Case L: validation
Contents
Engine status: OpenFOAM 12 (UMF) scored · OpenLB pending · FluidX3D pending · ML surrogate pending
Nomenclature: symbols, columns and scores
Geometry, reference scales and release
- \(H\), \(b\), \(D\) (m) — height of the building, cube, tower or tree belt; width of the building; edge of the cubes of Case C: the lengths the cases are drawn and normalised by
- \(U_H\) (m/s) — reference speed: the mean approach-flow speed at the height \(H\) (each Data page gives the value used)
- \(U_R\), \(H_R\), \(Z_R\) (m/s, m) — reference speed and height of a workbook: Case E, \(U_R\) at \(Z_R\) = 250 m full scale (1 m in the model); Case M, \(U_R\) and \(H_R\) at the reference point of the tunnel and of each field run
- \(U_{\mathrm{ref}}\), \(L_{\mathrm{ref}}\) (m/s, m) — reference speed and length of a case’s normalisation: \(U_H\) and \(H\) (\(U_R\) and \(H_R\) in Case M); for the velocity ratios the approach speed at 15.9 m (Case E) or at 500 m (Case F)
- \(U_b\) (m/s) — Case G: mean approach-flow speed at 9 m, the normalisation of its approach-flow table
- \(q\), \(c_{\mathrm{gas}}\) (m³/s, ppm) — tracer release of the experiment: volume flow of the released gas, and its tracer content (\(10^6\) ppm when pure); \(Q\) is the source strength given to a solve
- \(R_b\) (dimensionless) — bulk Richardson number of the heated-floor cases J and L (negative: unstable stratification)
- \(\mathrm{Re_H}\), \(\mathrm{Re_D}\) (dimensionless) — Reynolds numbers \(U_H H/\nu\) and \(U_H D/\nu\) (\(\nu\): kinematic viscosity of air)
- \(u_\ast\), \(z_0\), \(\kappa\) (m/s, mm, dimensionless) — friction velocity and roughness length of the log law fitted to the approach flow, and the von Kármán constant (0.41)
- \(\mathrm{WD}\) (column
wind_direction_deg; °) — wind direction (each frame says how it is counted); \(\mathrm{WD_R}\) is the mean direction of a field run at its reference point (Case M) - \(x\), \(y\), \(z\) (columns
x,y,z; m) — coordinates in the case’s frame (\(+x\), \(+y\) and \(+z\) are the positive directions; each Data page says which way \(+x\) points), \(z\) up from the floor of the tunnel or from the ground - \(\mathrm{d}x\) (m) — lattice spacing of the OpenLB and FluidX3D runs, in metres or as a fraction of \(H\) (\(H/64\))
- \(L_r\) (m) — reattachment length behind the building, read from a wake line at ground level; reported as \(L_r/H\)
Velocity and turbulence
- \(U\), \(V\), \(W\) (columns
U,V,W; m/s) — mean velocity along \(+x\), \(+y\), \(+z\); \(V\) is positive toward \(+y\) in every case - \(\lvert\mathbf{U}\rvert\) (m/s) — magnitude of the mean velocity vector, \(\sqrt{U^2+V^2+W^2}\)
- \(V_{\mathrm{s}}\) (column
Vs; m/s) — mean omnidirectional scalar speed of a thermistor (never a vector magnitude) - \(\overline{u'u'}\), \(\overline{v'v'}\), \(\overline{w'w'}\) (columns
uu,vv,ww; m²/s²) — velocity variances (overbar: time average, prime: fluctuation about it) - \(\overline{u'v'}\), \(\overline{u'w'}\), \(\overline{v'w'}\) (columns
uv,uw,vw; m²/s²) — Reynolds shear stresses - \(k = \tfrac{1}{2}\left(\overline{u'u'}+\overline{v'v'}+\overline{w'w'}\right)\) (column
k; m²/s²) — turbulent kinetic energy - \(U/U_{\mathrm{ref}}\) (column
velocity_ratio; dimensionless) — mean speed over the case’s reference speed (\(V_{\mathrm{s}}/U_{\mathrm{ref}}\) for a thermistor) - \(\sigma_{U/U_{\mathrm{ref}}}\) (column
velocity_ratio_sd; dimensionless) — standard deviation ofvelocity_ratioover the observations behind a field value (Case F) - \(k/U_{\mathrm{ref}}^2\) (column
