Case A: reference data

Contents
  1. Configuration
  2. Frame and units
  3. Reference data
  4. Columns
  5. Inflow
  6. Known data issues
  7. API
  8. Attribution
    1. Cite

Configuration

Parameter Value
Building 1:1:2 (width : depth : height) prism
Width b (m) 0.08
Height H (m) 0.16
Reynolds number \(\mathrm{Re_H}\) 24,000
\(U_H\) (m/s) 4.491
Wind directions (°) 0
Measurement planes vertical centre plane \(y/b = 0\), horizontal \(z/b = 0.125\), horizontal \(z/b = 1.25\)
Instrument hot-wire anemometer, split-fibre probes (DANTEC 55R55 streamwise, 55R57 spanwise/vertical), 1000 Hz, 60 s per point, 500 Hz low-pass
Wind tunnel Technical Research Institute, Shimizu Corporation, Tokyo
Scale, note model scale; Eddy3D solves it at 1:100 (\(b = 8\thinspace\mathrm{m}\), \(H = 16\thinspace\mathrm{m}\)) with the tunnel velocities
Nomenclature: symbols, columns and scores

Geometry, reference scales and release

  • \(H\), \(b\), \(D\) (m) — height of the building, cube, tower or tree belt; width of the building; edge of the cubes of Case C: the lengths the cases are drawn and normalised by
  • \(U_H\) (m/s) — reference speed: the mean approach-flow speed at the height \(H\) (each Data page gives the value used)
  • \(U_R\), \(H_R\), \(Z_R\) (m/s, m) — reference speed and height of a workbook: Case E, \(U_R\) at \(Z_R\) = 250 m full scale (1 m in the model); Case M, \(U_R\) and \(H_R\) at the reference point of the tunnel and of each field run
  • \(U_{\mathrm{ref}}\), \(L_{\mathrm{ref}}\) (m/s, m) — reference speed and length of a case’s normalisation: \(U_H\) and \(H\) (\(U_R\) and \(H_R\) in Case M); for the velocity ratios the approach speed at 15.9 m (Case E) or at 500 m (Case F)
  • \(U_b\) (m/s) — Case G: mean approach-flow speed at 9 m, the normalisation of its approach-flow table
  • \(q\), \(c_{\mathrm{gas}}\) (m³/s, ppm) — tracer release of the experiment: volume flow of the released gas, and its tracer content (\(10^6\) ppm when pure); \(Q\) is the source strength given to a solve
  • \(R_b\) (dimensionless) — bulk Richardson number of the heated-floor cases J and L (negative: unstable stratification)
  • \(\mathrm{Re_H}\), \(\mathrm{Re_D}\) (dimensionless) — Reynolds numbers \(U_H H/\nu\) and \(U_H D/\nu\) (\(\nu\): kinematic viscosity of air)
  • \(u_\ast\), \(z_0\), \(\kappa\) (m/s, mm, dimensionless) — friction velocity and roughness length of the log law fitted to the approach flow, and the von Kármán constant (0.41)
  • \(\mathrm{WD}\) (column wind_direction_deg; °) — wind direction (each frame says how it is counted); \(\mathrm{WD_R}\) is the mean direction of a field run at its reference point (Case M)
  • \(x\), \(y\), \(z\) (columns x, y, z; m) — coordinates in the case’s frame (\(+x\), \(+y\) and \(+z\) are the positive directions; each Data page says which way \(+x\) points), \(z\) up from the floor of the tunnel or from the ground
  • \(\mathrm{d}x\) (m) — lattice spacing of the OpenLB and FluidX3D runs, in metres or as a fraction of \(H\) (\(H/64\))
  • \(L_r\) (m) — reattachment length behind the building, read from a wake line at ground level; reported as \(L_r/H\)

Velocity and turbulence

  • \(U\), \(V\), \(W\) (columns U, V, W; m/s) — mean velocity along \(+x\), \(+y\), \(+z\); \(V\) is positive toward \(+y\) in every case
  • \(\lvert\mathbf{U}\rvert\) (m/s) — magnitude of the mean velocity vector, \(\sqrt{U^2+V^2+W^2}\)
  • \(V_{\mathrm{s}}\) (column Vs; m/s) — mean omnidirectional scalar speed of a thermistor (never a vector magnitude)
  • \(\overline{u'u'}\), \(\overline{v'v'}\), \(\overline{w'w'}\) (columns uu, vv, ww; m²/s²) — velocity variances (overbar: time average, prime: fluctuation about it)
  • \(\overline{u'v'}\), \(\overline{u'w'}\), \(\overline{v'w'}\) (columns uv, uw, vw; m²/s²) — Reynolds shear stresses
  • \(k = \tfrac{1}{2}\left(\overline{u'u'}+\overline{v'v'}+\overline{w'w'}\right)\) (column k; m²/s²) — turbulent kinetic energy
  • \(U/U_{\mathrm{ref}}\) (column velocity_ratio; dimensionless) — mean speed over the case’s reference speed (\(V_{\mathrm{s}}/U_{\mathrm{ref}}\) for a thermistor)
  • \(\sigma_{U/U_{\mathrm{ref}}}\) (column velocity_ratio_sd; dimensionless) — standard deviation of velocity_ratio over the observations behind a field value (Case F)
  • \(k/U_{\mathrm{ref}}^2\) (column k_ratio; dimensionless) — turbulent kinetic energy over the square of the reference speed, where only normalised values are published (Case G)

