Case B: reference data
Contents
Configuration
| Parameter | Value |
|---|---|
| Building | 1:4:4 (depth : width : height) slab |
| Depth (m) | 0.05 |
| Width (m) | 0.2 |
| Height H (m) | 0.2 |
| Reynolds number \(\mathrm{Re_H}\) | 72,000 |
| \(U_H\) (m/s) | 5.133 |
| Wind directions (°) | 0 |
| Measurement planes | vertical centre plane \(y/H = 0\), horizontal \(z/H = 1/16\) |
| Instrument | hot-wire anemometer, split-fibre probe, 100 Hz, 60 s per point |
| Wind tunnel | Niigata Institute of Technology, Kashiwazaki |
| Scale, note | model scale; Eddy3D solves it at 1:100 (\(H = 20\thinspace\mathrm{m}\)) with the tunnel velocities |
Nomenclature: symbols, columns and scores
Geometry, reference scales and release
- \(H\), \(b\), \(D\) (m) — height of the building, cube, tower or tree belt; width of the building; edge of the cubes of Case C: the lengths the cases are drawn and normalised by
- \(U_H\) (m/s) — reference speed: the mean approach-flow speed at the height \(H\) (each Data page gives the value used)
- \(U_R\), \(H_R\), \(Z_R\) (m/s, m) — reference speed and height of a workbook: Case E, \(U_R\) at \(Z_R\) = 250 m full scale (1 m in the model); Case M, \(U_R\) and \(H_R\) at the reference point of the tunnel and of each field run
- \(U_{\mathrm{ref}}\), \(L_{\mathrm{ref}}\) (m/s, m) — reference speed and length of a case’s normalisation: \(U_H\) and \(H\) (\(U_R\) and \(H_R\) in Case M); for the velocity ratios the approach speed at 15.9 m (Case E) or at 500 m (Case F)
- \(U_b\) (m/s) — Case G: mean approach-flow speed at 9 m, the normalisation of its approach-flow table
- \(q\), \(c_{\mathrm{gas}}\) (m³/s, ppm) — tracer release of the experiment: volume flow of the released gas, and its tracer content (\(10^6\) ppm when pure); \(Q\) is the source strength given to a solve
- \(R_b\) (dimensionless) — bulk Richardson number of the heated-floor cases J and L (negative: unstable stratification)
- \(\mathrm{Re_H}\), \(\mathrm{Re_D}\) (dimensionless) — Reynolds numbers \(U_H H/\nu\) and \(U_H D/\nu\) (\(\nu\): kinematic viscosity of air)
- \(u_\ast\), \(z_0\), \(\kappa\) (m/s, mm, dimensionless) — friction velocity and roughness length of the log law fitted to the approach flow, and the von Kármán constant (0.41)
- \(\mathrm{WD}\) (column
wind_direction_deg; °) — wind direction (each frame says how it is counted); \(\mathrm{WD_R}\) is the mean direction of a field run at its reference point (Case M) - \(x\), \(y\), \(z\) (columns
x,y,z; m) — coordinates in the case’s frame (\(+x\), \(+y\) and \(+z\) are the positive directions; each Data page says which way \(+x\) points), \(z\) up from the floor of the tunnel or from the ground - \(\mathrm{d}x\) (m) — lattice spacing of the OpenLB and FluidX3D runs, in metres or as a fraction of \(H\) (\(H/64\))
- \(L_r\) (m) — reattachment length behind the building, read from a wake line at ground level; reported as \(L_r/H\)
Velocity and turbulence
- \(U\), \(V\), \(W\) (columns
U,V,W; m/s) — mean velocity along \(+x\), \(+y\), \(+z\); \(V\) is positive toward \(+y\) in every case - \(\lvert\mathbf{U}\rvert\) (m/s) — magnitude of the mean velocity vector, \(\sqrt{U^2+V^2+W^2}\)