k_ratio; dimensionless) — turbulent kinetic energy over the square of the reference speed, where only normalised values are published (Case G)
Concentration and temperature
- \(C\) (column
C; ppm) — mean tracer-gas concentration as published (volume fraction \(\times 10^6\) of the released gas diluted in air) - \(c_{\mathrm{rms}}\) (column
c_rms; ppm) — root mean square of the concentration fluctuation - \(c_0\) (ppm) — reference concentration, defined for each case on its Data page: \(c_0 = \dfrac{c_{\mathrm{gas}}\thinspace q}{U_H H^2}\) (\(U_R H_R^2\) in the denominator in Case M)
- \(c^\ast\) (column
concentration_ratio; dimensionless) — dimensionless concentration \(c^\ast = C/c_0\); the value of a solve is \(c\thinspace U_H H^2/Q\) for its mean concentration \(c\) and its source strength \(Q\) - \(\mathrm{Sc_t}\) (dimensionless) — turbulent Schmidt number of a solve (0.3, 0.5 and 0.7)
- \(T\), \(T_{\mathrm{rms}}\) (columns
T,T_rms; °C, K) — mean air temperature as published (Cases J and L) and the root mean square of its fluctuation - \(\overline{u'c'}\), \(\overline{v'c'}\), \(\overline{w'c'}\) (columns
uc,vc,wc; ppm·m/s) — turbulent concentration fluxes - \(\overline{u'\theta'}\), \(\overline{v'\theta'}\), \(\overline{w'\theta'}\) (columns
uT,vT,wT; K·m/s) — turbulent heat fluxes (\(\theta'\): the temperature fluctuation) - \(\theta = \dfrac{T_f - T}{T_f - T_H}\) (dimensionless) — floor-referenced temperature the solves of Cases J and L are scored on: 0 at the floor, 1 in the approach air at \(H\); \(T_f\) is the floor temperature and \(T_H\) the temperature of the approach flow at \(H\)
Scores
- \(n\) — number of pairs of a measured value \(o_i\) and a modelled value \(p_i\) at one point
- \(R\) — Pearson correlation coefficient of the pairs
- \(R^2\) — square of \(R\): share of the measured variance a linear fit to the model explains
- \(\mathrm{FAC2}\) — fraction of pairs with \(0.5 \le p_i/o_i \le 2\)
- \(\mathrm{FB}\) — fractional bias \(2(\overline{o}-\overline{p})/(\overline{o}+\overline{p})\), positive when the model is low
- \(\mathrm{HR}\) (hit rate) — fraction of pairs with \(\lvert p_i-o_i\rvert/\lvert o_i\rvert \le \delta_{\mathrm{rel}}\) or \(\lvert p_i-o_i\rvert \le \delta_{\mathrm{abs}}\), where \(\delta_{\mathrm{rel}} = 0.25\) and \(\delta_{\mathrm{abs}} = 0.05\thinspace U_H\) for a velocity component
- \(\mathrm{NMSE} = \dfrac{\overline{(o-p)^2}}{\overline{o}\thinspace \overline{p}}\) — normalised mean square error
- \(\mathrm{NAD} = \dfrac{\overline{\lvert o-p\rvert}}{\overline{o}+\overline{p}}\) — normalised absolute difference
- \(\mathrm{MG} = \exp\overline{(\ln o-\ln p)}\) — geometric mean bias
- \(\mathrm{VG} = \exp\overline{(\ln o-\ln p)^2}\) — geometric variance
- The ratio of \(\mathrm{FAC2}\) keeps its sign, so a model of the other sign than the measurement is a miss; \(\mathrm{FB}\), \(\mathrm{NMSE}\) and \(\mathrm{NAD}\) divide by the means, so they are undefined (shown as —) for a signed component unless the measured and the modelled mean are both positive
- VDI 3783-9 calls the hit rate \(q\) and the tolerances \(D\) and \(W\); on this site those letters keep their other meanings (\(q\) the tracer release rate, \(D\) the block size of Case C, \(W\) the vertical velocity)
- The detection limit of a concentration is one value per case, \(10^{-3}\) of the largest measured value. It sets \(\delta_{\mathrm{abs}}\) of the hit rate and the both-below rule of \(\mathrm{FAC2}\), and floors the values in \(\mathrm{MG}\) and \(\mathrm{VG}\).
