Case J: validation

Contents
  1. Measurement locations
  2. Explore the points
  3. OpenFOAM 12
    1. Measured against modelled
    2. Vertical profiles
    3. Field maps
    4. urbanMicroclimateFoam, realizable k-epsilon (Eddy3D Outdoor+)
    5. urbanMicroclimateFoam, buoyantKEpsilon (Eddy3D Outdoor+)
  4. Not run
  5. Notes on every run
  6. Leaderboard

Engine status: OpenFOAM 12 (UMF) scored · OpenFOAM 12 (UMF) buoyantKEpsilon scored · OpenLB pending · FluidX3D pending · ML surrogate pending

Nomenclature: symbols, columns and scores

Geometry, reference scales and release

  • \(H\), \(b\), \(D\) (m) — height of the building, cube, tower or tree belt; width of the building; edge of the cubes of Case C: the lengths the cases are drawn and normalised by
  • \(U_H\) (m/s) — reference speed: the mean approach-flow speed at the height \(H\) (each Data page gives the value used)
  • \(U_R\), \(H_R\), \(Z_R\) (m/s, m) — reference speed and height of a workbook: Case E, \(U_R\) at \(Z_R\) = 250 m full scale (1 m in the model); Case M, \(U_R\) and \(H_R\) at the reference point of the tunnel and of each field run
  • \(U_{\mathrm{ref}}\), \(L_{\mathrm{ref}}\) (m/s, m) — reference speed and length of a case’s normalisation: \(U_H\) and \(H\) (\(U_R\) and \(H_R\) in Case M); for the velocity ratios the approach speed at 15.9 m (Case E) or at 500 m (Case F)
  • \(U_b\) (m/s) — Case G: mean approach-flow speed at 9 m, the normalisation of its approach-flow table
  • \(q\), \(c_{\mathrm{gas}}\) (m³/s, ppm) — tracer release of the experiment: volume flow of the released gas, and its tracer content (\(10^6\) ppm when pure); \(Q\) is the source strength given to a solve
  • \(R_b\) (dimensionless) — bulk Richardson number of the heated-floor cases J and L (negative: unstable stratification)
  • \(\mathrm{Re_H}\), \(\mathrm{Re_D}\) (dimensionless) — Reynolds numbers \(U_H H/\nu\) and \(U_H D/\nu\) (\(\nu\): kinematic viscosity of air)
  • \(u_\ast\), \(z_0\), \(\kappa\) (m/s, mm, dimensionless) — friction velocity and roughness length of the log law fitted to the approach flow, and the von Kármán constant (0.41)
  • \(\mathrm{WD}\) (column wind_direction_deg; °) — wind direction (each frame says how it is counted); \(\mathrm{WD_R}\) is the mean direction of a field run at its reference point (Case M)
  • \(x\), \(y\), \(z\) (columns x, y, z; m) — coordinates in the case’s frame (\(+x\), \(+y\) and \(+z\) are the positive directions; each Data page says which way \(+x\) points), \(z\) up from the floor of the tunnel or from the ground
  • \(\mathrm{d}x\) (m) — lattice spacing of the OpenLB and FluidX3D runs, in metres or as a fraction of \(H\) (\(H/64\))
  • \(L_r\) (m) — reattachment length behind the building, read from a wake line at ground level; reported as \(L_r/H\)

