Case E: validation

Contents
  1. Measurement locations
  2. Explore the points
  3. OpenFOAM 12
    1. Measured against modelled
    2. Scores
  4. OpenLB
  5. FluidX3D
  6. ML surrogate
    1. Scores
  7. Grid uncertainty
  8. Notes on every run
  9. Leaderboard

Engine status: OpenFOAM 12 scored · OpenLB not comparable · FluidX3D pending · ML surrogate scored

Nomenclature: symbols, columns and scores

Geometry, reference scales and release

  • \(H\), \(b\), \(D\) (m) — height of the building, cube, tower or tree belt; width of the building; edge of the cubes of Case C: the lengths the cases are drawn and normalised by
  • \(U_H\) (m/s) — reference speed: the mean approach-flow speed at the height \(H\) (each Data page gives the value used)
  • \(U_R\), \(H_R\), \(Z_R\) (m/s, m) — reference speed and height of a workbook: Case E, \(U_R\) at \(Z_R\) = 250 m full scale (1 m in the model); Case M, \(U_R\) and \(H_R\) at the reference point of the tunnel and of each field run
  • \(U_{\mathrm{ref}}\), \(L_{\mathrm{ref}}\) (m/s, m) — reference speed and length of a case’s normalisation: \(U_H\) and \(H\) (\(U_R\) and \(H_R\) in Case M); for the velocity ratios the approach speed at 15.9 m (Case E) or at 500 m (Case F)
  • \(U_b\) (m/s) — Case G: mean approach-flow speed at 9 m, the normalisation of its approach-flow table
  • \(q\), \(c_{\mathrm{gas}}\) (m³/s, ppm) — tracer release of the experiment: volume flow of the released gas, and its tracer content (\(10^6\) ppm when pure); \(Q\) is the source strength given to a solve
  • \(R_b\) (dimensionless) — bulk Richardson number of the heated-floor cases J and L (negative: unstable stratification)
  • \(\mathrm{Re_H}\), \(\mathrm{Re_D}\) (dimensionless) — Reynolds numbers \(U_H H/\nu\) and \(U_H D/\nu\) (\(\nu\): kinematic viscosity of air)
  • \(u_\ast\), \(z_0\), \(\kappa\) (m/s, mm, dimensionless) — friction velocity and roughness length of the log law fitted to the approach flow, and the von Kármán constant (0.41)
  • \(\mathrm{WD}\) (column wind_direction_deg; °) — wind direction (each frame says how it is counted); \(\mathrm{WD_R}\) is the mean direction of a field run at its reference point (Case M)
  • \(x\), \(y\), \(z\) (columns x, y, z; m) — coordinates in the case’s frame (\(+x\), \(+y\) and \(+z\) are the positive directions; each Data page says which way \(+x\) points), \(z\) up from the floor of the tunnel or from the ground
  • \(\mathrm{d}x\) (m) — lattice spacing of the OpenLB and FluidX3D runs, in metres or as a fraction of \(H\) (\(H/64\))
  • \(L_r\) (m) — reattachment length behind the building, read from a wake line at ground level; reported as \(L_r/H\)

