Case D: validation

Contents
  1. Measurement locations
  2. Explore the points
  3. OpenFOAM 12
    1. Measured against modelled
    2. Scores
  4. OpenLB
  5. FluidX3D
  6. ML surrogate
    1. Scores
  7. Notes on every run
  8. Leaderboard

Engine status: OpenFOAM 12 scored · OpenLB not comparable · FluidX3D pending · ML surrogate scored

Nomenclature: symbols, columns and scores

Geometry, reference scales and release

  • \(H\), \(b\), \(D\) (m) — height of the building, cube, tower or tree belt; width of the building; edge of the cubes of Case C: the lengths the cases are drawn and normalised by
  • \(U_H\) (m/s) — reference speed: the mean approach-flow speed at the height \(H\) (each Data page gives the value used)
  • \(U_R\), \(H_R\), \(Z_R\) (m/s, m) — reference speed and height of a workbook: Case E, \(U_R\) at \(Z_R\) = 250 m full scale (1 m in the model); Case M, \(U_R\) and \(H_R\) at the reference point of the tunnel and of each field run
  • \(U_{\mathrm{ref}}\), \(L_{\mathrm{ref}}\) (m/s, m) — reference speed and length of a case’s normalisation: \(U_H\) and \(H\) (\(U_R\) and \(H_R\) in Case M); for the velocity ratios the approach speed at 15.9 m (Case E) or at 500 m (Case F)
  • \(U_b\) (m/s) — Case G: mean approach-flow speed at 9 m, the normalisation of its approach-flow table
  • \(q\), \(c_{\mathrm{gas}}\) (m³/s, ppm) — tracer release of the experiment: volume flow of the released gas, and its tracer content (\(10^6\) ppm when pure); \(Q\) is the source strength given to a solve
  • \(R_b\) (dimensionless) — bulk Richardson number of the heated-floor cases J and L (negative: unstable stratification)
  • \(\mathrm{Re_H}\), \(\mathrm{Re_D}\) (dimensionless) — Reynolds numbers \(U_H H/\nu\) and \(U_H D/\nu\) (\(\nu\): kinematic viscosity of air)
  • \(u_\ast\), \(z_0\), \(\kappa\) (m/s, mm, dimensionless) — friction velocity and roughness length of the log law fitted to the approach flow, and the von Kármán constant (0.41)
  • \(\mathrm{WD}\) (column wind_direction_deg; °) — wind direction (each frame says how it is counted); \(\mathrm{WD_R}\) is the mean direction of a field run at its reference point (Case M)
  • \(x\), \(y\), \(z\) (columns x, y, z; m) — coordinates in the case’s frame (\(+x\), \(+y\) and \(+z\) are the positive directions; each Data page says which way \(+x\) points), \(z\) up from the floor of the tunnel or from the ground
  • \(\mathrm{d}x\) (m) — lattice spacing of the OpenLB and FluidX3D runs, in metres or as a fraction of \(H\) (\(H/64\))
  • \(L_r\) (m) — reattachment length behind the building, read from a wake line at ground level; reported as \(L_r/H\)

Velocity and turbulence

  • \(U\), \(V\), \(W\) (columns U, V, W; m/s) — mean velocity along \(+x\), \(+y\), \(+z\); \(V\) is positive toward \(+y\) in every case
  • \(\lvert\mathbf{U}\rvert\) (m/s) — magnitude of the mean velocity vector, \(\sqrt{U^2+V^2+W^2}\)
  • \(V_{\mathrm{s}}\) (column Vs; m/s) — mean omnidirectional scalar speed of a thermistor (never a vector magnitude)
  • \(\overline{u'u'}\), \(\overline{v'v'}\), \(\overline{w'w'}\) (columns uu, vv, ww; m²/s²) — velocity variances (overbar: time average, prime: fluctuation about it)
  • \(\overline{u'v'}\), \(\overline{u'w'}\), \(\overline{v'w'}\) (columns uv, uw, vw; m²/s²) — Reynolds shear stresses
  • \(k = \tfrac{1}{2}\left(\overline{u'u'}+\overline{v'v'}+\overline{w'w'}\right)\) (column k; m²/s²) — turbulent kinetic energy
  • \(U/U_{\mathrm{ref}}\) (column velocity_ratio; dimensionless) — mean speed over the case’s reference speed (\(V_{\mathrm{s}}/U_{\mathrm{ref}}\) for a thermistor)
  • \(\sigma_{U/U_{\mathrm{ref}}}\) (column velocity_ratio_sd; dimensionless) — standard deviation of velocity_ratio over the observations behind a field value (Case F)
  • \(k/U_{\mathrm{ref}}^2\) (column k_ratio; dimensionless) — turbulent kinetic energy over the square of the reference speed, where only normalised values are published (Case G)

