Case F: reference data

Contents
  1. Configuration
  2. Frame and units
  3. Reference data
  4. Columns
  5. Inflow
  6. Known data issues
  7. API
  8. Attribution
    1. Cite

Configuration

Parameter Value
District Shinjuku sub-centre during construction of the high-rise group, building configuration of November 1978
Scale 1:800
model terrain and buildings in a disc of radius 725 m (BD_caseF.stl; the readme and the data paper say 800 m / 1600 m diameter)
Points 13
point numbers 1-3, 5-11, 13-15 (4 and 12 absent; points 16 and later belong to later construction stages and are not in the dataset)
Wind directions N, NNE, NE, ENE, SE, SSE, S, SSW, SW, WNW, NW, NNW
wind directions field N, NNE, NE, ENE, E, ESE, SE, SSE, S, SSW, SW, WSW, \(W\), WNW, NW, NNW
measurement planes above ground m 5, 9, 20
measurement planes z m 15, 19, 30
ground offset m 10
Normalisation velocity ratio = mean speed / the approaching mean speed at the boundary-layer height 500 m (full scale); the field values were converted to it with the tunnel (readme). \(U(500\text{ m})\) is 10 m/s in the data paper and 10.65 m/s implied by the profile
Instrument tunnel: thermistor anemometer, 30 s averaging; field: three-cup anemometer with wind vane, 10-minute means above 5 m/s at the reference roof, December 1977 - November 1978
Wind tunnel Shimizu Corporation wind tunnel; cross-section 1.55 m wide, 2.2 m high; power-law inflow, exponent 1/4
reference roofs SMB: Shinjuku-Mitsui Building, roof G.L.+210 m, anemometer G.L.+237 m, for NW-NE
KDD: KDD Building, roof G.L.+165 m, anemometer G.L.+187 m, for the other directions
Nomenclature: symbols, columns and scores

Geometry, reference scales and release

  • \(H\), \(b\), \(D\) (m) — height of the building, cube, tower or tree belt; width of the building; edge of the cubes of Case C: the lengths the cases are drawn and normalised by
  • \(U_H\) (m/s) — reference speed: the mean approach-flow speed at the height \(H\) (each Data page gives the value used)
  • \(U_R\), \(H_R\), \(Z_R\) (m/s, m) — reference speed and height of a workbook: Case E, \(U_R\) at \(Z_R\) = 250 m full scale (1 m in the model); Case M, \(U_R\) and \(H_R\) at the reference point of the tunnel and of each field run
  • \(U_{\mathrm{ref}}\), \(L_{\mathrm{ref}}\) (m/s, m) — reference speed and length of a case’s normalisation: \(U_H\) and \(H\) (\(U_R\) and \(H_R\) in Case M); for the velocity ratios the approach speed at 15.9 m (Case E) or at 500 m (Case F)
  • \(U_b\) (m/s) — Case G: mean approach-flow speed at 9 m, the normalisation of its approach-flow table
  • \(q\), \(c_{\mathrm{gas}}\) (m³/s, ppm) — tracer release of the experiment: volume flow of the released gas, and its tracer content (\(10^6\) ppm when pure); \(Q\) is the source strength given to a solve
  • \(R_b\) (dimensionless) — bulk Richardson number of the heated-floor cases J and L (negative: unstable stratification)
  • \(\mathrm{Re_H}\), \(\mathrm{Re_D}\) (dimensionless) — Reynolds numbers \(U_H H/\nu\) and \(U_H D/\nu\) (\(\nu\): kinematic viscosity of air)
  • \(u_\ast\), \(z_0\), \(\kappa\) (m/s, mm, dimensionless) — friction velocity and roughness length of the log law fitted to the approach flow, and the von Kármán constant (0.41)
  • \(\mathrm{WD}\) (column wind_direction_deg; °) — wind direction (each frame says how it is counted); \(\mathrm{WD_R}\) is the mean direction of a field run at its reference point (Case M)
  • \(x\), \(y\), \(z\) (columns x, y, z; m) — coordinates in the case’s frame (\(+x\), \(+y\) and \(+z\) are the positive directions; each Data page says which way \(+x\) points), \(z\) up from the floor of the tunnel or from the ground
  • \(\mathrm{d}x\) (m) — lattice spacing of the OpenLB and FluidX3D runs, in metres or as a fraction of \(H\) (\(H/64\))
  • \(L_r\) (m) — reattachment length behind the building, read from a wake line at ground level; reported as \(L_r/H\)