Velocity and turbulence

  • \(U\), \(V\), \(W\) (columns U, V, W; m/s) — mean velocity along \(+x\), \(+y\), \(+z\); \(V\) is positive toward \(+y\) in every case
  • \(\lvert\mathbf{U}\rvert\) (m/s) — magnitude of the mean velocity vector, \(\sqrt{U^2+V^2+W^2}\)
  • \(V_{\mathrm{s}}\) (column Vs; m/s) — mean omnidirectional scalar speed of a thermistor (never a vector magnitude)
  • \(\overline{u'u'}\), \(\overline{v'v'}\), \(\overline{w'w'}\) (columns uu, vv, ww; m²/s²) — velocity variances (overbar: time average, prime: fluctuation about it)
  • \(\overline{u'v'}\), \(\overline{u'w'}\), \(\overline{v'w'}\) (columns uv, uw, vw; m²/s²) — Reynolds shear stresses
  • \(k = \tfrac{1}{2}\left(\overline{u'u'}+\overline{v'v'}+\overline{w'w'}\right)\) (column k; m²/s²) — turbulent kinetic energy
  • \(U/U_{\mathrm{ref}}\) (column velocity_ratio; dimensionless) — mean speed over the case’s reference speed (\(V_{\mathrm{s}}/U_{\mathrm{ref}}\) for a thermistor)
  • \(\sigma_{U/U_{\mathrm{ref}}}\) (column velocity_ratio_sd; dimensionless) — standard deviation of velocity_ratio over the observations behind a field value (Case F)
  • \(k/U_{\mathrm{ref}}^2\) (column k_ratio; dimensionless) — turbulent kinetic energy over the square of the reference speed, where only normalised values are published (Case G)

Concentration and temperature

  • \(C\) (column C; ppm) — mean tracer-gas concentration as published (volume fraction \(\times 10^6\) of the released gas diluted in air)
  • \(c_{\mathrm{rms}}\) (column c_rms; ppm) — root mean square of the concentration fluctuation
  • \(c_0\) (ppm) — reference concentration, defined for each case on its Data page: \(c_0 = \dfrac{c_{\mathrm{gas}}\thinspace q}{U_H H^2}\) (\(U_R H_R^2\) in the denominator in Case M)
  • \(c^\ast\) (column concentration_ratio; dimensionless) — dimensionless concentration \(c^\ast = C/c_0\); the value of a solve is \(c\thinspace U_H H^2/Q\) for its mean concentration \(c\) and its source strength \(Q\)
  • \(\mathrm{Sc_t}\) (dimensionless) — turbulent Schmidt number of a solve (0.3, 0.5 and 0.7)
  • \(T\), \(T_{\mathrm{rms}}\) (columns T, T_rms; °C, K) — mean air temperature as published (Cases J and L) and the root mean square of its fluctuation
  • \(\overline{u'c'}\), \(\overline{v'c'}\), \(\overline{w'c'}\) (columns uc, vc, wc; ppm·m/s) — turbulent concentration fluxes
  • \(\overline{u'\theta'}\), \(\overline{v'\theta'}\), \(\overline{w'\theta'}\) (columns uT, vT, wT; K·m/s) — turbulent heat fluxes (\(\theta'\): the temperature fluctuation)
  • \(\theta = \dfrac{T_f - T}{T_f - T_H}\) (dimensionless) — floor-referenced temperature the solves of Cases J and L are scored on: 0 at the floor, 1 in the approach air at \(H\); \(T_f\) is the floor temperature and \(T_H\) the temperature of the approach flow at \(H\)