Concentration and temperature

  • \(C\) (column C; ppm) — mean tracer-gas concentration as published (volume fraction \(\times 10^6\) of the released gas diluted in air)
  • \(c_{\mathrm{rms}}\) (column c_rms; ppm) — root mean square of the concentration fluctuation
  • \(c_0\) (ppm) — reference concentration, defined for each case on its Data page: \(c_0 = \dfrac{c_{\mathrm{gas}}\thinspace q}{U_H H^2}\) (\(U_R H_R^2\) in the denominator in Case M)
  • \(c^\ast\) (column concentration_ratio; dimensionless) — dimensionless concentration \(c^\ast = C/c_0\); the value of a solve is \(c\thinspace U_H H^2/Q\) for its mean concentration \(c\) and its source strength \(Q\)
  • \(\mathrm{Sc_t}\) (dimensionless) — turbulent Schmidt number of a solve (0.3, 0.5 and 0.7)
  • \(T\), \(T_{\mathrm{rms}}\) (columns T, T_rms; °C, K) — mean air temperature as published (Cases J and L) and the root mean square of its fluctuation
  • \(\overline{u'c'}\), \(\overline{v'c'}\), \(\overline{w'c'}\) (columns uc, vc, wc; ppm·m/s) — turbulent concentration fluxes
  • \(\overline{u'\theta'}\), \(\overline{v'\theta'}\), \(\overline{w'\theta'}\) (columns uT, vT, wT; K·m/s) — turbulent heat fluxes (\(\theta'\): the temperature fluctuation)
  • \(\theta = \dfrac{T_f - T}{T_f - T_H}\) (dimensionless) — floor-referenced temperature the solves of Cases J and L are scored on: 0 at the floor, 1 in the approach air at \(H\); \(T_f\) is the floor temperature and \(T_H\) the temperature of the approach flow at \(H\)

Scores

  • \(n\) — number of pairs of a measured value \(o_i\) and a modelled value \(p_i\) at one point
  • \(R\) — Pearson correlation coefficient of the pairs
  • \(R^2\) — square of \(R\): share of the measured variance a linear fit to the model explains
  • \(\mathrm{FAC2}\) — fraction of pairs with \(0.5 \le p_i/o_i \le 2\)
  • \(\mathrm{FB}\) — fractional bias \(2(\overline{o}-\overline{p})/(\overline{o}+\overline{p})\), positive when the model is low
  • \(\mathrm{HR}\) (hit rate) — fraction of pairs with \(\lvert p_i-o_i\rvert/\lvert o_i\rvert \le \delta_{\mathrm{rel}}\) or \(\lvert p_i-o_i\rvert \le \delta_{\mathrm{abs}}\), where \(\delta_{\mathrm{rel}} = 0.25\) and \(\delta_{\mathrm{abs}} = 0.05\thinspace U_H\) for a velocity component
  • \(\mathrm{NMSE} = \dfrac{\overline{(o-p)^2}}{\overline{o}\thinspace \overline{p}}\) — normalised mean square error
  • \(\mathrm{NAD} = \dfrac{\overline{\lvert o-p\rvert}}{\overline{o}+\overline{p}}\) — normalised absolute difference
  • \(\mathrm{MG} = \exp\overline{(\ln o-\ln p)}\) — geometric mean bias
  • \(\mathrm{VG} = \exp\overline{(\ln o-\ln p)^2}\) — geometric variance
  • The ratio of \(\mathrm{FAC2}\) keeps its sign, so a model of the other sign than the measurement is a miss; \(\mathrm{FB}\), \(\mathrm{NMSE}\) and \(\mathrm{NAD}\) divide by the means, so they are undefined (shown as —) for a signed component unless the measured and the modelled mean are both positive
  • VDI 3783-9 calls the hit rate \(q\) and the tolerances \(D\) and \(W\); on this site those letters keep their other meanings (\(q\) the tracer release rate, \(D\) the block size of Case C, \(W\) the vertical velocity)
  • The detection limit of a concentration is one value per case, \(10^{-3}\) of the largest measured value. It sets \(\delta_{\mathrm{abs}}\) of the hit rate and the both-below rule of \(\mathrm{FAC2}\), and floors the values in \(\mathrm{MG}\) and \(\mathrm{VG}\).
  • The scores \(\mathrm{FB}\), \(\mathrm{FAC2}\), \(\mathrm{NMSE}\), \(\mathrm{NAD}\), \(\mathrm{MG}\) and \(\mathrm{VG}\) follow Chang & Hanna (2004); the hit rate follows VDI 3783-9.

