 "$schema": "https://aij.eddy3d.com/api/schemas/case.schema.json",
 "schema_version": "2.6.0",
 "data_version": "7ee0afb7cec8197e7edde0e7c282c8e6e9670b7cef003e6aa218c5a536817f48",
 "license": "CC-BY-4.0",
 "id": "M",
 "slug": "case-m",
 "title": "Case M — TPU Atsugi campus",
 "summary": "Tracer-gas release on the Tokyo Polytechnic University Atsugi campus: 1:600 tunnel (velocity at 180°, ethylene concentration at 175°, 180° and 185°) and 18 field runs with PMCH, 15 points 3 m above ground.",
 "configuration": {
  "site": "Tokyo Polytechnic University, Atsugi campus; terrain falls from about 32 m (campus plateau) to 3.6 m at the east edge; tallest building about 32 m",
  "scale": "1:600",
  "points": 15,
  "measurement_height_m": 3,
  "measurement_height_note": "3 m above the local ground, full scale (0.005 m model)",
  "wind_directions_deg": [
   175,
   180,
   185
  ],
  "wind_direction_velocity_deg": 180,
  "field_runs": 18,
  "field_wind_directions_deg": "78 ... 200.7 (mean direction at the reference point per run); 11 of 18 within 5° of 180°",
  "reference": {
   "U_R_m_s": 4.08,
   "H_R_m_model": 0.068,
   "H_R_m_full": 41,
   "R": "rooftop of the main building: the point is 41 m above the ground, 8 m above the roof in the STL"
  },
  "tracer": {
   "tunnel": "C2H4, 100 %, 6 mm outlet, 150 cc/min = 2.5e-6 m3/s (0.09 m/s)",
   "field": "PMCH (C7F14), 200 ppm, 5 L/min, 1.5 m above ground, 25-26 Feb 2014, 18 runs of 10 min sampling"
  },
  "normalisation": "concentration ratio = C / c0, c0 = q / (U_R H_R^2): 132.5 ppm in the tunnel (the paper rounds to 1.33e2); per run in the field (1,444 ... 7,379 ppq)",
  "instrument": "tunnel: DANTEC split-fibre probe (1000 Hz, 240 s) and high-speed hydrocarbon analyser; field: sorbent tubes with GC-ECD, sonic anemometer SAT-600 at the reference point",
  "tunnel": "Eiffel-type boundary-layer wind tunnel, Tokyo Polytechnic University; cross-section 1.0 m high, 1.2 m wide; power law exponent 0.27 (AIJ Loads category IV) with an upwind taper for the topography"
 },
 "configurations": [
  {
   "config": "default",
   "campaign": "wind_tunnel",
   "instrument": "hydrocarbon_analyser",
   "wind_direction_deg": 175.0,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "wind_tunnel",
   "instrument": "hydrocarbon_analyser",
   "wind_direction_deg": 180.0,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "wind_tunnel",
   "instrument": "hydrocarbon_analyser",
   "wind_direction_deg": 185.0,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "9",
   "wind_direction_deg": 78.0,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "10",
   "wind_direction_deg": 115.6666667,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "1",
   "wind_direction_deg": 132.6,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "2",
   "wind_direction_deg": 144.0,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "11",
   "wind_direction_deg": 173.6666667,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "3",
   "wind_direction_deg": 175.0,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "13",
   "wind_direction_deg": 175.9,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "12",
   "wind_direction_deg": 176.7,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "15",
   "wind_direction_deg": 178.6,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "5",
   "wind_direction_deg": 179.6,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "14",
   "wind_direction_deg": 179.7,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "8",
