Case K: reference data

Contents
  1. Configuration
  2. Frame and units
  3. Reference data
  4. Columns
  5. Inflow
  6. Known data issues
  7. API
  8. Attribution
    1. Cite

Configuration

Parameter Value
Array 9 rows (along x) by 9 columns (across y) of cubes, \(H = 0.06\thinspace\mathrm{m}\), pitch 0.12 m (street width = H, plan area ratio 25 %); the pitch is read from the MP drawings
Height H (m) 0.06
pitch m 0.12
cubes 81
Reynolds number \(\mathrm{Re_H}\) 9800
\(U_H\) (m/s) 2.33
\(U_H\), note stated by the readme and data paper; the approach-flow file (Case H's) gives 2.24 m/s at \(z = 0.06\thinspace\mathrm{m}\)
Wind directions (°) 0
Measurement planes \(y/H = 0\), +-1, +-2, +-3 (z up to 0.07 m), five heights from 4 mm to 70 mm; the three upper heights only on \(y = 0\) and +-H
Points 203
source 5 mm floor outlet at (-0.15, 0, 0), between rows 2 and 3 on the centre line; 100 % ethylene, 3.6e-6 m³/s
concentration normalisation \(c_0 = \dfrac{q}{U_H H^2}\) = 429.18 ppm with the cube's H and \(U_H\); the legacy workbook uses \(H = 0.2\thinspace\mathrm{m}\) and \(U_H\) = 4.94 m/s instead (\(C_0\) = 18.218 ppm), see known issues
Instrument split-fibre hot wire (velocity), high-speed hydrocarbon analyser (concentration), 1000 Hz with a 200 Hz low-pass filter, 60 s per point
Wind tunnel Eiffel-type wind tunnel, Tokyo Polytechnic University (Atsugi); 1.2 m wide, 1.0 m high
Scale, note model scale; the sources state no model:full scale ratio
Nomenclature: symbols, columns and scores

Geometry, reference scales and release

  • \(H\), \(b\), \(D\) (m) — height of the building, cube, tower or tree belt; width of the building; edge of the cubes of Case C: the lengths the cases are drawn and normalised by
  • \(U_H\) (m/s) — reference speed: the mean approach-flow speed at the height \(H\) (each Data page gives the value used)
  • \(U_R\), \(H_R\), \(Z_R\) (m/s, m) — reference speed and height of a workbook: Case E, \(U_R\) at \(Z_R\) = 250 m full scale (1 m in the model); Case M, \(U_R\) and \(H_R\) at the reference point of the tunnel and of each field run
  • \(U_{\mathrm{ref}}\), \(L_{\mathrm{ref}}\) (m/s, m) — reference speed and length of a case’s normalisation: \(U_H\) and \(H\) (\(U_R\) and \(H_R\) in Case M); for the velocity ratios the approach speed at 15.9 m (Case E) or at 500 m (Case F)
  • \(U_b\) (m/s) — Case G: mean approach-flow speed at 9 m, the normalisation of its approach-flow table
  • \(q\), \(c_{\mathrm{gas}}\) (m³/s, ppm) — tracer release of the experiment: volume flow of the released gas, and its tracer content (\(10^6\) ppm when pure); \(Q\) is the source strength given to a solve
  • \(R_b\) (dimensionless) — bulk Richardson number of the heated-floor cases J and L (negative: unstable stratification)
  • \(\mathrm{Re_H}\), \(\mathrm{Re_D}\) (dimensionless) — Reynolds numbers \(U_H H/\nu\) and \(U_H D/\nu\) (\(\nu\): kinematic viscosity of air)
  • \(u_\ast\), \(z_0\), \(\kappa\) (m/s, mm, dimensionless) — friction velocity and roughness length of the log law fitted to the approach flow, and the von Kármán constant (0.41)
  • \(\mathrm{WD}\) (column wind_direction_deg; °) — wind direction (each frame says how it is counted); \(\mathrm{WD_R}\) is the mean direction of a field run at its reference point (Case M)
  • \(x\), \(y\), \(z\) (columns x, y, z; m) — coordinates in the case’s frame (\(+x\), \(+y\) and \(+z\) are the positive directions; each Data page says which way \(+x\) points), \(z\) up from the floor of the tunnel or from the ground
  • \(\mathrm{d}x\) (m) — lattice spacing of the OpenLB and FluidX3D runs, in metres or as a fraction of \(H\) (\(H/64\))
  • \(L_r\) (m) — reattachment length behind the building, read from a wake line at ground level; reported as \(L_r/H\)