Velocity and turbulence

  • \(U\), \(V\), \(W\) (columns U, V, W; m/s) — mean velocity along \(+x\), \(+y\), \(+z\); \(V\) is positive toward \(+y\) in every case
  • \(\lvert\mathbf{U}\rvert\) (m/s) — magnitude of the mean velocity vector, \(\sqrt{U^2+V^2+W^2}\)
  • \(V_{\mathrm{s}}\) (column Vs; m/s) — mean omnidirectional scalar speed of a thermistor (never a vector magnitude)
  • \(\overline{u'u'}\), \(\overline{v'v'}\), \(\overline{w'w'}\) (columns uu, vv, ww; m²/s²) — velocity variances (overbar: time average, prime: fluctuation about it)
  • \(\overline{u'v'}\), \(\overline{u'w'}\), \(\overline{v'w'}\) (columns uv, uw, vw; m²/s²) — Reynolds shear stresses
  • \(k = \tfrac{1}{2}\left(\overline{u'u'}+\overline{v'v'}+\overline{w'w'}\right)\) (column k; m²/s²) — turbulent kinetic energy
  • \(U/U_{\mathrm{ref}}\) (column velocity_ratio; dimensionless) — mean speed over the case’s reference speed (\(V_{\mathrm{s}}/U_{\mathrm{ref}}\) for a thermistor)
  • \(\sigma_{U/U_{\mathrm{ref}}}\) (column velocity_ratio_sd; dimensionless) — standard deviation of velocity_ratio over the observations behind a field value (Case F)
  • \(k/U_{\mathrm{ref}}^2\) (column k_ratio; dimensionless) — turbulent kinetic energy over the square of the reference speed, where only normalised values are published (Case G)

Concentration and temperature

  • \(C\) (column C; ppm) — mean tracer-gas concentration as published (volume fraction \(\times 10^6\) of the released gas diluted in air)
  • \(c_{\mathrm{rms}}\) (column c_rms; ppm) — root mean square of the concentration fluctuation
  • \(c_0\) (ppm) — reference concentration, defined for each case on its Data page: \(c_0 = \dfrac{c_{\mathrm{gas}}\thinspace q}{U_H H^2}\) (\(U_R H_R^2\) in the denominator in Case M)
  • \(c^\ast\) (column concentration_ratio; dimensionless) — dimensionless concentration \(c^\ast = C/c_0\); the value of a solve is \(c\thinspace U_H H^2/Q\) for its mean concentration \(c\) and its source strength \(Q\)
  • \(\mathrm{Sc_t}\) (dimensionless) — turbulent Schmidt number of a solve (0.3, 0.5 and 0.7)
  • \(T\), \(T_{\mathrm{rms}}\) (columns T, T_rms; °C, K) — mean air temperature as published (Cases J and L) and the root mean square of its fluctuation
  • \(\overline{u'c'}\), \(\overline{v'c'}\), \(\overline{w'c'}\) (columns uc, vc, wc; ppm·m/s) — turbulent concentration fluxes
  • \(\overline{u'\theta'}\), \(\overline{v'\theta'}\), \(\overline{w'\theta'}\) (columns uT, vT, wT; K·m/s) — turbulent heat fluxes (\(\theta'\): the temperature fluctuation)
  • \(\theta = \dfrac{T_f - T}{T_f - T_H}\) (dimensionless) — floor-referenced temperature the solves of Cases J and L are scored on: 0 at the floor, 1 in the approach air at \(H\); \(T_f\) is the floor temperature and \(T_H\) the temperature of the approach flow at \(H\)