Quantities scored

  • \(U\), \(V\) and \(W\) (mean velocity components) over \(U_H\)
  • \(k\) (turbulent kinetic energy) over \(U_H^2\)
  • the speed \(\lvert\mathbf{U}\rvert\) and \(\sqrt{\lvert\mathbf{U}\rvert^2+2k}\), against a thermistor’s \(V_{\mathrm{s}}\)
  • \(c^\ast = C/c_0\) (dimensionless concentration) at turbulent Schmidt numbers \(\mathrm{Sc_t}\) of 0.3, 0.5 and 0.7
  • \(\theta\) (floor-referenced temperature)

Measurement locations

Measurement points, Case D
Figure 1. Case D, measurement points: A split-fibre probe, WD 0; B thermistor on the site of the central block, \(\lvert x/H\rvert \le 0.2\); C thermistor in the streets along y beside it; D thermistor in the streets along x further out. Positions in multiples of \(H\). The split fibre stands at 33 of the 78 places of the thermistors; open dots: the 12 places where the thermistor read nothing; wind directions 0°, 22.5° and 45°.

Explore the points

model lowmodel high
Loading the points… Hover a point to see where it sits in 3D and how the model differs from the measurement; click to pin it. This needs JavaScript; the figures on this page show the same scores.

OpenFOAM 12

Status: scored

All three headings: 3.6 million cells at 1:400 on a cylinder domain, 3000 iterations, the 66 measured thermistor points and the 33 split-fibre points at \(z/H = 0.02\).

Measured against modelled

Case D, measured vs modelled
Figure 2. Case D, wind directions 0°, 22.5° and 45°: measured against modelled speed on the thermistor plane, and at the split-fibre points (0° only). The dots take the colour of their group in Figure 1.
Scores for all three headings and both instruments
  n FAC2 FB hit rate R
WD 0° · thermistor \(V_{\mathrm{s}}\) · \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\) 66 0.73 +0.21 0.48 0.80
WD 0° · thermistor \(V_{\mathrm{s}}\) · \(\lvert\mathbf{U}\rvert\) 66 0.67 +0.36 0.39 0.81
WD 22.5° · thermistor \(V_{\mathrm{s}}\) · \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\) 66 0.92 +0.05 0.67 0.80
WD 22.5° · thermistor \(V_{\mathrm{s}}\) · \(\lvert\mathbf{U}\rvert\) 66 0.82 +0.15 0.64 0.78
WD 22.5° · the same, rotation sense mirrored (control) 66 0.74 +0.05 0.36 0.40
WD 45° · thermistor \(V_{\mathrm{s}}\) · \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\) 66 0.89 +0.09 0.71 0.85
WD 45° · thermistor \(V_{\mathrm{s}}\) · \(\lvert\mathbf{U}\rvert\) 66 0.82 +0.17 0.70 0.84
WD 45° · the same, rotation sense mirrored (control) 66 0.70 +0.09 0.24 0.17
WD 0° · split fibre \(\lvert\mathbf{U}\rvert\) · \(\lvert\mathbf{U}\rvert\) 33 0.76 +0.07 0.52 0.85
WD 0° · split fibre \(U\) · \(U\) 33 0.48 +0.67 0.52 0.95
  • Thermistor plane: R 0.80–0.85 at all three headings. Split-fibre \(\lvert\mathbf{U}\rvert\): R 0.85.
  • Split-fibre points (33): \(\lvert\mathbf{U}\rvert\) FB +0.07. Thermistor (66): FB +0.21 with \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\) and +0.36 with \(\lvert\mathbf{U}\rvert\). In the tunnel the thermistor reads 1.34 times the split-fibre \(\lvert\mathbf{U}\rvert\) over the same 33 points.
  • Split-fibre streamwise \(U\): FB +0.67, R 0.95.
  • Rotation sense at 22.5° and 45°: the array is symmetric about \(y = 0\), so a wind turned toward \(+y\) and one turned toward \(-y\) give mirror-image fields. The data paper’s Figure 4 draws \(+y\).
    • Figure 4’s sense: R 0.80 and FAC2 0.92 at 22.5°; R 0.85 and FAC2 0.89 at 45°.
    • Mirrored sense (control): R 0.40 at 22.5°, 0.17 at 45°.
    • FB against the thermistor with \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\): +0.05 and +0.09.
  • At 0° the 66 thermistor values are 33 mirror pairs (33 independent values); the mirror control is equal to the score there.
  • FB is positive when the model is low.
Interpretation: Case D pattern, instruments and rotation sense
  • The pattern is right. The frame check (R above 0.5 at 0°) passes with room to spare; a prior Eddy3D attempt at this case scored R 0.10 (Known data issues).
  • Against the instrument that measures what RANS computes, the model is nearly unbiased (split-fibre \(\lvert\mathbf{U}\rvert\), FB +0.07).
  • Most of the thermistor gap is the instrument: the thermistor reads 1.34 times the split-fibre \(\lvert\mathbf{U}\rvert\) in the tunnel itself.
  • The model’s streamwise component is low (\(U\) FB +0.67, R 0.95) while its \(\lvert\mathbf{U}\rvert\) is not: more of the model’s near-ground speed is in the lateral and vertical components than the tunnel’s.
  • At 22.5° and 45° the solved fields corroborate the rotation sense that the measurements alone cannot decide. At both headings the model is also nearly unbiased against the thermistor (FB +0.05 and +0.09 with \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\)).