   "wind_direction_deg": 180.3,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "4",
   "wind_direction_deg": 181.3,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "16",
   "wind_direction_deg": 181.9,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "7",
   "wind_direction_deg": 183.3,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "6",
   "wind_direction_deg": 184.3,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "17",
   "wind_direction_deg": 194.2,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "field",
   "instrument": "sorbent_gc_ecd",
   "run": "18",
   "wind_direction_deg": 200.7,
   "points": 15
  },
  {
   "config": "default",
   "campaign": "wind_tunnel",
   "instrument": "split_fibre",
   "wind_direction_deg": 180.0,
   "points": 15
  }
 ],
 "quantities": [
  "U",
  "V",
  "W",
  "uu",
  "vv",
  "ww",
  "k",
  "C",
  "c_rms",
  "concentration_ratio"
 ],
 "units": {
  "length": "m (FULL scale)",
  "velocity": "m/s (the tunnel's)",
  "variance": "m^2/s^2",
  "concentration": "ppm (the field's ppq converted)",
  "concentration_ratio": "dimensionless"
 },
 "frame": {
  "origin": "centre of the tunnel turntable on the floor plane (ground surface there at z = 33.07 m)",
  "x": "+x NORTH (full-scale metres)",
  "y": "+y WEST (compass rose of MP_caseM.png: N at +x, W at +y); the frame is right-handed",
  "z": "+z up from the TUNNEL FLOOR; the campus ground lies at z ~ 32 m",
  "wind_direction_rotation": "meteorological FROM-direction, so 180° blows toward +x; flow_dir = (-cos WD, +sin WD), and a larger WD turns the plume toward -y. Measured on the tunnel's 175 / 180 / 185° and on the 18 field runs.",
  "lateral_sign_applied": 1,
  "coordinate_scale_applied": 600.0
 },
 "inflow_fit": {
  "method": "power law on the workbook's 40 heights (z 0.005 ... 0.6 m model) at x = -0.498 m; the data paper states exponent 0.27",
  "power_law_exponent_fitted": 0.272,
  "power_law_exponent_paper": 0.27,
  "U_at_R_height_m_s": 3.94,
  "U_R_m_s": 4.08,
  "note": "z is height above the empty tunnel floor; at the profile station the model's taper is already 0.052 m high, so the 10 lowest heights lie below it"
 },
 "approach_flow": {
  "source": "raw/cases/case-m/AF_caseM.csv",
  "units": {
   "z": "m",
   "U": "m/s",
   "k": "m^2/s^2",
   "u_rms": "m/s"
  },
  "rows": [
   {
    "z": 3.0,
    "U": 1.23,
    "k": 0.49,
    "u_rms": 0.61
   },
   {
    "z": 6.0,
    "U": 1.41,
    "k": 0.6,
    "u_rms": 0.66
   },
   {
    "z": 9.0,
    "U": 1.68,
    "k": 0.69,
    "u_rms": 0.72
   },
   {
    "z": 12.0,
    "U": 2.0,
    "k": 0.74,
    "u_rms": 0.79
   },
   {
    "z": 15.0,
    "U": 2.34,
    "k": 0.79,
    "u_rms": 0.85
   },
   {
    "z": 18.0,
    "U": 2.68,
    "k": 0.79,
    "u_rms": 0.91
   },
   {
    "z": 21.000000000000004,
    "U": 2.84,
    "k": 0.72,
    "u_rms": 0.87
   },
   {
    "z": 24.0,
    "U": 3.09,
    "k": 0.71,
    "u_rms": 0.86
   },
   {
    "z": 27.0,
    "U": 3.15,
    "k": 0.67,
    "u_rms": 0.86
   },
   {
    "z": 30.0,
    "U": 3.12,
    "k": 0.63,
    "u_rms": 0.82
   },
   {
    "z": 36.0,
    "U": 3.32,
    "k": 0.63,
    "u_rms": 0.81
   },
   {
    "z": 42.00000000000001,
    "U": 3.54,
    "k": 0.69,
    "u_rms": 0.86
   },
   {
    "z": 48.0,
    "U": 3.68,
    "k": 0.66,
    "u_rms": 0.81
   },
   {
    "z": 54.0,
    "U": 3.74,
    "k": 0.68,
    "u_rms": 0.85
   },
   {
    "z": 60.0,
    "U": 3.83,
    "k": 0.64,
    "u_rms": 0.81
   },
   {
    "z": 72.0,
    "U": 3.92,
    "k": 0.68,
    "u_rms": 0.84
   },
   {
    "z": 84.00000000000001,