Concentration and temperature

  • \(C\) (column C; ppm) — mean tracer-gas concentration as published (volume fraction \(\times 10^6\) of the released gas diluted in air)
  • \(c_{\mathrm{rms}}\) (column c_rms; ppm) — root mean square of the concentration fluctuation
  • \(c_0\) (ppm) — reference concentration, defined for each case on its Data page: \(c_0 = \dfrac{c_{\mathrm{gas}}\thinspace q}{U_H H^2}\) (\(U_R H_R^2\) in the denominator in Case M)
  • \(c^\ast\) (column concentration_ratio; dimensionless) — dimensionless concentration \(c^\ast = C/c_0\); the value of a solve is \(c\thinspace U_H H^2/Q\) for its mean concentration \(c\) and its source strength \(Q\)
  • \(\mathrm{Sc_t}\) (dimensionless) — turbulent Schmidt number of a solve (0.3, 0.5 and 0.7)
  • \(T\), \(T_{\mathrm{rms}}\) (columns T, T_rms; °C, K) — mean air temperature as published (Cases J and L) and the root mean square of its fluctuation
  • \(\overline{u'c'}\), \(\overline{v'c'}\), \(\overline{w'c'}\) (columns uc, vc, wc; ppm·m/s) — turbulent concentration fluxes
  • \(\overline{u'\theta'}\), \(\overline{v'\theta'}\), \(\overline{w'\theta'}\) (columns uT, vT, wT; K·m/s) — turbulent heat fluxes (\(\theta'\): the temperature fluctuation)
  • \(\theta = \dfrac{T_f - T}{T_f - T_H}\) (dimensionless) — floor-referenced temperature the solves of Cases J and L are scored on: 0 at the floor, 1 in the approach air at \(H\); \(T_f\) is the floor temperature and \(T_H\) the temperature of the approach flow at \(H\)

Scores

  • \(n\) — number of pairs of a measured value \(o_i\) and a modelled value \(p_i\) at one point
  • \(R\) — Pearson correlation coefficient of the pairs
  • \(R^2\) — square of \(R\): share of the measured variance a linear fit to the model explains
  • \(\mathrm{FAC2}\) — fraction of pairs with \(0.5 \le p_i/o_i \le 2\)
  • \(\mathrm{FB}\) — fractional bias \(2(\overline{o}-\overline{p})/(\overline{o}+\overline{p})\), positive when the model is low
  • \(\mathrm{HR}\) (hit rate) — fraction of pairs with \(\lvert p_i-o_i\rvert/\lvert o_i\rvert \le \delta_{\mathrm{rel}}\) or \(\lvert p_i-o_i\rvert \le \delta_{\mathrm{abs}}\), where \(\delta_{\mathrm{rel}} = 0.25\) and \(\delta_{\mathrm{abs}} = 0.05\thinspace U_H\) for a velocity component
  • \(\mathrm{NMSE} = \dfrac{\overline{(o-p)^2}}{\overline{o}\thinspace \overline{p}}\) — normalised mean square error
  • \(\mathrm{NAD} = \dfrac{\overline{\lvert o-p\rvert}}{\overline{o}+\overline{p}}\) — normalised absolute difference
  • \(\mathrm{MG} = \exp\overline{(\ln o-\ln p)}\) — geometric mean bias
  • \(\mathrm{VG} = \exp\overline{(\ln o-\ln p)^2}\) — geometric variance
  • The ratio of \(\mathrm{FAC2}\) keeps its sign, so a model of the other sign than the measurement is a miss; \(\mathrm{FB}\), \(\mathrm{NMSE}\) and \(\mathrm{NAD}\) divide by the means, so they are undefined (shown as —) for a signed component unless the measured and the modelled mean are both positive
  • VDI 3783-9 calls the hit rate \(q\) and the tolerances \(D\) and \(W\); on this site those letters keep their other meanings (\(q\) the tracer release rate, \(D\) the block size of Case C, \(W\) the vertical velocity)
  • The detection limit of a concentration is one value per case, \(10^{-3}\) of the largest measured value. It sets \(\delta_{\mathrm{abs}}\) of the hit rate and the both-below rule of \(\mathrm{FAC2}\), and floors the values in \(\mathrm{MG}\) and \(\mathrm{VG}\).
  • The scores \(\mathrm{FB}\), \(\mathrm{FAC2}\), \(\mathrm{NMSE}\), \(\mathrm{NAD}\), \(\mathrm{MG}\) and \(\mathrm{VG}\) follow Chang & Hanna (2004); the hit rate follows VDI 3783-9.