Scores

Score R \(R^2\) FAC2 FB Hit rate n
WD 0°, thermistor \(V_{\mathrm{s}}\) · \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\) +0.803 0.644 0.727 +0.214 0.485 66
WD 0°, thermistor \(V_{\mathrm{s}}\) · \(\lvert\mathbf{U}\rvert\) +0.811 0.658 0.667 +0.362 0.394 66
WD 0°, split fibre \(\lvert\mathbf{U}\rvert\) +0.853 0.728 0.758 +0.071 0.515 33
WD 0°, split fibre \(U\) +0.945 0.894 0.485 +0.668 0.515 33
WD 22.5°, thermistor \(V_{\mathrm{s}}\) · \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\) +0.803 0.646 0.924 +0.050 0.667 66
WD 22.5°, thermistor \(V_{\mathrm{s}}\) · \(\lvert\mathbf{U}\rvert\) +0.783 0.613 0.818 +0.154 0.636 66
WD 22.5°, rotation sense mirrored (control) +0.400 0.160 0.742 +0.050 0.364 66
WD 45°, thermistor \(V_{\mathrm{s}}\) · \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\) +0.854 0.730 0.894 +0.090 0.712 66
WD 45°, thermistor \(V_{\mathrm{s}}\) · \(\lvert\mathbf{U}\rvert\) +0.844 0.712 0.818 +0.170 0.697 66
WD 45°, rotation sense mirrored (control) +0.170 0.029 0.697 +0.090 0.242 66

OpenLB

Status: not comparable

Not scored: the case measures only at pedestrian height, \(z/H = 0.02\) (2 m full scale), 1.25 cells above the ground at the \(\mathrm{d}x = 1.6\thinspace\mathrm{m}\) of the Case A and B runs. A point is scored only where every point at its height in an empty-domain control is within 5 % of the imposed log law. In an empty domain 32 m wide and 80 m tall with Case D’s inflow on Eddy3D’s openlb-wind:1.9.3-r6 (its ground row half a cell under the domain, so 2 m is 2 m above the wall), 770–1010 m from the inlet (where the measured core sits), \(U\) at 2 m reads 0.43 (0.16–0.66) of the log law with the bounce-back ground, 0.86 (0.57–1.02) with OpenLB’s ground wall model and the rough law, and 1.01 (0.86–1.08) with the power law. With bounce-back every point is within 5 % only at 64 m, with either wall law at no height. In a domain 256 m wide, 320 m tall and 1600 m long on 1.9.3-r6, averaged over two crossings of the 2 m layer, \(U\) at 2 m reads 0.86 (0.79–0.91) with the rough law, 0.98 (0.928–1.022) with the power law and 0.44 (0.38–0.51) with bounce-back; every point is within 5 % from 19.2 m (12 cells) with the rough law and from 4.8 m (3 cells) with the power law. On the earlier 1.9.3-r4, whose bounce-back wall sat half a cell up and whose wall model’s first node a full cell up, the same domain read 1.00 (0.949–1.055) with the rough law over half a crossing, its misses on a pattern across the span.