- The scores \(\mathrm{FB}\), \(\mathrm{FAC2}\), \(\mathrm{NMSE}\), \(\mathrm{NAD}\), \(\mathrm{MG}\) and \(\mathrm{VG}\) follow Chang & Hanna (2004); the hit rate follows VDI 3783-9.
Quantities scored
- \(U\), \(V\) and \(W\) (mean velocity components) over \(U_H\)
- \(k\) (turbulent kinetic energy) over \(U_H^2\)
- the speed \(\lvert\mathbf{U}\rvert\) and \(\sqrt{\lvert\mathbf{U}\rvert^2+2k}\), against a thermistor’s \(V_{\mathrm{s}}\)
- \(c^\ast = C/c_0\) (dimensionless concentration) at turbulent Schmidt numbers \(\mathrm{Sc_t}\) of 0.3, 0.5 and 0.7
- \(\theta\) (floor-referenced temperature)
Measurement locations
Explore the points
OpenFOAM 12
Status: scored
Case L is non-isothermal: a floor held at 45.0 °C under a cooler approach flow (bulk Richardson number −0.034), with an ethylene tracer released from the floor. Eddy3D solved it with its buoyant microclimate engine, urbanMicroclimateFoam (UMF, the Outdoor+ plugin), an OpenFOAM 12 solver developed at ETH Zurich and Empa (its engine ids are on the Validation overview; Eddy3D owns none of its physics). The isothermal OpenFOAM 12 solver was not run on this case.
- What the run is. Solved on 2026-10-18. 126 cubes (14 rows × 9 columns), 754,940 air cells, realizable k-ε. The air region stopped at its 1500-iteration cap with the residual control unmet; at the last iteration the initial residuals of \(U_y\) and
p_rghwere of the order of \(10^{-2}\) and those of the tracers \(10^{-3}\). Solved on one mesh, with a steady tracer solved beside the flow as three species (turbulent Schmidt numbers 0.3, 0.5 and 0.7, all published). - Froude scale. The production case writer cannot mesh the tunnel model, so the scene is the tunnel scaled by 100: lengths times the scale, velocities times its square root, temperatures unchanged. The Richardson number, Pr and the Kelvin values are kept; the Reynolds number is not. Every pair is in the tunnel’s units: coordinates divided by the scale, velocities by the scene’s \(U_H\), \(k\) by its square.
- Temperature is scored as the floor-referenced fraction \(\theta = (T_f - T)/(T_f - T_H)\), 0 at the floor and 1 in the approach air at the building height (the workbook’s own normalisation). \(\theta\) lies between 0.4 and 1.1. The temperature errors in kelvin are in the files (
temperature.all). - Concentration is the measured \(C/c_0\) (\(c_0\) = 1728 ppm) against the model’s ethylene mass fraction as ppm over the same \(c_0\), with one detection limit of \(10^{-3}\) of the largest measured value.