Scores

  • \(n\) — number of pairs of a measured value \(o_i\) and a modelled value \(p_i\) at one point
  • \(R\) — Pearson correlation coefficient of the pairs
  • \(R^2\) — square of \(R\): share of the measured variance a linear fit to the model explains
  • \(\mathrm{FAC2}\) — fraction of pairs with \(0.5 \le p_i/o_i \le 2\)
  • \(\mathrm{FB}\) — fractional bias \(2(\overline{o}-\overline{p})/(\overline{o}+\overline{p})\), positive when the model is low
  • \(\mathrm{HR}\) (hit rate) — fraction of pairs with \(\lvert p_i-o_i\rvert/\lvert o_i\rvert \le \delta_{\mathrm{rel}}\) or \(\lvert p_i-o_i\rvert \le \delta_{\mathrm{abs}}\), where \(\delta_{\mathrm{rel}} = 0.25\) and \(\delta_{\mathrm{abs}} = 0.05\thinspace U_H\) for a velocity component
  • \(\mathrm{NMSE} = \dfrac{\overline{(o-p)^2}}{\overline{o}\thinspace \overline{p}}\) — normalised mean square error
  • \(\mathrm{NAD} = \dfrac{\overline{\lvert o-p\rvert}}{\overline{o}+\overline{p}}\) — normalised absolute difference
  • \(\mathrm{MG} = \exp\overline{(\ln o-\ln p)}\) — geometric mean bias
  • \(\mathrm{VG} = \exp\overline{(\ln o-\ln p)^2}\) — geometric variance
  • The ratio of \(\mathrm{FAC2}\) keeps its sign, so a model of the other sign than the measurement is a miss; \(\mathrm{FB}\), \(\mathrm{NMSE}\) and \(\mathrm{NAD}\) divide by the means, so they are undefined (shown as —) for a signed component unless the measured and the modelled mean are both positive
  • VDI 3783-9 calls the hit rate \(q\) and the tolerances \(D\) and \(W\); on this site those letters keep their other meanings (\(q\) the tracer release rate, \(D\) the block size of Case C, \(W\) the vertical velocity)
  • The detection limit of a concentration is one value per case, \(10^{-3}\) of the largest measured value. It sets \(\delta_{\mathrm{abs}}\) of the hit rate and the both-below rule of \(\mathrm{FAC2}\), and floors the values in \(\mathrm{MG}\) and \(\mathrm{VG}\).
  • The scores \(\mathrm{FB}\), \(\mathrm{FAC2}\), \(\mathrm{NMSE}\), \(\mathrm{NAD}\), \(\mathrm{MG}\) and \(\mathrm{VG}\) follow Chang & Hanna (2004); the hit rate follows VDI 3783-9.

Quantities scored

  • \(U\), \(V\) and \(W\) (mean velocity components) over \(U_H\)
  • \(k\) (turbulent kinetic energy) over \(U_H^2\)
  • the speed \(\lvert\mathbf{U}\rvert\) and \(\sqrt{\lvert\mathbf{U}\rvert^2+2k}\), against a thermistor’s \(V_{\mathrm{s}}\)
  • \(c^\ast = C/c_0\) (dimensionless concentration) at turbulent Schmidt numbers \(\mathrm{Sc_t}\) of 0.3, 0.5 and 0.7
  • \(\theta\) (floor-referenced temperature)

Measurement locations

Measurement lines and planes, Case J
Figure 1. Case J, measurement lines and planes: A vertical profiles, \(y/H = 0\); B plane \(z/H = 0.025\); C plane \(z/H = 0.25\). Positions in multiples of \(H\).

Explore the points

model lowmodel high
Loading the points… Hover a point to see where it sits in 3D and how the model differs from the measurement; click to pin it. This needs JavaScript; the figures on this page show the same scores.

OpenFOAM 12

Status: scored

Case J is non-isothermal: a floor held at 45.8 °C under a cooler approach flow (bulk Richardson number −0.086), with an ethylene tracer released from the floor. Eddy3D solved it with its buoyant microclimate engine, urbanMicroclimateFoam (UMF, the Outdoor+ plugin), an OpenFOAM 12 solver developed at ETH Zurich and Empa (its engine ids are on the Validation overview; Eddy3D owns none of its physics). The isothermal OpenFOAM 12 solver was not run on this case.