    "U": 4.11,
    "k": 0.68,
    "u_rms": 0.84
   },
   {
    "z": 96.0,
    "U": 4.25,
    "k": 0.67,
    "u_rms": 0.82
   },
   {
    "z": 108.0,
    "U": 4.36,
    "k": 0.69,
    "u_rms": 0.85
   },
   {
    "z": 120.0,
    "U": 4.39,
    "k": 0.69,
    "u_rms": 0.84
   },
   {
    "z": 132.0,
    "U": 4.49,
    "k": 0.69,
    "u_rms": 0.85
   },
   {
    "z": 144.0,
    "U": 4.67,
    "k": 0.65,
    "u_rms": 0.81
   },
   {
    "z": 156.0,
    "U": 4.7,
    "k": 0.66,
    "u_rms": 0.84
   },
   {
    "z": 168.00000000000003,
    "U": 4.91,
    "k": 0.63,
    "u_rms": 0.82
   },
   {
    "z": 180.0,
    "U": 4.88,
    "k": 0.63,
    "u_rms": 0.8
   },
   {
    "z": 192.0,
    "U": 4.98,
    "k": 0.61,
    "u_rms": 0.81
   },
   {
    "z": 204.00000000000003,
    "U": 5.09,
    "k": 0.62,
    "u_rms": 0.82
   },
   {
    "z": 216.0,
    "U": 5.24,
    "k": 0.54,
    "u_rms": 0.74
   },
   {
    "z": 228.0,
    "U": 5.29,
    "k": 0.52,
    "u_rms": 0.75
   },
   {
    "z": 240.0,
    "U": 5.38,
    "k": 0.5,
    "u_rms": 0.72
   },
   {
    "z": 252.0,
    "U": 5.43,
    "k": 0.49,
    "u_rms": 0.7
   },
   {
    "z": 264.0,
    "U": 5.45,
    "k": 0.46,
    "u_rms": 0.67
   },
   {
    "z": 276.0,
    "U": 5.58,
    "k": 0.43,
    "u_rms": 0.64
   },
   {
    "z": 288.0,
    "U": 5.61,
    "k": 0.39,
    "u_rms": 0.6
   },
   {
    "z": 300.0,
    "U": 5.61,
    "k": 0.38,
    "u_rms": 0.59
   },
   {
    "z": 312.0,
    "U": 5.72,
    "k": 0.34,
    "u_rms": 0.54
   },
   {
    "z": 324.0,
    "U": 5.67,
    "k": 0.36,
    "u_rms": 0.57
   },
   {
    "z": 336.00000000000006,
    "U": 5.68,
    "k": 0.34,
    "u_rms": 0.54
   },
   {
    "z": 348.0,
    "U": 5.66,
    "k": 0.32,
    "u_rms": 0.52
   },
   {
    "z": 360.0,
    "U": 5.65,
    "k": 0.33,
    "u_rms": 0.53
   }
  ],
  "csv": {
   "url": "https://aij.eddy3d.com/api/cases/M/approach_flow.csv?v=0042caa39493",
   "path": "cases/M/approach_flow.csv",
   "media_type": "text/csv",
   "bytes": 903,
   "sha256": "0042caa394930c19454a0b2667dbda1e2a762641d7d57f443329e1088eb376ee"
  }
 },
 "inflow": {
  "benchmark_data": {
   "approach_flow_csv": {
    "url": "https://aij.eddy3d.com/api/cases/M/approach_flow.csv?v=0042caa39493",
    "path": "cases/M/approach_flow.csv",
    "media_type": "text/csv",
    "bytes": 903,
    "sha256": "0042caa394930c19454a0b2667dbda1e2a762641d7d57f443329e1088eb376ee"
   },
   "columns": [
    "z",
    "U",
    "k",
    "u_rms"
   ],
   "units": {
    "z": "m",
    "U": "m/s",
    "k": "m^2/s^2",
    "u_rms": "m/s"
   },
   "rows": 40,
   "fit": {
    "method": "power law on the workbook's 40 heights (z 0.005 ... 0.6 m model) at x = -0.498 m; the data paper states exponent 0.27",
    "power_law_exponent_fitted": 0.272,
    "power_law_exponent_paper": 0.27,
    "U_at_R_height_m_s": 3.94,
    "U_R_m_s": 4.08,
    "note": "z is height above the empty tunnel floor; at the profile station the model's taper is already 0.052 m high, so the 10 lowest heights lie below it"
   },
   "note": "the measured profile and the fit of it are the benchmark's data as cleaned here; everything under `recommended` is a choice"
  },
  "recommended": {
   "status": "RECOMMENDED by this repository (not part of the benchmark): no log law fits this case (inflow_fit says why); use the measured approach-flow profile as a tabulated inlet (approach_flow.csv). Any inlet may be submitted; say which in submission.yaml",
   "profile": "U(z) and, where published, k(z) tabulated from approach_flow.csv; epsilon = Cmu^0.5 k dU/dz where k is published, else from your own closure",
