted to the case's own approach-flow file, with k and epsilon from the standard neutral ABL relations. Any inlet may be submitted; say which in submission.yaml",
   "profile": "U(z) = u*/kappa ln((z + z0)/z0); k = u*^2 / sqrt(Cmu); epsilon = u*^3 / (kappa (z + z0))",
   "u_star_m_s": 0.40706,
   "z0_m": 0.007438500000000001,
   "kappa": 0.41,
   "Cmu": 0.09,
   "k_m2_s2": 0.5523261453333332,
   "fit": "least squares, kappa = 0.41, z = 0.02 .. 0.6 m (10 H) on AF_caseK.csv: the profile is Case H's, tabulated for a 0.2 m building, so the window is a choice",
   "U_ref_m_s": 2.33,
   "z_ref_m": 0.06,
   "openfoam": "atmBoundaryLayerInletVelocity / atmBoundaryLayerInletK / atmBoundaryLayerInletEpsilon with Uref, Zref, z0 and d = 0; nutkAtmRoughWallFunction with the same z0 on the ground: cases/{id}/inflow_openfoam.txt holds them"
  },
  "flow_direction": {
   "convention": "along_x",
   "meaning": "+x is along the wind at WD = 0: flowDir (1 0 0); another WD rotates it about +z by the case's rotation sense (frame.wind_direction_rotation)",
   "wind_directions_deg": [
    0.0
   ]
  },
  "eddy3d_runs": [
   {
    "run_id": "K.openfoam12-realizableKE",
    "engine": "openfoam12-realizableKE",
    "scale": 100,
    "inflow.z0.fullScaleM": 1.3511,
    "inflow.speedAtHeight.mPerS": 3.23,
    "inflow.height.fullScaleM": 20,
    "mesh.cells": 972637
   }
  ],
  "domain": "the extents, blockage and cell sizes of Eddy3D's domains are not in its snapshots and are not stated here; mesh.cells and the scale are, where the snapshot has them"
 },
 "points": {
  "url": "https://aij.eddy3d.com/api/cases/K/points.json",
  "csv": {
   "url": "https://aij.eddy3d.com/api/cases/K/points.csv?v=8708f3251861",
   "path": "cases/K/points.csv",
   "media_type": "text/csv",
   "bytes": 32978,
   "sha256": "8708f3251861d675fcfe23d03d238885bae813003f65372430b5ee0cfd60f3d6"
  },
  "source": "clean/cases/K/points.csv",
  "rows": 203,
  "distinct_points": 203,
  "columns": [
   "point_id",
   "config",
   "instrument",
   "wind_direction_deg",
   "x",
   "y",
   "z",
   "U",
   "V",
   "W",
   "uu",
   "vv",
   "ww",
   "k",
   "campaign",
   "C",
   "c_rms",
   "concentration_ratio"
  ],
  "counts": {
   "config": {
    "default": 203
   },
   "instrument": {
    "split_fibre": 203
   },
   "wind_direction_deg": {
    "0.0": 203
   }
  },
  "nulls": {},
  "bbox_min": [
   -0.15,
   -0.18,
   0.004
  ],
  "bbox_max": [
   0.33,
   0.18,
   0.07
  ]
 },
 "probes": {
  "csv": {
   "url": "https://aij.eddy3d.com/api/cases/K/probes.csv?v=16f8836953ce",
   "path": "cases/K/probes.csv",
   "media_type": "text/csv",
   "bytes": 15746,
   "sha256": "16f8836953ceb02eeb32a05b16bfa4d0d37c2d5f2b5d9ac957a17e057ba83b2f"
  },
  "rows": 203,
  "columns": [
   "point_id",
   "config",
   "campaign",
   "instrument",
   "run",
   "wind_direction_deg",
   "x",
   "y",
   "z",
   "scored_as"
  ],
  "columns_meaning": "the key columns of a scored file (point_id with config, campaign, instrument, run and wind_direction_deg as the case has them), x, y, z in m (case frame), and scored_as: the families the row is scored in (vector, k, thermistor_bracket, concentration, theta, joined by +)"
 },
 "scoring": {
  "U_ref_m_s": 2.33,
  "U_ref_meaning": "the stated U_H",
  "theta": null,
  "scored_as": {
   "vector": "U, V, W and the speed |U| against the split-fibre, LDV or hot-wire components (velocity.U, velocity.V, velocity.W, speed)",
   "k": "the turbulent kinetic energy (k)",
   "thermistor_bracket": "a mean scalar speed (thermistor, cup or sonic anemometer) against |U| (vs.vector) and sqrt(|U|^2 + 2k) (vs.scalar)",
   "concentration": "the dimensionless concentration c* = C/c0 (cstar)",
   "theta": "the floor-referenced temperature fraction (theta)"
  },
  "value_columns": [
   "U",
   "V",
   "W",
   "speed",
   "k",
   "cstar",
   "theta",
   "T"
  ],
  "key_columns": [
   "config",
   "campaign",
   "instrument",
   "run",
   "wind_direction_deg",
   "point_id"
  ],
  "conventions": "velocities and the speed over U_ref, k over U_ref^2 (Cases E, F and G publish ratios already); U, V, W, |U| and the thermistor bracket scored as signed velocities (FAC2's ratio keeps the sign; hit rate D = 0.25, W = 0.05); k by the plain definitions (D = 0.25 only); a thermistor, cup or sonic reading (a mean scalar speed) scored against |U| (vs.vector) and sqrt(|U|^2 + 2k) (vs.scalar), the two ends of its bracket; c* = C/c0 with one detection limit per case, 1e-3 of the largest measured value; theta = (T_floor - T)/(T_floor - T_H) scored like a positive velocity. The same conventions score the served Eddy3D results (docs/validation/method.md).",
  "tool": "uv run python validation/score_submissions.py <folder>, from a checkout of the repository (pyproject.toml)",
  "metric_meaning": {