- Tracer mass balance. The outlet carried 0.86, 0.73 and 0.70 (for \(\mathrm{Sc_t}\) 0.3, 0.5 and 0.7) of the emission.
- FB is positive when the model is low, and is left out (—) for a signed component whose measured and modelled means are not both positive.
Interpretation: Engine, scale and temperature scoring
- The isothermal OpenFOAM 12 solver Eddy3D uses for the other cases cannot represent a heated floor, which is why this case was solved with UMF.
- Temperature FAC2 is 1.00 almost everywhere because \(\theta\) lies between 0.4 and 1.1, so R and the hit rate carry the comparison.
- The Froude scale keeps the Richardson number, Pr and the Kelvin values and changes the Reynolds number, so the wall-function regime of the model differs from the tunnel’s.
Measured against modelled
| Quantity | R | FAC2 | FB | Hit rate | n |
|---|---|---|---|---|---|
| \(U\) | +0.918 | 0.608 | +0.268 | 0.506 | 344 |
| \(V\) | −0.037 | 0.291 | −0.795 | 0.747 | 344 |
| \(W\) | −0.027 | 0.183 | — | 0.762 | 344 |
| \(\lvert\mathbf{U}\rvert\) | +0.898 | 0.674 | +0.206 | 0.515 | 344 |
| \(k\) | +0.145 | 0.584 | +0.635 | 0.244 | 344 |
| \(\theta\) | +0.936 | 1.000 | +0.049 | 0.985 | 344 |
| \(c^\ast\), \(\mathrm{Sc_t}\) 0.3 | +0.798 | 0.759 | −0.498 | 0.468 | 344 |
| \(c^\ast\), \(\mathrm{Sc_t}\) 0.5 | +0.766 | 0.683 | −0.649 | 0.387 | 344 |
| \(c^\ast\), \(\mathrm{Sc_t}\) 0.7 | +0.746 | 0.602 | −0.731 | 0.358 | 344 |
| \(U\), points at or above 30 mm | +0.902 | 0.798 | +0.147 | 0.669 | 242 |
| \(k\), points at or above 30 mm | +0.468 | 0.802 | +0.364 | 0.343 | 242 |
| \(\theta\), points at or above 30 mm | +0.944 | 1.000 | +0.041 | 1.000 | 242 |
| \(c^\ast\), \(\mathrm{Sc_t}\) 0.3, points at or above 30 mm | +0.814 | 0.715 | −0.495 | 0.430 | 242 |
| \(c^\ast\), \(\mathrm{Sc_t}\) 0.5, points at or above 30 mm | +0.821 | 0.636 | −0.583 | 0.351 | 242 |
| \(c^\ast\), \(\mathrm{Sc_t}\) 0.7, points at or above 30 mm | +0.816 | 0.541 | −0.624 | 0.302 | 242 |
| \(V\), lateral sign flipped (control) | +0.037 | 0.110 | — | 0.695 | 344 |
| \(U\), approach column alone (control) | +0.861 | 0.846 | −0.205 | 0.599 | 344 |
| \(\theta\), approach column alone (control) | +0.925 | 1.000 | −0.117 | 0.837 | 344 |
| \(U\), y-symmetric ceiling (control) | +0.984 | 0.986 | +0.000 | 0.860 | 292 |
The 51 points at \(z = 4\thinspace\mathrm{mm}\) lie inside the model’s first fine cell (0.75 m, 0.4 m at 1:100), a wall-function cell; the 242 points at or above 30 mm are scored separately.
- Flow. \(U\): \(R = 0.92\), and the mean \(U/U_H\) is 0.499 modelled against 0.654 measured; at or above 30 mm R is 0.90 and FAC2 0.80. Against the undisturbed approach column, the model’s R is higher (\(U\): 0.918 against 0.861; \(\theta\): 0.936 against 0.925). The model’s mean \(U/U_H\) in the streets is 0.045 below 30 mm and 1.11 above 110 mm, against the tunnel’s 0.297 and 1.068. \(V\) and \(W\): R is −0.04 and −0.03, and with the sign of \(V\) flipped it is +0.04.