Velocity and turbulence

  • \(U\), \(V\), \(W\) (columns U, V, W; m/s) — mean velocity along \(+x\), \(+y\), \(+z\); \(V\) is positive toward \(+y\) in every case
  • \(\lvert\mathbf{U}\rvert\) (m/s) — magnitude of the mean velocity vector, \(\sqrt{U^2+V^2+W^2}\)
  • \(V_{\mathrm{s}}\) (column Vs; m/s) — mean omnidirectional scalar speed of a thermistor (never a vector magnitude)
  • \(\overline{u'u'}\), \(\overline{v'v'}\), \(\overline{w'w'}\) (columns uu, vv, ww; m²/s²) — velocity variances (overbar: time average, prime: fluctuation about it)
  • \(\overline{u'v'}\), \(\overline{u'w'}\), \(\overline{v'w'}\) (columns uv, uw, vw; m²/s²) — Reynolds shear stresses
  • \(k = \tfrac{1}{2}\left(\overline{u'u'}+\overline{v'v'}+\overline{w'w'}\right)\) (column k; m²/s²) — turbulent kinetic energy
  • \(U/U_{\mathrm{ref}}\) (column velocity_ratio; dimensionless) — mean speed over the case’s reference speed (\(V_{\mathrm{s}}/U_{\mathrm{ref}}\) for a thermistor)
  • \(\sigma_{U/U_{\mathrm{ref}}}\) (column velocity_ratio_sd; dimensionless) — standard deviation of velocity_ratio over the observations behind a field value (Case F)
  • \(k/U_{\mathrm{ref}}^2\) (column k_ratio; dimensionless) — turbulent kinetic energy over the square of the reference speed, where only normalised values are published (Case G)

Concentration and temperature

  • \(C\) (column C; ppm) — mean tracer-gas concentration as published (volume fraction \(\times 10^6\) of the released gas diluted in air)
  • \(c_{\mathrm{rms}}\) (column c_rms; ppm) — root mean square of the concentration fluctuation
  • \(c_0\) (ppm) — reference concentration, defined for each case on its Data page: \(c_0 = \dfrac{c_{\mathrm{gas}}\thinspace q}{U_H H^2}\) (\(U_R H_R^2\) in the denominator in Case M)
  • \(c^\ast\) (column concentration_ratio; dimensionless) — dimensionless concentration \(c^\ast = C/c_0\); the value of a solve is \(c\thinspace U_H H^2/Q\) for its mean concentration \(c\) and its source strength \(Q\)
  • \(\mathrm{Sc_t}\) (dimensionless) — turbulent Schmidt number of a solve (0.3, 0.5 and 0.7)
  • \(T\), \(T_{\mathrm{rms}}\) (columns T, T_rms; °C, K) — mean air temperature as published (Cases J and L) and the root mean square of its fluctuation
  • \(\overline{u'c'}\), \(\overline{v'c'}\), \(\overline{w'c'}\) (columns uc, vc, wc; ppm·m/s) — turbulent concentration fluxes
  • \(\overline{u'\theta'}\), \(\overline{v'\theta'}\), \(\overline{w'\theta'}\) (columns uT, vT, wT; K·m/s) — turbulent heat fluxes (\(\theta'\): the temperature fluctuation)
  • \(\theta = \dfrac{T_f - T}{T_f - T_H}\) (dimensionless) — floor-referenced temperature the solves of Cases J and L are scored on: 0 at the floor, 1 in the approach air at \(H\); \(T_f\) is the floor temperature and \(T_H\) the temperature of the approach flow at \(H\)