The engine and the measurements are on the OpenLB and FluidX3D page.

FluidX3D

Status: pending

Not run yet. The case measures only at pedestrian height, \(z/H = 0.02\) (2 m full scale), 1.25 cells above the ground at \(\mathrm{d}x = 1.6\thinspace\mathrm{m}\). A point is scored only where every point at its height in an empty-domain control is within 5 % of the imposed log law. In an empty domain 96 m wide with Case D’s inflow at that lattice, 770–1010 m from the inlet (where the measured core sits), \(U\) at 2 m reads 0.96 (0.954–0.969) of the log law with FluidX3D’s ground wall function and a steady inflow, every point within 5 %, and 0.46 (0.20–0.74) with the bounce-back ground. In the 32 m wide domain of the OpenLB control the wall function reads 1.02 (0.95–1.06): at that distance the narrow domain varies across its span, as OpenLB’s does. With synthetic inlet turbulence the layer runs fast, 1.18 (1.13–1.24) in the wide domain. The runs of Cases A and B predate the wall function.

The engine and the measurements are on the OpenLB and FluidX3D page.

ML surrogate

Status: scored

Eddy3D’s Wind Predictor (the public Yel-2.0 network) predicts \(\lvert\mathbf{U_{\mathrm{mean}}}\rvert/U_{\mathrm{ref}}\) at one height, 1.8 m, so the case is scaled ×360 to put its measurement plane there; the prediction is read at the tunnel’s own sensor coordinates. How the surrogate is run is on the ML surrogate page.

Measured vs predicted, ML surrogate, Case D
Figure 3. Case D, measured vs predicted pedestrian-height speed, ML surrogate, with the 1:1 line and the factor-of-two band.
Quantity n FB FAC2 R hit rate OpenFOAM, same points and quantity
\(V_{\mathrm{s}}/U_H\), thermistor, 3 WD 198 +0.67 0.34 +0.33 0.17 WD 0°, 22.5° and 45° (66 points each): \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\) FB +0.21 / +0.05 / +0.09, FAC2 0.73 / 0.92 / 0.89, R +0.80 / +0.80 / +0.85
\(\lvert\mathbf{U}\rvert/U_H\), split fibre, WD 0 33 +0.23 0.52 +0.59 0.24 FB +0.07, FAC2 0.76, R +0.85, hit rate 0.52
  • FB is positive when the model is low. Reversing the wind changes the predicted field by at most \(1 \times 10^{-4}\) \(U_{\mathrm{ref}}\): the prediction does not depend on the wind direction.

Scores

Score R \(R^2\) FAC2 FB Hit rate n
\(V_{\mathrm{s}}\), thermistor, 3 WD +0.325 0.106 0.343 +0.673 0.167 198
\(\lvert\mathbf{U}\rvert\), split fibre, WD 0 +0.587 0.344 0.515 +0.231 0.242 33
\(V_{\mathrm{s}}\), WD 0, lattice cut at ±250 m +0.220 0.048 0.636 +0.489 0.273 66
wind reversed (control) +0.492 0.242 0.470 +0.555 0.197 66

Notes on every run

  • Normalisation: velocities by \(U_H\), \(k\) by \(U_H^2\) (the benchmark's own convention; Case E by \(U\) at 15.9 m, as it is published); hit rate \(\delta_{\mathrm{rel}} = 0.25\), \(\delta_{\mathrm{abs}} = 0.05\) in those units

Leaderboard

Rank Run Source Hit rate, \(\lvert\mathbf{U}\rvert\) Hit rate, \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\) Hit rate, \(\lvert\mathbf{U}\rvert\) Hit rate FAC2 R \(R^2\)
1 OpenFOAM 12 Eddy3D 0.515 0.621 0.576 0.571 0.791 +0.829 0.687
2 OpenFOAM simpleFoam (Eddy3D Outdoor case writer) (eddy3d-of12-nutcap-lifted) community 0.485 0.611 0.566 0.554 0.825 +0.836 0.700

All runs scored by validation/score_submissions.py. Ranked by mean hit rate (VDI 3783) over the tasks; bold: best per column. Not ranked: the ML surrogate (no point ids) and negative controls. Community rows are self-reported (Validate your own solver).