- \(k\). \(R = 0.15\) (0.47 at or above 30 mm), FB +0.64.
- Temperature. \(\theta\): \(R = 0.94\), hit rate 0.99. The mean bias is +1.17 K, the mean absolute error 1.59 K and the root-mean-square error 2.11 K.
- Tracer. R is 0.80, 0.77 and 0.75 from \(\mathrm{Sc_t}\) 0.3 to 0.7 (0.81 to 0.82 at or above 30 mm); FAC2 falls from 0.76 to 0.60 and FB from −0.50 to −0.73. The largest modelled \(c^\ast\) is 3.3, 4.0 and 5.0 (at \(y = -0.12,\thinspace +0.18\text{ and }+0.18\thinspace\mathrm{m}\), in the source street) against the tunnel’s 1.93 at (−0.15, −0.12, 0.004).
Interpretation: Case L flow, temperature and tracer
- The streamwise flow and the temperature follow the tunnel; the streets do not. The model beats the undisturbed approach column on R, which is the number a model of the array has to beat. The street air is nearly stagnant in the model. \(V\) and \(W\) carry no pattern.
- \(k\) is low and weakly correlated.
- The model is warmer by 1.2 K on average.
- The tracer is over-predicted and the pattern is correlated.
Vertical profiles
Where along the height the model meets the measurement, station by station.
Field maps
The solved velocity on the measured planes, every point drawn on it as a dot coloured by its measured value on the same scale: a dot that stands out from the colour around it is a point the model misses.
Scores
Quantity: \(U\), \(V\), \(W\), the speed \(\lvert\mathbf{U}\rvert\) over \(U_H\) = 1.3394 m/s and \(k\) over \(U_H^2\) (the tunnel's units, 344 points); theta = (\(T_f - T\))/(\(T_f - T_H\)) with \(T_f\) = 45.01 degC and \(T_f - T_H\) = 30.26 K; \(c^\ast = C/c_0\) (\(c_0\) = 1728 ppm) against the model's ethylene mass fraction as ppm over the same \(c_0\), for turbulent Schmidt numbers 0.3, 0.5 and 0.7; also the 242 points at or above 30 mm, the first four fine cells above the floor. The scene is the tunnel at Froude scale 100.
All 19 headline scores
| Score | R | \(R^2\) | FAC2 | FB | Hit rate | n |
|---|---|---|---|---|---|---|
| \(U\) | +0.918 | 0.843 | 0.608 | +0.268 | 0.506 | 344 |
| \(V\) | -0.037 | 0.001 | 0.291 | -0.795 | 0.747 | 344 |
| \(W\) | -0.027 | 0.001 | 0.183 | — | 0.762 | 344 |
| \(\lvert\mathbf{U}\rvert\) | +0.898 | 0.807 | 0.674 | +0.206 | 0.515 | 344 |
| \(k\) | +0.145 | 0.021 | 0.584 | +0.635 | 0.244 | 344 |
| \(\theta\), floor-referenced temperature | +0.936 | 0.876 | 1.000 | +0.049 | 0.985 | 344 |
| \(c^\ast\), \(\mathrm{Sc_t}\) 0.3 | +0.798 | 0.637 | 0.759 | -0.498 | 0.468 | 344 |
| \(c^\ast\), \(\mathrm{Sc_t}\) 0.5 | +0.766 | 0.587 | 0.683 | -0.649 | 0.387 | 344 |
| \(c^\ast\), \(\mathrm{Sc_t}\) 0.7 | +0.746 | 0.556 | 0.602 | -0.731 | 0.358 | 344 |
| \(U\), points at or above 30 mm | +0.902 | 0.814 | 0.798 | +0.147 | 0.669 | 242 |
| \(k\), points at or above 30 mm | +0.468 | 0.219 | 0.802 | +0.364 | 0.343 | 242 |