Scores

  • \(n\) — number of pairs of a measured value \(o_i\) and a modelled value \(p_i\) at one point
  • \(R\) — Pearson correlation coefficient of the pairs
  • \(R^2\) — square of \(R\): share of the measured variance a linear fit to the model explains
  • \(\mathrm{FAC2}\) — fraction of pairs with \(0.5 \le p_i/o_i \le 2\)
  • \(\mathrm{FB}\) — fractional bias \(2(\overline{o}-\overline{p})/(\overline{o}+\overline{p})\), positive when the model is low
  • \(\mathrm{HR}\) (hit rate) — fraction of pairs with \(\lvert p_i-o_i\rvert/\lvert o_i\rvert \le \delta_{\mathrm{rel}}\) or \(\lvert p_i-o_i\rvert \le \delta_{\mathrm{abs}}\), where \(\delta_{\mathrm{rel}} = 0.25\) and \(\delta_{\mathrm{abs}} = 0.05\thinspace U_H\) for a velocity component
  • \(\mathrm{NMSE} = \dfrac{\overline{(o-p)^2}}{\overline{o}\thinspace \overline{p}}\) — normalised mean square error
  • \(\mathrm{NAD} = \dfrac{\overline{\lvert o-p\rvert}}{\overline{o}+\overline{p}}\) — normalised absolute difference
  • \(\mathrm{MG} = \exp\overline{(\ln o-\ln p)}\) — geometric mean bias
  • \(\mathrm{VG} = \exp\overline{(\ln o-\ln p)^2}\) — geometric variance
  • The ratio of \(\mathrm{FAC2}\) keeps its sign, so a model of the other sign than the measurement is a miss; \(\mathrm{FB}\), \(\mathrm{NMSE}\) and \(\mathrm{NAD}\) divide by the means, so they are undefined (shown as —) for a signed component unless the measured and the modelled mean are both positive
  • VDI 3783-9 calls the hit rate \(q\) and the tolerances \(D\) and \(W\); on this site those letters keep their other meanings (\(q\) the tracer release rate, \(D\) the block size of Case C, \(W\) the vertical velocity)
  • The detection limit of a concentration is one value per case, \(10^{-3}\) of the largest measured value. It sets \(\delta_{\mathrm{abs}}\) of the hit rate and the both-below rule of \(\mathrm{FAC2}\), and floors the values in \(\mathrm{MG}\) and \(\mathrm{VG}\).
  • The scores \(\mathrm{FB}\), \(\mathrm{FAC2}\), \(\mathrm{NMSE}\), \(\mathrm{NAD}\), \(\mathrm{MG}\) and \(\mathrm{VG}\) follow Chang & Hanna (2004); the hit rate follows VDI 3783-9.

Quantities scored

  • \(U\), \(V\) and \(W\) (mean velocity components) over \(U_H\)
  • \(k\) (turbulent kinetic energy) over \(U_H^2\)
  • the speed \(\lvert\mathbf{U}\rvert\) and \(\sqrt{\lvert\mathbf{U}\rvert^2+2k}\), against a thermistor’s \(V_{\mathrm{s}}\)
  • \(c^\ast = C/c_0\) (dimensionless concentration) at turbulent Schmidt numbers \(\mathrm{Sc_t}\) of 0.3, 0.5 and 0.7
  • \(\theta\) (floor-referenced temperature)

Measurement locations

Measurement points, Case E
Figure 1. Case E, measurement points: A within 30 m of the 60 m building; B within 30 m of the two 18 m buildings; C elsewhere. Positions in metres, full scale. Dark footprints: the three buildings added in the after state.

Explore the points

model lowmodel high
Loading the points… Hover a point to see where it sits in 3D and how the model differs from the measurement; click to pin it. This needs JavaScript; the figures on this page show the same scores.

OpenFOAM 12

Status: scored

Before and after the construction of a 60 m tower and two 18 m blocks, each state on a 504 m-radius cylinder (about one million cells, 2 m at the buildings), the tunnel’s own profile imposed as a table (wind.inlet: "manual"), the model’s speed over its own solved \(U(15.9\text{ m})\).

Measured against modelled

Case E, measured vs modelled, before, after and the change
Figure 2. Case E, measured vs modelled, before, after and the change. The dots take the colour of their group in Figure 1.
  FAC2 FB hit rate R
before · \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\) 0.95 +0.12 0.61 0.69
before · \(\lvert\mathbf{U}\rvert\) 0.79 +0.27 0.41 0.69
after · \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\) 0.89 +0.23 0.47 0.85
after · \(\lvert\mathbf{U}\rvert\) 0.74 +0.34 0.30 0.84
ceiling control: the tunnel’s before, scored as a model of its after 0.79 +0.37 0.35 0.10
Case E, where the model is slow or fast
Figure 3. Case E, where the model is slow or fast.
  • Construction change (after − before): \(R = 0.84\); the sign is right at 75 % of the points where the tunnel resolved a change; the modelled change is about 60 % of the measured size.
  • Control that ignores the construction (the tunnel’s before as a model of its after): \(R = 0.10\).
  • FB is positive when the model is low.
Interpretation: Case E absolute ratios and the construction change
  • In the change after − before, inflow, closure and instrument biases largely cancel. \(R = 0.84\) is far above the control that ignores the construction.
  • The absolute ratios are low and the cause is not established.
Data notes: Approach-flow sampling

The approach flow reads 0.41 and 0.79 of the imposed table at 1.25 m and 2.5 m. Those readings were taken inside the first cell of the coarse upstream mesh, where the sampling interpolates to zero at the wall (see Inflow).