Velocity and turbulence

  • \(U\), \(V\), \(W\) (columns U, V, W; m/s) — mean velocity along \(+x\), \(+y\), \(+z\); \(V\) is positive toward \(+y\) in every case
  • \(\lvert\mathbf{U}\rvert\) (m/s) — magnitude of the mean velocity vector, \(\sqrt{U^2+V^2+W^2}\)
  • \(V_{\mathrm{s}}\) (column Vs; m/s) — mean omnidirectional scalar speed of a thermistor (never a vector magnitude)
  • \(\overline{u'u'}\), \(\overline{v'v'}\), \(\overline{w'w'}\) (columns uu, vv, ww; m²/s²) — velocity variances (overbar: time average, prime: fluctuation about it)
  • \(\overline{u'v'}\), \(\overline{u'w'}\), \(\overline{v'w'}\) (columns uv, uw, vw; m²/s²) — Reynolds shear stresses
  • \(k = \tfrac{1}{2}\left(\overline{u'u'}+\overline{v'v'}+\overline{w'w'}\right)\) (column k; m²/s²) — turbulent kinetic energy
  • \(U/U_{\mathrm{ref}}\) (column velocity_ratio; dimensionless) — mean speed over the case’s reference speed (\(V_{\mathrm{s}}/U_{\mathrm{ref}}\) for a thermistor)
  • \(\sigma_{U/U_{\mathrm{ref}}}\) (column velocity_ratio_sd; dimensionless) — standard deviation of velocity_ratio over the observations behind a field value (Case F)
  • \(k/U_{\mathrm{ref}}^2\) (column k_ratio; dimensionless) — turbulent kinetic energy over the square of the reference speed, where only normalised values are published (Case G)

Concentration and temperature

  • \(C\) (column C; ppm) — mean tracer-gas concentration as published (volume fraction \(\times 10^6\) of the released gas diluted in air)
  • \(c_{\mathrm{rms}}\) (column c_rms; ppm) — root mean square of the concentration fluctuation
  • \(c_0\) (ppm) — reference concentration, defined for each case on its Data page: \(c_0 = \dfrac{c_{\mathrm{gas}}\thinspace q}{U_H H^2}\) (\(U_R H_R^2\) in the denominator in Case M)
  • \(c^\ast\) (column concentration_ratio; dimensionless) — dimensionless concentration \(c^\ast = C/c_0\); the value of a solve is \(c\thinspace U_H H^2/Q\) for its mean concentration \(c\) and its source strength \(Q\)
  • \(\mathrm{Sc_t}\) (dimensionless) — turbulent Schmidt number of a solve (0.3, 0.5 and 0.7)
  • \(T\), \(T_{\mathrm{rms}}\) (columns T, T_rms; °C, K) — mean air temperature as published (Cases J and L) and the root mean square of its fluctuation
  • \(\overline{u'c'}\), \(\overline{v'c'}\), \(\overline{w'c'}\) (columns uc, vc, wc; ppm·m/s) — turbulent concentration fluxes
  • \(\overline{u'\theta'}\), \(\overline{v'\theta'}\), \(\overline{w'\theta'}\) (columns uT, vT, wT; K·m/s) — turbulent heat fluxes (\(\theta'\): the temperature fluctuation)
  • \(\theta = \dfrac{T_f - T}{T_f - T_H}\) (dimensionless) — floor-referenced temperature the solves of Cases J and L are scored on: 0 at the floor, 1 in the approach air at \(H\); \(T_f\) is the floor temperature and \(T_H\) the temperature of the approach flow at \(H\)