   "kappa": 0.41,
   "Cmu": 0.09,
   "U_ref_m_s": 4.08,
   "z_ref_m": null,
   "openfoam": "fixedProfile (OpenFOAM.org) with the table, or timeVaryingMappedFixedValue: cases/{id}/inflow_openfoam.txt holds the table"
  },
  "flow_direction": {
   "convention": "x_north_y_west",
   "meaning": "meteorological FROM-direction theta: flowDir (-cos theta, +sin theta, 0)",
   "wind_directions_deg": [
    175.0,
    180.0,
    185.0
   ]
  },
  "eddy3d_runs": [
   {
    "run_id": "M.openfoam12-realizableKE.sct03",
    "engine": "openfoam12-realizableKE",
    "inlet": "manual (AF_caseM.csv: 40 heights, 3-360 m, tunnel velocities unscaled, smooth floor)",
    "scale": 600
   },
   {
    "run_id": "M.openfoam12-realizableKE.sct05",
    "engine": "openfoam12-realizableKE",
    "inlet": "manual (AF_caseM.csv: 40 heights, 3-360 m, tunnel velocities unscaled, smooth floor)",
    "scale": 600
   },
   {
    "run_id": "M.openfoam12-realizableKE.sct07",
    "engine": "openfoam12-realizableKE",
    "inlet": "manual (AF_caseM.csv: 40 heights, 3-360 m, tunnel velocities unscaled, smooth floor)",
    "scale": 600
   }
  ],
  "domain": "the extents, blockage and cell sizes of Eddy3D's domains are not in its snapshots and are not stated here; mesh.cells and the scale are, where the snapshot has them"
 },
 "points": {
  "url": "https://aij.eddy3d.com/api/cases/M/points.json",
  "csv": {
   "url": "https://aij.eddy3d.com/api/cases/M/points.csv?v=8d32dc8f762b",
   "path": "cases/M/points.csv",
   "media_type": "text/csv",
   "bytes": 34920,
   "sha256": "8d32dc8f762bb8ae49e0b2252121df12bf2f94c98e724f252e887a368b18bb20"
  },
  "source": "clean/cases/M/points.csv",
  "rows": 330,
  "distinct_points": 15,
  "columns": [
   "point_id",
   "config",
   "instrument",
   "wind_direction_deg",
   "x",
   "y",
   "z",
   "U",
   "V",
   "W",
   "uu",
   "vv",
   "ww",
   "k",
   "campaign",
   "run",
   "C",
   "c_rms",
   "concentration_ratio"
  ],
  "counts": {
   "config": {
    "default": 330
   },
   "instrument": {
    "hydrocarbon_analyser": 45,
    "sorbent_gc_ecd": 270,
    "split_fibre": 15
   },
   "wind_direction_deg": {
    "115.6666667": 15,
    "132.6": 15,
    "144.0": 15,
    "173.6666667": 15,
    "175.0": 30,
    "175.9": 15,
    "176.7": 15,
    "178.6": 15,
    "179.6": 15,
    "179.7": 15,
    "180.0": 30,
    "180.3": 15,
    "181.3": 15,
    "181.9": 15,
    "183.3": 15,
    "184.3": 15,
    "185.0": 15,
    "194.2": 15,
    "200.7": 15,
    "78.0": 15
   }
  },
  "nulls": {
   "U": 315,
   "V": 315,
   "W": 315,
   "uu": 315,
   "vv": 315,
   "ww": 315,
   "k": 315,
   "C": 15,
   "c_rms": 285,
   "concentration_ratio": 15
  },
  "bbox_min": [
   -94.29222,
   -113.14146,
   6.6
  ],
  "bbox_max": [
   278.60814,
   96.30792,
   35.92863
  ]
 },
 "probes": {
  "csv": {
   "url": "https://aij.eddy3d.com/api/cases/M/probes.csv?v=877ae498c348",
   "path": "cases/M/probes.csv",
   "media_type": "text/csv",
   "bytes": 27943,
   "sha256": "877ae498c348fb598f1ba06c88cb4152ac9240c29b746ab9e62cc532eff56de8"
  },
  "rows": 330,
  "columns": [
   "point_id",
   "config",
   "campaign",
   "instrument",
   "run",
   "wind_direction_deg",
   "x",
   "y",
   "z",
   "scored_as"
  ],
  "columns_meaning": "the key columns of a scored file (point_id with config, campaign, instrument, run and wind_direction_deg as the case has them), x, y, z in m (case frame), and scored_as: the families the row is scored in (vector, k, thermistor_bracket, concentration, theta, joined by +)"