  • What each run is. Solved on 2026-10-18. The 1:1:2 building on a floor 33.6 K warmer than the approach air at building height, 236,408 air cells, under UMF’s two closures, realizable k-ε (the shipped one) and buoyantKEpsilon (which carries the buoyancy production the neutral closure lacks); two engine ids, umf-realizableKE and umf-buoyantKEpsilon. The air region stopped at its 1500-iteration cap with the residual control unmet; at the last iteration the initial residuals of \(U_y\) and p_rgh were of the order of \(10^{-2}\) and those of the tracers \(10^{-3}\). Solved on one mesh, with a steady tracer solved beside the flow as three species (turbulent Schmidt numbers 0.3, 0.5 and 0.7, all published).
  • Froude scale. The production case writer cannot mesh the tunnel model, so the scene is the tunnel scaled by 62.5: lengths times the scale, velocities times its square root, temperatures unchanged. The Richardson number, Pr and the Kelvin values are kept; the Reynolds number is not (\(1.6 \times 10^{4}\) in the tunnel, \(8 \times 10^{6}\) in the scene). Every pair is in the tunnel’s units: coordinates divided by the scale, velocities by the scene’s \(U_H\), \(k\) by its square.
  • Temperature is scored as the floor-referenced fraction \(\theta = (T_f - T)/(T_f - T_H)\), 0 at the floor and 1 in the approach air at the building height (the workbook’s own normalisation). \(\theta\) lies between 0.4 and 1.1. The temperature errors in kelvin are in the files (temperature.all).
  • Concentration is the measured \(C/c_0\) (\(c_0\) = 12.28 ppm) against the model’s ethylene mass fraction as ppm over the same \(c_0\), with one detection limit of \(10^{-3}\) of the largest measured value.
  • Measured side. Point 153 repeats point 1 (the crossing of two planes, identical values) and is left out: 443 points.
  • Tracer mass balance. The outlet carried 0.62 to 0.95 (0.89, 0.75 and 0.62 under rk-ε; 0.95, 0.84 and 0.73 under bKε, for \(\mathrm{Sc_t}\) 0.3, 0.5 and 0.7) of the emission.
  • FB is positive when the model is low, and is left out (—) for a signed component whose measured and modelled means are not both positive.
Interpretation: Engine, scale and temperature scoring
  • The isothermal OpenFOAM 12 solver Eddy3D uses for the other cases cannot represent a heated floor, which is why this case was solved with UMF.
  • Temperature FAC2 is 1.00 almost everywhere because \(\theta\) lies between 0.4 and 1.1, so R and the hit rate carry the comparison.
  • The Froude scale keeps the Richardson number, Pr and the Kelvin values and changes the Reynolds number, so the wall-function regime of the model differs from the tunnel’s.

Measured against modelled

Case J, measured vs modelled velocity, k and temperature
Figure 2. Case J under realizable k-ε (top) and buoyantKEpsilon (bottom): measured vs modelled \(U\), \(W\), \(k\) and the floor-referenced temperature \(\theta\); the dots take the colour of the line or plane they were measured on, as in Figure 1.
Quantity R (rk-ε) FAC2 FB R (bKε) FAC2 FB
\(U\) +0.921 0.731 +0.193 +0.924 0.761 +0.167
\(V\) +0.866 0.449 — +0.901 0.442 —
\(W\) +0.840 0.289 — +0.849 0.289 —
\(k\) +0.322 0.558 −0.034 +0.360 0.582 −0.088
\(\theta\) +0.922 1.000 +0.120 +0.920 0.998 +0.127
\(c^\ast\), \(\mathrm{Sc_t}\) 0.3 +0.919 0.858 +0.065 +0.894 0.869 −0.050
\(c^\ast\), \(\mathrm{Sc_t}\) 0.5 +0.905 0.847 −0.162 +0.869 0.840 −0.274
\(c^\ast\), \(\mathrm{Sc_t}\) 0.7 +0.896 0.828 −0.256 +0.852 0.806 −0.380
\(c^\ast\), \(\mathrm{Sc_t}\) 0.3, without the near-source points +0.874 0.760 +0.240 +0.829 0.757 +0.052
\(c^\ast\), \(\mathrm{Sc_t}\) 0.5, without the near-source points +0.860 0.752 +0.067 +0.788 0.731 −0.193
\(c^\ast\), \(\mathrm{Sc_t}\) 0.7, without the near-source points +0.848 0.728 +0.025 +0.755 0.709 −0.292

n is 443 (416 without the 27 points within a quarter of a building height of the source); rk-ε is realizable k-ε and bKε is buoyantKEpsilon.