Scores

  • \(n\) — number of pairs of a measured value \(o_i\) and a modelled value \(p_i\) at one point
  • \(R\) — Pearson correlation coefficient of the pairs
  • \(R^2\) — square of \(R\): share of the measured variance a linear fit to the model explains
  • \(\mathrm{FAC2}\) — fraction of pairs with \(0.5 \le p_i/o_i \le 2\)
  • \(\mathrm{FB}\) — fractional bias \(2(\overline{o}-\overline{p})/(\overline{o}+\overline{p})\), positive when the model is low
  • \(\mathrm{HR}\) (hit rate) — fraction of pairs with \(\lvert p_i-o_i\rvert/\lvert o_i\rvert \le \delta_{\mathrm{rel}}\) or \(\lvert p_i-o_i\rvert \le \delta_{\mathrm{abs}}\), where \(\delta_{\mathrm{rel}} = 0.25\) and \(\delta_{\mathrm{abs}} = 0.05\thinspace U_H\) for a velocity component
  • \(\mathrm{NMSE} = \dfrac{\overline{(o-p)^2}}{\overline{o}\thinspace \overline{p}}\) — normalised mean square error
  • \(\mathrm{NAD} = \dfrac{\overline{\lvert o-p\rvert}}{\overline{o}+\overline{p}}\) — normalised absolute difference
  • \(\mathrm{MG} = \exp\overline{(\ln o-\ln p)}\) — geometric mean bias
  • \(\mathrm{VG} = \exp\overline{(\ln o-\ln p)^2}\) — geometric variance
  • The ratio of \(\mathrm{FAC2}\) keeps its sign, so a model of the other sign than the measurement is a miss; \(\mathrm{FB}\), \(\mathrm{NMSE}\) and \(\mathrm{NAD}\) divide by the means, so they are undefined (shown as —) for a signed component unless the measured and the modelled mean are both positive
  • VDI 3783-9 calls the hit rate \(q\) and the tolerances \(D\) and \(W\); on this site those letters keep their other meanings (\(q\) the tracer release rate, \(D\) the block size of Case C, \(W\) the vertical velocity)
  • The detection limit of a concentration is one value per case, \(10^{-3}\) of the largest measured value. It sets \(\delta_{\mathrm{abs}}\) of the hit rate and the both-below rule of \(\mathrm{FAC2}\), and floors the values in \(\mathrm{MG}\) and \(\mathrm{VG}\).
  • The scores \(\mathrm{FB}\), \(\mathrm{FAC2}\), \(\mathrm{NMSE}\), \(\mathrm{NAD}\), \(\mathrm{MG}\) and \(\mathrm{VG}\) follow Chang & Hanna (2004); the hit rate follows VDI 3783-9.

Quantities scored

  • \(U\), \(V\) and \(W\) (mean velocity components) over \(U_H\)
  • \(k\) (turbulent kinetic energy) over \(U_H^2\)
  • the speed \(\lvert\mathbf{U}\rvert\) and \(\sqrt{\lvert\mathbf{U}\rvert^2+2k}\), against a thermistor’s \(V_{\mathrm{s}}\)
  • \(c^\ast = C/c_0\) (dimensionless concentration) at turbulent Schmidt numbers \(\mathrm{Sc_t}\) of 0.3, 0.5 and 0.7
  • \(\theta\) (floor-referenced temperature)

Frame and units

Property Definition
Origin bottom centre of the windward wall of the 4th row of the central column: \(x = 0\) is that wall, \(y = 0\) the centre line of the central column
x \(+x\) streamwise (the wind blows toward \(+x\)); row \(k\) spans x in [0.12 (\(k\)-4), 0.12 (\(k\)-4) + 0.06], so the array spans \(x \in \lbrack -0.36,\thinspace 0.66\rbrack\)
y \(+y\) lateral; column centres at \(y = 0\), +-0.12, … +-0.48 (the array spans \(y \in \lbrack -0.51,\thinspace 0.51\rbrack\))
z \(+z\) up; cube tops at \(z = 0.06\)
Lateral sign applied 1
Coordinate scale applied 1.0
Unit of length m (model scale)
Unit of velocity m/s
Unit of variance m²/s²
Unit of \(k\) m²/s²
Unit of concentration ppm of the released ethylene

Reference data

Source in this repository: raw/cases/case-k/RS_caseK.csv (approach flow: raw/cases/case-k/AF_caseK.csv).

The cleaned table has 203 rows over 203 distinct points; columns point_id, config, instrument, wind_direction_deg, x, y, z, U, V, W, uu, vv, ww, k, campaign, C, c_rms, concentration_ratio.

Configuration Points
default, wind tunnel, split fibre, WD 0° 203

Columns

The columns of the cleaned table (points.csv, points.json), in order.

The 18 columns and what each holds
Column Symbol Meaning
point_id   the tunnel's own measurement point number
config   configuration key: 'default', Case C centre building '0D'/'1D'/'2D', Case E state 'bc' (before) / 'ac' (after construction)
instrument   'split_fibre' (vector components) or 'thermistor' (omnidirectional scalar speed)
wind_direction_deg   AIJ wind direction in degrees; 0 is the case's reference direction (see frame)
x   m, case frame
y   m, case frame
z   m above ground, case frame
U \(U\) m/s, mean velocity along \(+x\)
V \(V\) m/s, mean velocity along \(+y\) (sign unified: positive toward \(+y\))
W \(W\) m/s, mean velocity along \(+z\)
uu \(\overline{u'u'}\) m²/s², variance of u
vv \(\overline{v'v'}\) m²/s², variance of v
ww \(\overline{w'w'}\) m²/s², variance of w
k \(k\) m²/s², turbulent kinetic energy
campaign   'wind_tunnel' (model scale) or 'field' (a full-scale observation: Cases F, G, M)
C \(C\) ppm, mean tracer-gas concentration as published (volume fraction x 1e6 of the released gas diluted in air)
c_rms \(c_{\mathrm{rms}}\) ppm, rms of the concentration fluctuation
concentration_ratio \(c^\ast\) \(C/c_0\), \(c_0 = \dfrac{q}{U_{\mathrm{ref}} L_{\mathrm{ref}}^2}\) as the benchmark defines it for the case (manifest cases.<id>.normalisation)