   "Count": "number of measured points scored",
   "MeanObserved": "mean of the measured, normalised quantity",
   "MeanPredicted": "mean of the modelled, normalised quantity",
   "Fb": "fractional bias, 2 (mean_obs - mean_pred) / (mean_obs + mean_pred); positive = model low",
   "Nmse": "normalised mean square error",
   "Nad": "normalised absolute difference",
   "Fac2": "fraction of points within a factor of two (harsh near zero for sign-changing V and W)",
   "HitRate": "fraction of points within D = 0.25 relative or W = 0.05 U_H absolute",
   "Mg": "geometric mean bias",
   "Vg": "geometric variance",
   "GeometricPairs": "pairs with both values positive (used for Mg/Vg)",
   "R": "Pearson correlation coefficient",
   "null": "a metric that is undefined for the data (for example Mg and Vg when no pair has both values positive; Fb, Nmse and Nad of a signed velocity component of Case H or I whose observed and predicted means are not both positive)"
  }
 },
 "geometry": {
  "url": "https://aij.eddy3d.com/api/cases/K/geometry.json",
  "files": [
   {
    "configuration": "default",
    "url": "https://aij.eddy3d.com/api/cases/K/geometry.stl?v=f0f8a3adfa29",
    "triangles": 972,
    "watertight": true
   }
  ]
 },
 "validation": {
  "url": "https://aij.eddy3d.com/api/cases/K/validation.json",
  "status": "scored",
  "engines": {
   "openfoam12-realizableKE": "scored",
   "openlb": "pending",
   "fluidx3d": "pending",
   "ml-surrogate": "pending"
  }
 },
 "known_issues": [
  "The legacy workbook normalises with H = 0.2 m (Case H's building), UH = 4.94009 m/s and C0 = 18.218 ppm, not the cube's H = 0.06 m and U_H = 2.33 m/s; its normalised columns are 23.6 times smaller in concentration. The API's concentration_ratio uses the cube's c0 = 429.18 ppm.",
  "RS_caseK.csv has no point numbers; point_id is the row order of the file.",
  "The published CSV is the workbook rounded (3 decimals, concentrations 2), with k recomputed from the rounded rms values; the table is rebuilt from the workbook.",
  "AF_caseK.csv is Case H's approach-flow file, row for row (x = -0.493 m, tabulated for a 0.2 m building); it gives 2.24 m/s at z = 0.06 m against the stated U_H = 2.33.",
  "The lateral velocity V is dominated by a cross-flow offset (about 0.06 m/s, also in the empty tunnel); the +y and -y halves cannot confirm its sign.",
  "The mean concentration is not mirror-symmetric (the +y and -y values of one point differ by 44 % on average), so the mirror pairs are not a repeatability estimate; velocity and k are (3 % and 5 %).",
  "The workbook's <usc> / sigma_usc ('velocity magnitude', never below |U|) is not in the table.",
  "Data paper section 3.11 describes the measurements as 'approximately 30 points at eight heights downwind of the line source'; Case K has 203 points at five heights and a point source.",
  "Workbook units: x and y in millimetres in both data sheets; z in millimetres in 'Measurement data' but metres in 'Inflow'."
 ],
 "people": {
  "data_collectors": [
   "Ryuichiro Yoshie (Tokyo Polytechnic University)",
   "Takumi Tachibana (Wind Engineering Institute)"
  ],
  "editors_distributors": [
   "Yoshihide Tominaga (Niigata Institute of Technology)",
   "Hideki Kikumoto (The University of Tokyo)",
   "Tsubasa Okaze (Institute of Science Tokyo)"
  ],
  "contact": "Ryuichiro Yoshie <yoshie@arch.t-kougei.ac.jp>"
 },
 "doi": "10.5281/zenodo.15448050",
 "doi_note": null,
 "citation_requested": "Yoshie, R. (2016). Wind Tunnel Experiment and Large Eddy Simulation of Pollutant/Thermal Dispersion in Non-isothermal Turbulent Boundary Layer. Adv Environ Wind Eng, 167-196. https://doi.org/10.1007/978-4-431-55912-2_9",
 "citation": {
  "apa": "Yoshie, R., Tachibana, T., Tominaga, Y., Kikumoto, H., & Okaze, T. (2025). AIJ UWE Benchmark Dataset – Case K (ArraysC): Wind and Concentration Measurements in Cube Arrays with Point-source Dispersion [Data set]. Zenodo. https://doi.org/10.5281/zenodo.15448050",
  "bibtex": "@misc{aijuwe_case_k,\n  author    = \"Yoshie, Ryuichiro and Tachibana, Takumi and Tominaga, Yoshihide and Kikumoto, Hideki and Okaze, Tsubasa\",\n  title     = \"{AIJ UWE Benchmark Dataset -- Case K (ArraysC): Wind and Concentration Measurements in Cube Arrays with Point-source Dispersion}\",\n  year      = \"2025\",\n  publisher = \"Zenodo\",\n  doi       = \"10.5281/zenodo.15448050\",\n  url       = \"https://doi.org/10.5281/zenodo.15448050\",\n  note      = \"Data set\"\n}"
 },
 "files_in_repository": {
  "folder": "https://github.com/Eddy3D-Dev/AIJ-Data-Validation/tree/main/raw/cases/case-k",
  "reference": "raw/cases/case-k/RS_caseK.csv",
  "approach_flow": "raw/cases/case-k/AF_caseK.csv",
  "readme": "raw/cases/case-k/readme_caseK.md"
 },
 "render": "https://aij.eddy3d.com/assets/geometry/case-k.png",
 "page": "https://aij.eddy3d.com/cases/case-k/"
}