  • Flow. \(U\): \(R = 0.92\) under both closures, FAC2 0.73 and 0.76; the mean \(U/U_H\) is 0.465 and 0.477 modelled against 0.564 measured. FB in the wake (rk-ε and bKε): +0.36 and +0.29 in the near wake, +0.48 and +0.43 in the far wake. Reattachment at \(z/H = 0.25\text{ and }0.025\) is \(1.35\thinspace H\) and \(1.35\thinspace H\) (rk-ε) or \(1.35\thinspace H\) and \(1.56\thinspace H\) (bKε), against the measured \(0.68\thinspace H\) and \(0.80\thinspace H\). Scored against the mean of each mirror pair, the measurement has \(R = 0.99\) for \(U\); the \(+y\) half of the \(z/H = 0.25\) plane is 11 % slower than the \(-y\) half (97 pairs, R 0.955).
  • \(k\). R is 0.32 and 0.36; the means are 0.030 and 0.031 modelled, 0.029 measured.
  • Temperature. \(\theta\): \(R = 0.92\) and hit rate 0.82 and 0.81. In kelvin the mean bias is +3.46 K (rk-ε) and +3.63 K (bKε), the root-mean-square error 4.53 K and 4.80 K, \(R = 0.92\). The model’s first cell is 12 mm at tunnel scale; the tunnel’s 24 K drop between the floor and the first measurement at 3 mm lies inside it.
  • Tracer. R is 0.92 to 0.90 (rk-ε) and 0.89 to 0.85 (bKε) from \(\mathrm{Sc_t}\) 0.3 to 0.7. Under rk-ε the model is low at \(\mathrm{Sc_t}\) 0.3 (FB +0.065) and high at 0.5 and 0.7 (−0.162, −0.256). The modelled peak at the measured points is 275, 339 and 373 against a measured peak of 437. By region at \(\mathrm{Sc_t}\) 0.5 under rk-ε (R, FAC2): above the roof +0.78 and 0.33 (75 points), beside the building +0.82 and 0.40 (60), the near wake +0.90 and 0.75 (168), the far wake +0.89 and 0.82 (56), upstream −0.18 and 0.05 (84). Upstream the tunnel measures a background of 0.018 \(c_0\) on average (about 0.2 ppm, below the workbook’s expanded uncertainty noted in the known data issues) and the model has a mean of \(4 \times 10^{-5}\) \(c_0\) and a largest value of \(1.4 \times 10^{-3}\) at \(\mathrm{Sc_t}\) 0.5 under rk-ε.
  • Closures compared. buoyantKEpsilon against realizable k-ε: \(U\)’s R 0.924 against 0.921, \(U\)’s FAC2 0.761 against 0.731, \(k\)’s R 0.36 against 0.32. The tracer’s R is lower by 0.025 to 0.044 and FB lower by 0.11 to 0.12.
Interpretation: Case J flow, temperature and tracer
  • The flow is reproduced in pattern and low in level. The deficit is largest in the wake. The steady closures give a recirculation that is too long.
  • The tunnel’s mirror-pair ceiling (\(R = 0.99\)) is above the model’s R of 0.92.
  • \(k\) is not reproduced. The means are close, so the agreement in FB is not agreement in pattern.
  • The model is warmer than the tunnel. Near-floor temperature is a wall-function result, because the tunnel’s 24 K drop lies inside the model’s first cell.
  • The tracer pattern is correlated at every Schmidt number, and the bias changes sign. The near-source points are low; in Cases H and K they are high.
  • Upstream, FAC2 is small whatever the model does, because the tunnel measures a background the model has almost none of.
  • The two closures differ little in the flow and more in the tracer: the modelled concentration is higher under buoyantKEpsilon. This ranks two closures on one building, one mesh and a run capped at 1500 iterations.
Case J, measured vs modelled tracer concentration
Figure 3. Case J, dots coloured as in Figure 1: measured vs modelled \(c^\ast\) at three turbulent Schmidt numbers under both closures. The concentration panels show the positive pairs within seven decades; the points within a quarter of a building height of the source are open.

Vertical profiles

Where along the height the model meets the measurement, station by station.

Vertical profiles, Case J
Figure 4. Case J, vertical profiles of \(U/U_H\) on the centre plane \(y = 0\) at four stations along the measured lines, measured points against the modelled line, offset by 1 per station; the dashed line is the roof height.

Field maps

The solved velocity on the measured planes, every point drawn on it as a dot coloured by its measured value on the same scale: a dot that stands out from the colour around it is a point the model misses.