Quantities scored

  • \(U\), \(V\) and \(W\) (mean velocity components) over \(U_H\)
  • \(k\) (turbulent kinetic energy) over \(U_H^2\)
  • the speed \(\lvert\mathbf{U}\rvert\) and \(\sqrt{\lvert\mathbf{U}\rvert^2+2k}\), against a thermistor’s \(V_{\mathrm{s}}\)
  • \(c^\ast = C/c_0\) (dimensionless concentration) at turbulent Schmidt numbers \(\mathrm{Sc_t}\) of 0.3, 0.5 and 0.7
  • \(\theta\) (floor-referenced temperature)

Frame and units

Property Definition
Origin building centre on the ground plane
x \(+x\) streamwise (the wind at \(\mathrm{WD} = 0\) blows toward \(+x\)); building spans \(x \in \lbrack -0.04,\thinspace 0.04\rbrack\)
y \(+y\) lateral; building spans \(y \in \lbrack -0.04,\thinspace 0.04\rbrack\); points published on the y <= 0 half by the tunnel's symmetry convention
z \(+z\) up from the ground; roof at \(z = 0.16\)
Lateral sign applied 1
Coordinate scale applied 1.0
Unit of length m (model scale)
Unit of velocity m/s
Unit of variance m²/s²
Unit of \(k\) m²/s²

Reference data

Source in this repository: raw/cases/case-a/RS-caseA.csv (approach flow: raw/cases/case-a/AF_caseA.csv).

The cleaned table has 186 rows over 186 distinct points; columns point_id, config, instrument, wind_direction_deg, x, y, z, U, V, W, uu, vv, ww, k, campaign.

Configuration Points
default, WD 0° 186

Columns

The columns of the cleaned table (points.csv, points.json), in order.

The 15 columns and what each holds
Column Symbol Meaning
point_id   the tunnel's own measurement point number
config   configuration key: 'default', Case C centre building '0D'/'1D'/'2D', Case E state 'bc' (before) / 'ac' (after construction)
instrument   'split_fibre' (vector components) or 'thermistor' (omnidirectional scalar speed)
wind_direction_deg   AIJ wind direction in degrees; 0 is the case's reference direction (see frame)
x   m, case frame
y   m, case frame
z   m above ground, case frame
U \(U\) m/s, mean velocity along \(+x\)
V \(V\) m/s, mean velocity along \(+y\) (sign unified: positive toward \(+y\))
W \(W\) m/s, mean velocity along \(+z\)
uu \(\overline{u'u'}\) m²/s², variance of u
vv \(\overline{v'v'}\) m²/s², variance of v
ww \(\overline{w'w'}\) m²/s², variance of w
k \(k\) m²/s², turbulent kinetic energy
campaign   'wind_tunnel' (model scale) or 'field' (a full-scale observation: Cases F, G, M)

Inflow

Property Value
Method log law, \(\kappa\) = 0.41, least squares over \(z = 0.02\thinspace\ldots\thinspace 2H\) on the case's own approach-flow file
Friction velocity \(u_\ast\) (m/s) 0.343
Roughness length \(z_0\) (mm) 0.668
\(U_H\), measured (m/s) 4.491
Log-law error at H +2.0 %

Known data issues

  • Lateral velocity \(V\) is positive toward \(+y\) (checked: \(V\) = -2.893 m/s at (-0.040, -0.050, 0.010), just outside the \(y \lt 0\) side face, deflecting away from the centreline). Case B uses the OPPOSITE sign; the API flips Case B so both agree.
  • Coordinates are metres (Case B's are millimetres in the published file).
  • Case A's turbulence columns are rms values (\(u_{\mathrm{rms}}\), …). The API serves VARIANCES (\(\overline{u'u'} = u_{\mathrm{rms}}^2\)) so A and B share one column meaning.

API

Attribution

  • Data collected by Takeshi Ishihara (The University of Tokyo) and Kazuki Hibi (Numerical Flow Design).
  • Edited and distributed by Yoshihide Tominaga (Niigata Institute of Technology), Hideki Kikumoto (The University of Tokyo) and Tsubasa Okaze (Institute of Science Tokyo).
  • DOI: 10.5281/zenodo.15050147
  • Citation requested: Meng, Y., & Hibi, K. (1998). Turbulent measurements of the flow field around a high-rise building. Journal of Wind Engineering, JAWE, 76, 55-64. https://doi.org/10.5359/jawe.1998.76_55
  • Licence: CC BY 4.0

Cite

APA

Ishihara, T., Hibi, K., Tominaga, Y., Kikumoto, H., & Okaze, T. (2025). AIJ UWE Benchmark Dataset – Case A (112): Wind Tunnel Experiment for Flow around a 1:1:2 Shape Building Model [Data set]. Zenodo. https://doi.org/10.5281/zenodo.15050147

BibTeX

@misc{aijuwe_case_a,
  author    = "Ishihara, Takeshi and Hibi, Kazuki and Tominaga, Yoshihide and Kikumoto, Hideki and Okaze, Tsubasa",
  title     = "{AIJ UWE Benchmark Dataset -- Case A (112): Wind Tunnel Experiment for Flow around a 1:1:2 Shape Building Model}",
  year      = "2025",
  publisher = "Zenodo",
  doi       = "10.5281/zenodo.15050147",
  url       = "https://doi.org/10.5281/zenodo.15050147",
  note      = "Data set"
}

API: see About.