- \(V_{\mathrm{s}}\) (column
Vs; m/s) — mean omnidirectional scalar speed of a thermistor (never a vector magnitude) - \(\overline{u'u'}\), \(\overline{v'v'}\), \(\overline{w'w'}\) (columns
uu,vv,ww; m²/s²) — velocity variances (overbar: time average, prime: fluctuation about it) - \(\overline{u'v'}\), \(\overline{u'w'}\), \(\overline{v'w'}\) (columns
uv,uw,vw; m²/s²) — Reynolds shear stresses - \(k = \tfrac{1}{2}\left(\overline{u'u'}+\overline{v'v'}+\overline{w'w'}\right)\) (column
k; m²/s²) — turbulent kinetic energy - \(U/U_{\mathrm{ref}}\) (column
velocity_ratio; dimensionless) — mean speed over the case’s reference speed (\(V_{\mathrm{s}}/U_{\mathrm{ref}}\) for a thermistor) - \(\sigma_{U/U_{\mathrm{ref}}}\) (column
velocity_ratio_sd; dimensionless) — standard deviation ofvelocity_ratioover the observations behind a field value (Case F) - \(k/U_{\mathrm{ref}}^2\) (column
k_ratio; dimensionless) — turbulent kinetic energy over the square of the reference speed, where only normalised values are published (Case G)
Concentration and temperature
- \(C\) (column
C; ppm) — mean tracer-gas concentration as published (volume fraction \(\times 10^6\) of the released gas diluted in air) - \(c_{\mathrm{rms}}\) (column
c_rms; ppm) — root mean square of the concentration fluctuation - \(c_0\) (ppm) — reference concentration, defined for each case on its Data page: \(c_0 = \dfrac{c_{\mathrm{gas}}\thinspace q}{U_H H^2}\) (\(U_R H_R^2\) in the denominator in Case M)
- \(c^\ast\) (column
concentration_ratio; dimensionless) — dimensionless concentration \(c^\ast = C/c_0\); the value of a solve is \(c\thinspace U_H H^2/Q\) for its mean concentration \(c\) and its source strength \(Q\) - \(\mathrm{Sc_t}\) (dimensionless) — turbulent Schmidt number of a solve (0.3, 0.5 and 0.7)
- \(T\), \(T_{\mathrm{rms}}\) (columns
T,T_rms; °C, K) — mean air temperature as published (Cases J and L) and the root mean square of its fluctuation - \(\overline{u'c'}\), \(\overline{v'c'}\), \(\overline{w'c'}\) (columns
uc,vc,wc; ppm·m/s) — turbulent concentration fluxes - \(\overline{u'\theta'}\), \(\overline{v'\theta'}\), \(\overline{w'\theta'}\) (columns
uT,vT,wT; K·m/s) — turbulent heat fluxes (\(\theta'\): the temperature fluctuation) - \(\theta = \dfrac{T_f - T}{T_f - T_H}\) (dimensionless) — floor-referenced temperature the solves of Cases J and L are scored on: 0 at the floor, 1 in the approach air at \(H\); \(T_f\) is the floor temperature and \(T_H\) the temperature of the approach flow at \(H\)
Scores
- \(n\) — number of pairs of a measured value \(o_i\) and a modelled value \(p_i\) at one point
- \(R\) — Pearson correlation coefficient of the pairs
- \(R^2\) — square of \(R\): share of the measured variance a linear fit to the model explains
- \(\mathrm{FAC2}\) — fraction of pairs with \(0.5 \le p_i/o_i \le 2\)
- \(\mathrm{FB}\) — fractional bias \(2(\overline{o}-\overline{p})/(\overline{o}+\overline{p})\), positive when the model is low