Solved field and measured points, Case J, plan
Figure 5. Case J, the horizontal plane \(z = 0.04\thinspace\mathrm{m}\): (a) \(u\) over \(U_H\); (b) the same with iso-lines every 0.1 and the edge of the reversed flow, \(u = 0\), dashed; (c) the in-plane speed with streamlines.
Solved field and measured points, Case J, section
Figure 6. Case J, the centre plane \(y = 0\): (a) \(u\) over \(U_H\); (b) the same with iso-lines every 0.1 and the edge of the reversed flow, \(u = 0\), dashed; (c) the in-plane speed with streamlines.

urbanMicroclimateFoam, realizable k-epsilon (Eddy3D Outdoor+)

Score R \(R^2\) FAC2 FB Hit rate n
\(U\) +0.921 0.847 0.731 +0.193 0.573 443
\(V\) +0.866 0.750 0.449 — 0.526 443
\(W\) +0.840 0.706 0.289 — 0.596 443
\(k\) +0.322 0.104 0.558 -0.034 0.178 443
\(\theta\), floor-referenced temperature +0.922 0.850 1.000 +0.120 0.817 443
\(c^\ast\), \(\mathrm{Sc_t}\) 0.3 +0.919 0.844 0.858 +0.065 0.716 443
\(c^\ast\), \(\mathrm{Sc_t}\) 0.5 +0.905 0.819 0.847 -0.162 0.709 443
\(c^\ast\), \(\mathrm{Sc_t}\) 0.7 +0.896 0.803 0.828 -0.256 0.686 443
\(c^\ast\), \(\mathrm{Sc_t}\) 0.3, without the near-source points +0.874 0.764 0.760 +0.240 0.570 416
\(c^\ast\), \(\mathrm{Sc_t}\) 0.5, without the near-source points +0.860 0.740 0.752 +0.067 0.567 416
\(c^\ast\), \(\mathrm{Sc_t}\) 0.7, without the near-source points +0.848 0.719 0.728 +0.025 0.565 416
\(U\), y-symmetric ceiling (control) +0.993 0.987 0.971 +0.000 0.925 346
  • Per-point values: /api/cases/J/pairs/umf-realizableKE.csv
  • Reproduce: Eddy3D fixture MetaFOAM.Lib.Tests/TestAijCaseJUmfContainerE2E (1:1:2 building, heated floor, floor point source; urbanMicroclimateFoam, realizable k-ε, 236,408 air cells at Froude scale 62.5, 1500 air iterations, solved 2026-10-18); figures validation/plot_cases_jl_umf.py

Notes:

  • The tracer is solved steady beside the flow, as three species of one flow. The outlet carried 0.89, 0.75 and 0.62 of the emission for \(\mathrm{Sc_t}\) 0.3, 0.5 and 0.7, within the factor of two accepted as a check on the wiring.
  • The air region ended at its 1500-iteration cap with the residualControl unmet (no 'solution converged' line); at the last iteration the initial residuals were 1.3e-2 (\(U_y\)), 1.5e-2 (p_rgh) and 1.1e-3 to 1.7e-3 (the tracers).
  • The steady closure gives a longer recirculation than the tunnel: reattachment at \(z/H = 0.25\text{ and }0.025\) is \(1.35\thinspace H\) and \(1.35\thinspace H\), against the measured \(0.68\thinspace H\) and \(0.80\thinspace H\).

urbanMicroclimateFoam, buoyantKEpsilon (Eddy3D Outdoor+)