 },
 "scoring": {
  "U_ref_m_s": 4.08,
  "U_ref_meaning": "U_R, the tunnel's speed at the reference mast (the field rows carry their own U_R per run)",
  "theta": null,
  "scored_as": {
   "vector": "U, V, W and the speed |U| against the split-fibre, LDV or hot-wire components (velocity.U, velocity.V, velocity.W, speed)",
   "k": "the turbulent kinetic energy (k)",
   "thermistor_bracket": "a mean scalar speed (thermistor, cup or sonic anemometer) against |U| (vs.vector) and sqrt(|U|^2 + 2k) (vs.scalar)",
   "concentration": "the dimensionless concentration c* = C/c0 (cstar)",
   "theta": "the floor-referenced temperature fraction (theta)"
  },
  "value_columns": [
   "U",
   "V",
   "W",
   "speed",
   "k",
   "cstar",
   "theta",
   "T"
  ],
  "key_columns": [
   "config",
   "campaign",
   "instrument",
   "run",
   "wind_direction_deg",
   "point_id"
  ],
  "conventions": "velocities and the speed over U_ref, k over U_ref^2 (Cases E, F and G publish ratios already); U, V, W, |U| and the thermistor bracket scored as signed velocities (FAC2's ratio keeps the sign; hit rate D = 0.25, W = 0.05); k by the plain definitions (D = 0.25 only); a thermistor, cup or sonic reading (a mean scalar speed) scored against |U| (vs.vector) and sqrt(|U|^2 + 2k) (vs.scalar), the two ends of its bracket; c* = C/c0 with one detection limit per case, 1e-3 of the largest measured value; theta = (T_floor - T)/(T_floor - T_H) scored like a positive velocity. The same conventions score the served Eddy3D results (docs/validation/method.md).",
  "tool": "uv run python validation/score_submissions.py <folder>, from a checkout of the repository (pyproject.toml)",
  "metric_meaning": {
   "Count": "number of measured points scored",
   "MeanObserved": "mean of the measured, normalised quantity",
   "MeanPredicted": "mean of the modelled, normalised quantity",
   "Fb": "fractional bias, 2 (mean_obs - mean_pred) / (mean_obs + mean_pred); positive = model low",
   "Nmse": "normalised mean square error",
   "Nad": "normalised absolute difference",
   "Fac2": "fraction of points within a factor of two (harsh near zero for sign-changing V and W)",
   "HitRate": "fraction of points within D = 0.25 relative or W = 0.05 U_H absolute",
   "Mg": "geometric mean bias",
   "Vg": "geometric variance",
   "GeometricPairs": "pairs with both values positive (used for Mg/Vg)",
   "R": "Pearson correlation coefficient",
   "null": "a metric that is undefined for the data (for example Mg and Vg when no pair has both values positive; Fb, Nmse and Nad of a signed velocity component of Case H or I whose observed and predicted means are not both positive)"
  }
 },
 "geometry": {
  "url": "https://aij.eddy3d.com/api/cases/M/geometry.json",
  "files": [
   {
    "configuration": "default",
    "url": "https://aij.eddy3d.com/api/cases/M/geometry.stl?v=e4e0a2044536",
    "triangles": 43950,
    "watertight": true
   }
  ]
 },
 "validation": {
  "url": "https://aij.eddy3d.com/api/cases/M/validation.json",
  "status": "scored",
  "engines": {
   "openfoam12-realizableKE": "scored",
   "openlb": "pending",
   "fluidx3d": "pending",
   "ml-surrogate": "pending"
  }
 },
 "known_issues": [
  "Field concentrations are in ppq (1e-15 volume fraction) and the tunnel's in ppm: 1 ppq = 1e-9 ppm. The cleaned table converts the field's to ppm and carries C / c0 for both, with the run's own c0 in the field.",
  "Every field run has its own reference speed U_R, mean direction WD_R and tracer flow q (clean/manifest.json -> cases.M.extra_measurements.field_runs); the row's wind_direction_deg is WD_R.",