Scores

Score R \(R^2\) FAC2 FB Hit rate
before, \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\) +0.688 0.474 0.950 +0.124 0.613
before, \(\lvert\mathbf{U}\rvert\) +0.692 0.478 0.787 +0.266 0.412
after, \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\) +0.845 0.714 0.887 +0.226 0.475
after, \(\lvert\mathbf{U}\rvert\) +0.835 0.698 0.738 +0.341 0.300
no-construction ceiling control +0.099 0.010 0.787 +0.368 0.350

Every score is over the same 80 points.

OpenLB

Status: not comparable

Not scored: the case measures only at pedestrian height, 2 m among ~6 m buildings, 1.25 cells above the ground at the \(\mathrm{d}x = 1.6\thinspace\mathrm{m}\) of the Case A and B runs. A point is scored only where every point at its height in an empty-domain control is within 5 % of the imposed log law. In an empty domain 32 m wide and 80 m tall with a log law fitted to Case E’s approach-flow profile below 60 m, on Eddy3D’s openlb-wind:1.9.3-r6 (its ground row half a cell under the domain, so 2 m is 2 m above the wall), 350–650 m from the inlet (where the district’s points sit), \(U\) at 2 m reads 0.39 (0.26–0.58) of the log law with the bounce-back ground, 0.82 (0.70–1.09) with OpenLB’s ground wall model and the rough law, and 0.83 (0.72–1.09) with the power law. The lowest height at which every point is within 5 % is 32 m (20 cells) with the power law and 48 m (30 cells) with the rough law or bounce-back. In a domain 256 m wide, 320 m tall and 1100 m long on 1.9.3-r6, averaged over two crossings of the 2 m layer, \(U\) at 2 m reads 0.90 (0.85–0.94) with the rough law, 0.90 (0.86–0.95) with the power law and 0.41 (0.31–0.51) with bounce-back; with either wall law every point is within 5 % from 6.4 m (4 cells). On the earlier 1.9.3-r4 and -r5, whose bounce-back wall sat half a cell up and whose wall model’s first node a full cell up, the same domain read 1.03 (1.012–1.046) with the rough law over half a crossing and 1.02 (0.985–1.0504) over two.

The engine and the measurements are on the OpenLB and FluidX3D page.

FluidX3D

Status: pending

Not run yet. The case measures only at pedestrian height, 2 m among ~6 m buildings, 1.25 cells above the ground at \(\mathrm{d}x = 1.6\thinspace\mathrm{m}\). A point is scored only where every point at its height in an empty-domain control is within 5 % of the imposed log law. In an empty domain 96 m wide with a log law fitted to Case E’s approach-flow profile below 60 m, at that lattice, 350–650 m from the inlet (where the district’s points sit), \(U\) at 2 m reads 0.99 (0.98–0.99) of the log law with FluidX3D’s ground wall function and a steady inflow, every point within 5 %, and 0.36 (0.20–0.56) with the bounce-back ground. In the 32 m wide domain of the OpenLB control the wall function reads 0.98 (0.92–1.01): beyond about 450 m from the inlet the narrow domain varies across its span. With synthetic inlet turbulence the wide domain reads 1.01 (0.96–1.03). The Niigata district fits on the GPU of the A and B runs at up to about 1.6 cells per 2 m (an estimate from the lattice sizes). The runs of Cases A and B predate the wall function.

The engine and the measurements are on the OpenLB and FluidX3D page.