Score R \(R^2\) FAC2 FB Hit rate n
\(U\) +0.924 0.854 0.761 +0.167 0.607 443
\(V\) +0.901 0.812 0.442 — 0.540 443
\(W\) +0.849 0.720 0.289 — 0.587 443
\(k\) +0.360 0.129 0.582 -0.088 0.208 443
\(\theta\), floor-referenced temperature +0.920 0.846 0.998 +0.127 0.806 443
\(c^\ast\), \(\mathrm{Sc_t}\) 0.3 +0.894 0.798 0.869 -0.050 0.698 443
\(c^\ast\), \(\mathrm{Sc_t}\) 0.5 +0.869 0.755 0.840 -0.274 0.675 443
\(c^\ast\), \(\mathrm{Sc_t}\) 0.7 +0.852 0.725 0.806 -0.380 0.641 443
\(c^\ast\), \(\mathrm{Sc_t}\) 0.3, without the near-source points +0.829 0.687 0.757 +0.052 0.541 416
\(c^\ast\), \(\mathrm{Sc_t}\) 0.5, without the near-source points +0.788 0.622 0.731 -0.193 0.538 416
\(c^\ast\), \(\mathrm{Sc_t}\) 0.7, without the near-source points +0.755 0.570 0.709 -0.292 0.519 416
\(U\), y-symmetric ceiling (control) +0.993 0.987 0.971 +0.000 0.925 346
  • Per-point values: /api/cases/J/pairs/umf-buoyantKEpsilon.csv
  • Reproduce: Eddy3D fixture MetaFOAM.Lib.Tests/TestAijCaseJUmfContainerE2E (1:1:2 building, heated floor, floor point source; urbanMicroclimateFoam, buoyantKEpsilon, 236,408 air cells at Froude scale 62.5, 1500 air iterations, solved 2026-10-18); figures validation/plot_cases_jl_umf.py

Notes:

  • The tracer is solved steady beside the flow, as three species of one flow. The outlet carried 0.95, 0.84 and 0.73 of the emission for \(\mathrm{Sc_t}\) 0.3, 0.5 and 0.7, within the factor of two accepted as a check on the wiring.
  • The air region ended at its 1500-iteration cap with the residualControl unmet (no 'solution converged' line); at the last iteration the initial residuals were 1.3e-2 (\(U_y\)), 1.1e-2 (p_rgh) and 1.2e-3 to 1.6e-3 (the tracers).
  • The steady closure gives a longer recirculation than the tunnel: reattachment at \(z/H = 0.25\text{ and }0.025\) is \(1.35\thinspace H\) and \(1.56\thinspace H\), against the measured \(0.68\thinspace H\) and \(0.80\thinspace H\).

Not run

  • A second mesh, a longer iteration count and a transient run.
  • OpenLB, FluidX3D and the ML surrogate.
  • Not represented in the model (Eddy3D’s list): the release momentum and the gas’s own heat; the tunnel’s side walls and ceiling (slip here); radiation (emissivity 0.01, effectively off); the measured 4 K gradient up the building’s walls.
Interpretation: Limits of these runs
  • The air region reached its cap with residuals near \(10^{-2}\), so these numbers are those of an unconverged steady solve on one mesh.
  • The tracer balance closes within a factor of two; why part of the emission is missing at the outlet was not investigated.

Notes on every run

  • Quantity: \(U\), \(V\), \(W\) over \(U_H\) = 1.4581 m/s and \(k\) over \(U_H^2\) (the tunnel's units, 443 distinct points); theta = (\(T_f - T\))/(\(T_f - T_H\)) with \(T_f\) = 318.95 K and \(T_H\) = 285.32 K; \(c^\ast = C/c_0\) (\(c_0\) = 12.28 ppm) against the model's ethylene mass fraction as ppm over the same \(c_0\), for turbulent Schmidt numbers 0.3, 0.5 and 0.7; the 27 points within a quarter of a building height of the source are scored with and without. The scene is the tunnel at Froude scale 62.5
  • Normalisation: the tunnel's units: velocities by \(U_H\) (1.4581 m/s measured, the Froude-scaled 11.53 m/s modelled), \(k\) by \(U_H^2\), temperature as theta = (\(T_f - T\))/(\(T_f - T_H\)) (\(T_f\) = 45.8 degC, \(T_f - T_H\) = 33.63 K), \(c^\ast = C/c_0\) (\(c_0\) = 12.28 ppm) against the modelled ethylene mass fraction as ppm over the same \(c_0\); hit rate \(\delta_{\mathrm{rel}} = 0.25\), \(\delta_{\mathrm{abs}} = 0.05\) in those units, concentration with one detection limit of \(10^{-3}\) of the largest measured value; 443 points (point 153 repeats point 1)