- \(\mathrm{HR}\) (hit rate) — fraction of pairs with \(\lvert p_i-o_i\rvert/\lvert o_i\rvert \le \delta_{\mathrm{rel}}\) or \(\lvert p_i-o_i\rvert \le \delta_{\mathrm{abs}}\), where \(\delta_{\mathrm{rel}} = 0.25\) and \(\delta_{\mathrm{abs}} = 0.05\thinspace U_H\) for a velocity component
- \(\mathrm{NMSE} = \dfrac{\overline{(o-p)^2}}{\overline{o}\thinspace \overline{p}}\) — normalised mean square error
- \(\mathrm{NAD} = \dfrac{\overline{\lvert o-p\rvert}}{\overline{o}+\overline{p}}\) — normalised absolute difference
- \(\mathrm{MG} = \exp\overline{(\ln o-\ln p)}\) — geometric mean bias
- \(\mathrm{VG} = \exp\overline{(\ln o-\ln p)^2}\) — geometric variance
- The ratio of \(\mathrm{FAC2}\) keeps its sign, so a model of the other sign than the measurement is a miss; \(\mathrm{FB}\), \(\mathrm{NMSE}\) and \(\mathrm{NAD}\) divide by the means, so they are undefined (shown as —) for a signed component unless the measured and the modelled mean are both positive
- VDI 3783-9 calls the hit rate \(q\) and the tolerances \(D\) and \(W\); on this site those letters keep their other meanings (\(q\) the tracer release rate, \(D\) the block size of Case C, \(W\) the vertical velocity)
- The detection limit of a concentration is one value per case, \(10^{-3}\) of the largest measured value. It sets \(\delta_{\mathrm{abs}}\) of the hit rate and the both-below rule of \(\mathrm{FAC2}\), and floors the values in \(\mathrm{MG}\) and \(\mathrm{VG}\).
- The scores \(\mathrm{FB}\), \(\mathrm{FAC2}\), \(\mathrm{NMSE}\), \(\mathrm{NAD}\), \(\mathrm{MG}\) and \(\mathrm{VG}\) follow Chang & Hanna (2004); the hit rate follows VDI 3783-9.
Quantities scored
- \(U\), \(V\) and \(W\) (mean velocity components) over \(U_H\)
- \(k\) (turbulent kinetic energy) over \(U_H^2\)
- the speed \(\lvert\mathbf{U}\rvert\) and \(\sqrt{\lvert\mathbf{U}\rvert^2+2k}\), against a thermistor’s \(V_{\mathrm{s}}\)
- \(c^\ast = C/c_0\) (dimensionless concentration) at turbulent Schmidt numbers \(\mathrm{Sc_t}\) of 0.3, 0.5 and 0.7
- \(\theta\) (floor-referenced temperature)
Frame and units
| Property | Definition |
|---|---|
| Origin | building centre on the ground plane |
| x | \(+x\) streamwise (the wind at \(\mathrm{WD} = 0\) blows toward \(+x\)); slab spans \(x \in \lbrack -0.025,\thinspace 0.025\rbrack\) |
| y | \(+y\) lateral; slab spans \(y \in \lbrack -0.10,\thinspace 0.10\rbrack\); points published on the y <= 0 half by the tunnel's symmetry convention |
| z | \(+z\) up from the ground; roof at \(z = 0.20\) |
| Lateral sign applied | -1 |
| Coordinate scale applied | 0.001 |
| Unit of length | m (model scale; converted from the published millimetres) |
| Unit of velocity | m/s |
| Unit of variance | m²/s² |
| Unit of \(k\) | m²/s² |
Reference data
Source in this repository: raw/cases/case-b/RS_caseB.csv (approach flow: raw/cases/case-b/AF_caseB.csv).
The cleaned table has 224 rows over 224 distinct points; columns point_id, config, instrument, wind_direction_deg, x, y, z, U, V, W, uu, vv, ww, k, campaign.
| Configuration | Points |
|---|---|
| default, WD 0° | 224 |
Columns
The columns of the cleaned table (points.csv, points.json), in order.