ML surrogate

Status: scored

Eddy3D’s Wind Predictor (the public Yel-2.0 network) predicts \(\lvert\mathbf{U_{\mathrm{mean}}}\rvert/U_{\mathrm{ref}}\) at one height, 1.8 m, so the case is scaled ×0.9 to put its measurement plane there; the prediction is read at the tunnel’s own sensor coordinates. How the surrogate is run is on the ML surrogate page.

Measured vs predicted, ML surrogate, Case E
Figure 4. Case E, measured vs predicted pedestrian-height speed, ML surrogate, with the 1:1 line and the factor-of-two band.
Quantity n FB FAC2 R hit rate OpenFOAM, same points and quantity
\(V_{\mathrm{s}}/U(15.9\text{ m})\), 16 WD, before + after 2560 +1.00 0.22 +0.43 0.08 —
the same, SW only (both states) 160 +1.07 0.20 +0.53 0.04 \(\lvert\mathbf{U}\rvert\): FB +0.31, FAC2 0.76, R +0.81, hit rate 0.36
  • FB is positive when the model is low. Reversing the wind changes the predicted field by at most \(1 \times 10^{-4}\) \(U_{\mathrm{ref}}\): the prediction does not depend on the wind direction.

Scores

Score R \(R^2\) FAC2 FB Hit rate n
\(V_{\mathrm{s}}/U(15.9\text{ m})\), 16 WD, bc + ac +0.433 0.187 0.225 +0.996 0.082 2560
after construction +0.425 0.181 0.284 +0.853 0.105 1280
after − before +0.399 0.159 0.234 +0.077 0.312 1280
after, lattice cut at ±250 m +0.230 0.053 0.836 +0.053 0.388 1280
wind reversed (control) +0.425 0.181 0.284 +0.853 0.105 1280

Grid uncertainty

OpenFOAM on four meshes (edge ratio \(\sqrt{2}\), 0.45 to 5.1 million cells per state), eddy-viscosity cap lifted as in eddy3d-of12-nutcap-lifted. The served run keeps the cap.

Grid uncertainty, OpenFOAM, Case E
Figure 5. Case E, second mesh of four: measured vs modelled \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\), bar = grid uncertainty. Hollow: no band.
  • Median band: 0.032 before, 0.026 after construction (p90 0.12, 0.10). Most points oscillate between meshes. 46 and 45 of 80 points within the hit rate’s 0.05.
  • Across the meshes: \(\lvert\mathbf{U}\rvert\) FAC2 after construction 0.66–0.78; hit rates move up to 0.10. The construction change keeps \(R\) 0.82–0.84.
  • Point 74 is inside a building on the coarsest mesh: no band.
  • Bands: grid/openfoam12-realizableKE.csv. Method: Grid uncertainty.

Notes on every run

  • Normalisation: velocities by \(U_H\), \(k\) by \(U_H^2\) (the benchmark's own convention; Case E by \(U\) at 15.9 m, as it is published); hit rate \(\delta_{\mathrm{rel}} = 0.25\), \(\delta_{\mathrm{abs}} = 0.05\) in those units

Leaderboard

Rank Run Source Hit rate, \(\sqrt{\lvert\mathbf{U}\rvert^2 + 2k}\) Hit rate, \(\lvert\mathbf{U}\rvert\) Hit rate FAC2 R \(R^2\)
1 OpenFOAM simpleFoam (Eddy3D Outdoor case writer) (eddy3d-of12-nutcap-lifted) community 0.600 0.494 0.547 0.834 +0.785 0.622
2 OpenFOAM simpleFoam (Eddy3D Outdoor case writer) (eddy3d-of12-casee-refined-mesh) community 0.562 0.388 0.475 0.859 +0.789 0.629
3 OpenFOAM 12 · SW Eddy3D 0.544 0.356 0.450 0.841 +0.765 0.591

All runs scored by validation/score_submissions.py. Ranked by mean hit rate (VDI 3783) over the tasks; bold: best per column. Not ranked: the ML surrogate (no point ids) and negative controls. Community rows are self-reported (Validate your own solver).