Notes:

  • The scene is the tunnel at Froude scale 62.5 (the production case writer cannot mesh a 0.16 m building): lengths times 62.5, velocities times 7.9, temperatures unchanged. That keeps the bulk Richardson number (-0.0856), Pr, the tunnel's Kelvin values and the dimensionless tracer, and does not keep Re (1.6e4 in the tunnel, 8e6 here).
  • UMF's first cell is 0.75 m, 12 mm at tunnel scale: the tunnel's 24 K drop in air temperature between the floor and the first measurement at 3 mm lies inside it. The source is a mass rate into one pair of cells, with no release momentum and no heat from the 30.4 degC gas. The 27 points within a quarter of a building height of the source are scored with and without.
  • The building is not adiabatic here: its walls are held at the measured mean surface temperature, 297.62 K, and the measured 4 K vertical gradient up the walls is not modelled. There is no sun, and the radiation exchange is at the least the view-factor model accepts (air-side emissivity 0.01).
  • The measured \(+y\) half of the \(z/H = 0.25\) plane runs 11 % slower than the -y half (97 mirror pairs, R 0.955, recomputed from the cleaned table): the y-symmetric ceiling control scores the measurement against the mean of each mirror pair.
  • The wake recirculates behind the leeward face and reattaches within \(3\thinspace H\); the approach layer is unstable and the first cell above the heated floor is warmer than the air that entered it; every species is emitted, with clean air 25 m ahead of the building and its maximum at the source, and leaves through the outlet at 0.5 to 2 times the emission.
Interpretation: Case J wall functions

At the model's Re, UMF's wall functions belong and the tunnel's laminar-sublayer heat transfer does not exist. Near-floor temperature is a wall-function result, and the data's tracer peak 4 mm above the 5 mm hole is a source-cell-limited number.

How the scores are computed
  • Scores recomputed from the pairs by validation/dispersion_metrics.py; the SHA-256 of every file the snapshot was read from is in its results file, under sources.

Leaderboard

Rank Run Source Hit rate, \(U\) Hit rate, \(V\) Hit rate, \(W\) Hit rate, \(\lvert\mathbf{U}\rvert\) Hit rate, \(k\) Hit rate, \(c^\ast\) Hit rate, \(\theta\) Hit rate FAC2 R \(R^2\) Points scored
1 OpenFOAM 12 (UMF) buoyantKEpsilon · \(\mathrm{Sc_t}\) 0.3 Eddy3D 0.607 0.540 0.587 0.637 0.208 0.698 0.806 0.583 0.684 +0.820 0.707 100 %
2 OpenFOAM 12 (UMF) buoyantKEpsilon · \(\mathrm{Sc_t}\) 0.5 Eddy3D 0.607 0.540 0.587 0.637 0.208 0.675 0.806 0.580 0.679 +0.816 0.701 100 %
3 OpenFOAM 12 (UMF) · \(\mathrm{Sc_t}\) 0.3 Eddy3D 0.573 0.526 0.596 0.637 0.178 0.716 0.817 0.578 0.675 +0.811 0.698 100 %
4 OpenFOAM 12 (UMF) · \(\mathrm{Sc_t}\) 0.5 Eddy3D 0.573 0.526 0.596 0.637 0.178 0.709 0.817 0.577 0.674 +0.809 0.694 100 %
5 OpenFOAM 12 (UMF) buoyantKEpsilon · \(\mathrm{Sc_t}\) 0.7 Eddy3D 0.607 0.540 0.587 0.637 0.208 0.641 0.806 0.575 0.675 +0.814 0.697 100 %
6 OpenFOAM 12 (UMF) · \(\mathrm{Sc_t}\) 0.7 Eddy3D 0.573 0.526 0.596 0.637 0.178 0.686 0.817 0.573 0.671 +0.807 0.692 100 %

All runs scored by validation/score_submissions.py. Ranked by mean hit rate (VDI 3783) over the tasks; bold: best per column. Points scored: share of measured points with values. Not ranked: the ML surrogate (no point ids) and negative controls. Community rows are self-reported (Validate your own solver).