| \(\theta\), points at or above 30 mm | +0.944 | 0.892 | 1.000 | +0.041 | 1.000 | 242 |
| \(c^\ast\), \(\mathrm{Sc_t}\) 0.3, points at or above 30 mm | +0.814 | 0.663 | 0.715 | -0.495 | 0.430 | 242 |
| \(c^\ast\), \(\mathrm{Sc_t}\) 0.5, points at or above 30 mm | +0.821 | 0.675 | 0.636 | -0.583 | 0.351 | 242 |
| \(c^\ast\), \(\mathrm{Sc_t}\) 0.7, points at or above 30 mm | +0.816 | 0.667 | 0.541 | -0.624 | 0.302 | 242 |
| \(V\), lateral sign flipped (control) | +0.037 | 0.001 | 0.110 | — | 0.695 | 344 |
| \(U\), approach column alone (control) | +0.861 | 0.741 | 0.846 | -0.205 | 0.599 | 344 |
| \(\theta\), approach column alone (control) | +0.925 | 0.856 | 1.000 | -0.117 | 0.837 | 344 |
| \(U\), y-symmetric ceiling (control) | +0.984 | 0.968 | 0.986 | +0.000 | 0.860 | 292 |
- Normalisation: the tunnel's units: velocities by \(U_H\) (1.3394 m/s measured, the Froude-scaled 13.39 m/s modelled), \(k\) by \(U_H^2\), temperature as theta = (\(T_f - T\))/(\(T_f - T_H\)) (\(T_f\) = 45.01 degC, \(T_f - T_H\) = 30.26 K), \(c^\ast = C/c_0\) (\(c_0\) = 1728 ppm) against the modelled ethylene mass fraction as ppm over the same \(c_0\); hit rate \(\delta_{\mathrm{rel}} = 0.25\), \(\delta_{\mathrm{abs}} = 0.05\) in those units, concentration with one detection limit of \(10^{-3}\) of the largest measured value
- Per-point values:
/api/cases/L/pairs/umf-realizableKE.csv - Reproduce: Eddy3D fixture MetaFOAM.Lib.Tests/TestAijCaseLUmfContainerE2E (9 x 14 cubes, heated floor, floor line source; urbanMicroclimateFoam, realizable k-ε, 754,940 air cells at Froude scale 100, 1500 air iterations, solved 2026-10-18); figures validation/plot_cases_jl_umf.py
Notes:
- The scene is the tunnel at Froude scale 100 (lengths times 100, velocities times 10, temperatures unchanged), which keeps the bulk Richardson number (-0.034) and the tunnel's Kelvin values and does not keep Re.
- What the model does not represent: the gas's own heat and the buried slot (a mass rate into 624 whole cells, a strip 3 m wide), the tunnel's near-floor temperature drop (below the first cell), the measured velocity profile (UMF's inlet is a log law), the tunnel's no-slip side walls and ceiling (slip here), radiation (emissivity 0.01, effectively off) and the 10 mm raised block floor.
- 51 of the 344 points (\(z = 4\thinspace\mathrm{mm}\), 0.4 m here) lie inside the first fine cell (0.75 m), a wall-function cell. The 242 points at or above 30 mm are scored separately.
- The street air is nearly stagnant in the model: the mean \(U/U_H\) in the streets is 0.045 below 30 mm and 1.11 above 110 mm, against the tunnel's 0.297 and 1.068; the model's approach column differs from the tunnel's AF profile by up to 39 % above 30 mm (UMF's inlet is a log law, the tunnel's profile is not).