The 15 columns and what each holds
| Column | Symbol | Meaning |
|---|---|---|
point_id | the tunnel's own measurement point number | |
config | configuration key: 'default', Case C centre building '0D'/'1D'/'2D', Case E state 'bc' (before) / 'ac' (after construction) | |
instrument | 'split_fibre' (vector components) or 'thermistor' (omnidirectional scalar speed) | |
wind_direction_deg | AIJ wind direction in degrees; 0 is the case's reference direction (see frame) | |
x | m, case frame | |
y | m, case frame | |
z | m above ground, case frame | |
U | \(U\) | m/s, mean velocity along \(+x\) |
V | \(V\) | m/s, mean velocity along \(+y\) (sign unified: positive toward \(+y\)) |
W | \(W\) | m/s, mean velocity along \(+z\) |
uu | \(\overline{u'u'}\) | m²/s², variance of u |
vv | \(\overline{v'v'}\) | m²/s², variance of v |
ww | \(\overline{w'w'}\) | m²/s², variance of w |
k | \(k\) | m²/s², turbulent kinetic energy |
campaign | 'wind_tunnel' (model scale) or 'field' (a full-scale observation: Cases F, G, M) |
Inflow
| Property | Value |
|---|---|
| Method | log law, \(\kappa\) = 0.41, least squares over \(z = 0.02\thinspace\ldots\thinspace 2H\) on the case's own approach-flow file |
| Friction velocity \(u_\ast\) (m/s) | 0.399 |
| Roughness length \(z_0\) (mm) | 0.882 |
| \(U_H\), measured (m/s) | 5.133 |
| Log-law error at H | +2.9 % |
Known data issues
- The published coordinates are MILLIMETRES (x[mm]) while velocities are m/s. The API serves metres (coordinate_scale_applied = 0.001). Read as metres, every probe lands 1000x too far out.
- The published lateral velocity \(V\) is positive toward -y (\(V\) = +3.630 m/s at (-0.025, -0.110, 0.013), just outside the \(y \lt 0\) side face where the flow must deflect toward -y). The API multiplies \(V\) by -1 (lateral_sign_applied = -1) so that \(V\) is positive toward \(+y\) as in Case A. Scored without this, Case B's \(V\) comes out at \(R = -0.910\) against \(R = +0.959\) for \(U\) on the same points.
- The RANS solution is symmetric, so model \(V\) = 0 on the centre plane while the tunnel measures small non-zero values there.
API
| Resource | Endpoint |
|---|---|
| Case | /api/cases/B.json |
| Points (JSON) | /api/cases/B/points.json |
| Points (CSV) | /api/cases/B/points.csv |
| Approach flow (CSV) | /api/cases/B/approach_flow.csv |
| Geometry | /api/cases/B/geometry.json |
| Geometry (STL) | /api/cases/B/geometry.stl |
| Validation | /api/cases/B/validation.json |
Attribution
- Data collected by Yoshihide Tominaga (Niigata Institute of Technology).
- Edited and distributed by Hideki Kikumoto (The University of Tokyo) and Tsubasa Okaze (Institute of Science Tokyo).
- DOI: 10.5281/zenodo.15401455
- Citation requested: Miyazaki, T., Tominaga, Y. (2003). Wind tunnel experiment on flow field around a building model with a scale ratio of 4:4:1 placed within the surface boundary layer. Proc. Annual Meeting of Hokuriku Chapter, AIJ, 201-204 (in Japanese). https://www.aij.or.jp/paper/detail.html?productId=313933
- Licence: CC BY 4.0
Cite
APA
Tominaga, Y., Kikumoto, H., & Okaze, T. (2025). AIJ UWE Benchmark Dataset – Case B (144): Wind Tunnel Experiment for Flow around a 1:4:4 Shape Building Model [Data set]. Zenodo. https://doi.org/10.5281/zenodo.15401455
BibTeX
@misc{aijuwe_case_b,
author = "Tominaga, Yoshihide and Kikumoto, Hideki and Okaze, Tsubasa",
title = "{AIJ UWE Benchmark Dataset -- Case B (144): Wind Tunnel Experiment for Flow around a 1:4:4 Shape Building Model}",
year = "2025",
publisher = "Zenodo",
doi = "10.5281/zenodo.15401455",
url = "https://doi.org/10.5281/zenodo.15401455",
note = "Data set"
}
API: see About.