Inflow

Property Value
Method least squares, \(\kappa\) = 0.41, \(z = 0.02\thinspace\ldots\thinspace 0.6\thinspace\mathrm{m}\) (\(10\thinspace H\)) on AF_caseK.csv: the profile is Case H's, tabulated for a 0.2 m building, so the window is a choice
Friction velocity \(u_\ast\) (m/s) 0.40706
Roughness length \(z_0\) (mm) 7.4385
\(U_H\), measured (m/s) 2.2377
\(U\) H stated m s 2.33
Log-law error at H -7.4 %
log law rms residual 2.5 %
Note the file is the approach flow of Case H (identical rows); the workbook normalises it with \(u_H\) = \(U(0.2\text{ m})\) = 3.23 m/s and \(H = 0.2\thinspace\mathrm{m}\)

Known data issues

  • The legacy workbook normalises with \(H = 0.2\thinspace\mathrm{m}\) (Case H's building), \(U_H\) = 4.94009 m/s and \(C_0\) = 18.218 ppm, not the cube's \(H = 0.06\thinspace\mathrm{m}\) and \(U_H\) = 2.33 m/s; its normalised columns are 23.6 times smaller in concentration. The API's concentration_ratio uses the cube's \(c_0\) = 429.18 ppm.
  • RS_caseK.csv has no point numbers; point_id is the row order of the file.
  • The published CSV is the workbook rounded (3 decimals, concentrations 2), with \(k\) recomputed from the rounded rms values; the table is rebuilt from the workbook.
  • AF_caseK.csv is Case H's approach-flow file, row for row (\(x = -0.493\thinspace\mathrm{m}\), tabulated for a 0.2 m building); it gives 2.24 m/s at \(z = 0.06\thinspace\mathrm{m}\) against the stated \(U_H\) = 2.33.
  • The lateral velocity \(V\) is dominated by a cross-flow offset (about 0.06 m/s, also in the empty tunnel); the \(+y\) and -y halves cannot confirm its sign.
  • The mean concentration is not mirror-symmetric (the \(+y\) and -y values of one point differ by 44 % on average), so the mirror pairs are not a repeatability estimate; velocity and \(k\) are (3 % and 5 %).
  • The workbook's \(\langle u_{\mathrm{sc}}\rangle\) / \(\sigma_{\mathrm{usc}}\) ('velocity magnitude', never below \(\lvert\mathbf{U}\rvert\)) is not in the table.
  • Data paper section 3.11 describes the measurements as 'approximately 30 points at eight heights downwind of the line source'; Case K has 203 points at five heights and a point source.
  • Workbook units: x and y in millimetres in both data sheets; z in millimetres in 'Measurement data' but metres in 'Inflow'.

API

Attribution

  • Data collected by Ryuichiro Yoshie (Tokyo Polytechnic University) and Takumi Tachibana (Wind Engineering Institute).
  • Edited and distributed by Yoshihide Tominaga (Niigata Institute of Technology), Hideki Kikumoto (The University of Tokyo) and Tsubasa Okaze (Institute of Science Tokyo).
  • DOI: 10.5281/zenodo.15448050
  • Citation requested: Yoshie, R. (2016). Wind Tunnel Experiment and Large Eddy Simulation of Pollutant/Thermal Dispersion in Non-isothermal Turbulent Boundary Layer. Adv Environ Wind Eng, 167-196. https://doi.org/10.1007/978-4-431-55912-2_9
  • Licence: CC BY 4.0

Cite

APA

Yoshie, R., Tachibana, T., Tominaga, Y., Kikumoto, H., & Okaze, T. (2025). AIJ UWE Benchmark Dataset – Case K (ArraysC): Wind and Concentration Measurements in Cube Arrays with Point-source Dispersion [Data set]. Zenodo. https://doi.org/10.5281/zenodo.15448050

BibTeX

@misc{aijuwe_case_k,
  author    = "Yoshie, Ryuichiro and Tachibana, Takumi and Tominaga, Yoshihide and Kikumoto, Hideki and Okaze, Tsubasa",
  title     = "{AIJ UWE Benchmark Dataset -- Case K (ArraysC): Wind and Concentration Measurements in Cube Arrays with Point-source Dispersion}",
  year      = "2025",
  publisher = "Zenodo",
  doi       = "10.5281/zenodo.15448050",
  url       = "https://doi.org/10.5281/zenodo.15448050",
  note      = "Data set"
}

API: see About.