- The tracer is solved steady beside the flow, as three species of one flow. The outlet carried 0.86, 0.73 and 0.70 of the emission for \(\mathrm{Sc_t}\) 0.3, 0.5 and 0.7, within the factor of two accepted as a check on the wiring. The largest modelled \(c^\ast\) over the 344 points is in the source street for every species, at \(y = -0.12\thinspace\mathrm{m}\) (\(\mathrm{Sc_t}\) 0.3) and \(y = +0.18\thinspace\mathrm{m}\) (\(\mathrm{Sc_t}\) 0.5 and 0.7), against the tunnel's 1.929 at (-0.15, -0.12, 0.004).
- The air region ended at its 1500-iteration cap with the residualControl unmet (no 'solution converged' line); at the last iteration the initial residuals were 2.6e-2 (\(U_y\)), 3.0e-2 (
p_rgh) and 1.1e-3 to 2.0e-3 (the tracers). - The tunnel is not y-symmetric although the array is: over 110 mirror pairs the mean |U(y) - \(U\)(-y)| is 0.143 \(U_H\) in the tunnel and 0.058 \(U_H\) in the model. \(V\) is barely antisymmetric in the tunnel, so it cannot be scored as a pattern; the sign-flipped control shows what a wrong sign scores.
- The inlet's \(U_H\) reaches the array within 20 %; the approach air is warmest at the floor; the street air near the floor is warmer than the approach air at H and cools with height; the street flow is slower than the flow above the array; every species emits and its largest value is in the source street.
Not run
- A second mesh, a longer iteration count and a transient run.
- OpenLB, FluidX3D and the ML surrogate.
- Not represented in the model (Eddy3D’s list): the release momentum and the gas’s own heat; the tunnel’s side walls and ceiling (slip here); radiation (emissivity 0.01, effectively off); the 10 mm raised block floor and the measured velocity profile (UMF’s inlet is a log law; the model’s approach column differs from the tunnel’s by up to 39 % above 30 mm).
Interpretation: Limits of these runs
- The air region reached its cap with residuals near \(10^{-2}\), so these numbers are those of an unconverged steady solve on one mesh.
- The tracer balance closes within a factor of two; why part of the emission is missing at the outlet was not investigated.
How the scores are computed
- Scores recomputed from the pairs by validation/dispersion_metrics.py; the SHA-256 of every file the snapshot was read from is in its results file, under
sources.
Leaderboard
| Rank | Run | Source | Hit rate, \(U\) | Hit rate, \(V\) | Hit rate, \(W\) | Hit rate, \(\lvert\mathbf{U}\rvert\) | Hit rate, \(k\) | Hit rate, \(c^\ast\) | Hit rate, \(\theta\) | Hit rate | FAC2 | R | \(R^2\) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | OpenFOAM simpleFoam (Eddy3D Outdoor case writer) (eddy3d-of12-nutcap-lifted) | community | 0.532 | 0.814 | 0.762 | 0.547 | 0.285 | 0.445 | 0.994 | 0.625 | 0.574 | +0.545 | 0.458 |
| 2 | OpenFOAM 12 (UMF) · \(\mathrm{Sc_t}\) 0.3 | Eddy3D | 0.506 | 0.747 | 0.762 | 0.515 | 0.244 | 0.468 | 0.985 | 0.604 | 0.586 | +0.519 | 0.455 |
| 3 | OpenFOAM 12 (UMF) · \(\mathrm{Sc_t}\) 0.5 | Eddy3D | 0.506 | 0.747 | 0.762 | 0.515 | 0.244 | 0.387 | 0.985 | 0.592 | 0.575 | +0.514 | 0.448 |
| 4 | OpenFOAM 12 (UMF) · \(\mathrm{Sc_t}\) 0.7 | Eddy3D | 0.506 | 0.747 | 0.762 | 0.515 | 0.244 | 0.358 | 0.985 | 0.588 | 0.563 | +0.511 | 0.444 |
All runs scored by validation/score_submissions.py. Ranked by mean hit rate (VDI 3783) over the tasks; bold: best per column. Not ranked: the ML surrogate (no point ids) and negative controls. Community rows are self-reported (Validate your own solver).