  "The tunnel measured velocity only at 180°; at 175° and 185° the CSV has -999.9 in all seven velocity columns.",
  "RS-WT_caseM.csv is the legacy workbook rounded (2 dp velocity, 1 dp concentration), and its k is half the sum of the 2-dp RMS values, up to 0.005 m2/s2 from the workbook's; the cleaned table carries the workbook's values.",
  "The tunnel source is on the ground in the workbook, LC_caseM.csv and the STL (readme: 'on a rooftop'); the field source was 1.5 m above ground.",
  "H_R = 41 m is the anemometer height above the ground; the main roof under the reference point is about 33 m above it. c0 uses H_R = 0.068 m (41 m / 600 = 0.06833 m would give 131.2 ppm, -1 %).",
  "The field has an ambient floor of 8 - 11 ppq at points 11 - 15 in every run (not subtracted); the tunnel's concentration has a zero offset (two negative means at point 12) and an rms floor of 7 ppm.",
  "Only 11 of the 18 field runs are within 5° of 180°, the tunnel's direction; runs 1, 2 and 9 have U_R of 1.4 - 1.8 m/s.",
  "BD_caseM.stl is MODEL scale, wound inward on its ground and roof facets, and has 21 boundary and 7 non-manifold edges (7 on the rim of the panel, 14 on 7 slivers hanging on building roofs); the served geometry.stl is multiplied by 600, re-wound outward, without the slivers and closed with a base slab down to z = -1 m.",
  "The approach-flow heights are above the empty tunnel floor: at the profile station the model's taper is 0.052 m high, above the 10 lowest profile heights."
 ],
 "people": {
  "data_collectors": [
   "Ryuichiro Yoshie (Tokyo Polytechnic University)",
   "Takumi Tachibana (Wind Engineering Institute)"
  ],
  "editors_distributors": [
   "Yoshihide Tominaga (Niigata Institute of Technology)",
   "Hideki Kikumoto (The University of Tokyo)",
   "Tsubasa Okaze (Institute of Science Tokyo)"
  ],
  "contact": "Ryuichiro Yoshie <yoshie@arch.t-kougei.ac.jp>"
 },
 "doi": "10.5281/zenodo.15487857",
 "doi_note": null,
 "citation_requested": "Tachibana, T., Yoshie, R., Nakayama, S., Kishida, T., Miyashita, K., Sasaki, R. (2022). Comparison between field measurement and wind tunnel experiments of gas dispersion in an urban area and verification of similarity law. Journal of Wind Engineering 47(3), 39-52 (in Japanese). http://dx.doi.org/10.5359/jwe.47.39",
 "citation": {
  "apa": "Yoshie, R., Tachibana, T., Tominaga, Y., Kikumoto, H., & Okaze, T. (2025). AIJ UWE Benchmark Dataset – Case M (TPU): Wind Tunnel Experiment and Field Observation for Flow and Dispersion within TPU Campus [Data set]. Zenodo. https://doi.org/10.5281/zenodo.15487857",
  "bibtex": "@misc{aijuwe_case_m,\n  author    = \"Yoshie, Ryuichiro and Tachibana, Takumi and Tominaga, Yoshihide and Kikumoto, Hideki and Okaze, Tsubasa\",\n  title     = \"{AIJ UWE Benchmark Dataset -- Case M (TPU): Wind Tunnel Experiment and Field Observation for Flow and Dispersion within TPU Campus}\",\n  year      = \"2025\",\n  publisher = \"Zenodo\",\n  doi       = \"10.5281/zenodo.15487857\",\n  url       = \"https://doi.org/10.5281/zenodo.15487857\",\n  note      = \"Data set\"\n}"
 },
 "files_in_repository": {
  "folder": "https://github.com/Eddy3D-Dev/AIJ-Data-Validation/tree/main/raw/cases/case-m",
  "reference": "raw/cases/case-m/RS-WT_caseM.csv",
  "approach_flow": "raw/cases/case-m/AF_caseM.csv",
  "readme": "raw/cases/case-m/readme_caseM.md"
 },
 "render": "https://aij.eddy3d.com/assets/geometry/case-m.png",
 "page": "https://aij.eddy3d.com/cases/case-m/"
}