Scores

  • \(n\) — number of pairs of a measured value \(o_i\) and a modelled value \(p_i\) at one point
  • \(R\) — Pearson correlation coefficient of the pairs
  • \(R^2\) — square of \(R\): share of the measured variance a linear fit to the model explains
  • \(\mathrm{FAC2}\) — fraction of pairs with \(0.5 \le p_i/o_i \le 2\)
  • \(\mathrm{FB}\) — fractional bias \(2(\overline{o}-\overline{p})/(\overline{o}+\overline{p})\), positive when the model is low
  • \(\mathrm{HR}\) (hit rate) — fraction of pairs with \(\lvert p_i-o_i\rvert/\lvert o_i\rvert \le \delta_{\mathrm{rel}}\) or \(\lvert p_i-o_i\rvert \le \delta_{\mathrm{abs}}\), where \(\delta_{\mathrm{rel}} = 0.25\) and \(\delta_{\mathrm{abs}} = 0.05\thinspace U_H\) for a velocity component
  • \(\mathrm{NMSE} = \dfrac{\overline{(o-p)^2}}{\overline{o}\thinspace \overline{p}}\) — normalised mean square error
  • \(\mathrm{NAD} = \dfrac{\overline{\lvert o-p\rvert}}{\overline{o}+\overline{p}}\) — normalised absolute difference
  • \(\mathrm{MG} = \exp\overline{(\ln o-\ln p)}\) — geometric mean bias
  • \(\mathrm{VG} = \exp\overline{(\ln o-\ln p)^2}\) — geometric variance
  • The ratio of \(\mathrm{FAC2}\) keeps its sign, so a model of the other sign than the measurement is a miss; \(\mathrm{FB}\), \(\mathrm{NMSE}\) and \(\mathrm{NAD}\) divide by the means, so they are undefined (shown as —) for a signed component unless the measured and the modelled mean are both positive
  • VDI 3783-9 calls the hit rate \(q\) and the tolerances \(D\) and \(W\); on this site those letters keep their other meanings (\(q\) the tracer release rate, \(D\) the block size of Case C, \(W\) the vertical velocity)
  • The detection limit of a concentration is one value per case, \(10^{-3}\) of the largest measured value. It sets \(\delta_{\mathrm{abs}}\) of the hit rate and the both-below rule of \(\mathrm{FAC2}\), and floors the values in \(\mathrm{MG}\) and \(\mathrm{VG}\).
  • The scores \(\mathrm{FB}\), \(\mathrm{FAC2}\), \(\mathrm{NMSE}\), \(\mathrm{NAD}\), \(\mathrm{MG}\) and \(\mathrm{VG}\) follow Chang & Hanna (2004); the hit rate follows VDI 3783-9.

Quantities scored

  • \(U\), \(V\) and \(W\) (mean velocity components) over \(U_H\)
  • \(k\) (turbulent kinetic energy) over \(U_H^2\)
  • the speed \(\lvert\mathbf{U}\rvert\) and \(\sqrt{\lvert\mathbf{U}\rvert^2+2k}\), against a thermistor’s \(V_{\mathrm{s}}\)
  • \(c^\ast = C/c_0\) (dimensionless concentration) at turbulent Schmidt numbers \(\mathrm{Sc_t}\) of 0.3, 0.5 and 0.7
  • \(\theta\) (floor-referenced temperature)

Frame and units

Property Definition
Origin centre of the reproduced district, tunnel floor plane
x \(+x\) EAST (full-scale metres)
y \(+y\) NORTH (compass rose in MP_caseF.png)
z \(+z\) up from the TUNNEL FLOOR; the readme's rule is ground = z - 10 m (the STL's terrain under the points is at \(z = 5\thinspace\mathrm{m}\))
Wind direction convention compass FROM-direction (N = 0, E = 90), so N blows toward -y; flow_dir = (-sin WD, -cos WD). Not stated by the sources; supported by the reference-building choice and by upwind roughness, and at NNW by a solved field (status 'corroborated by a solved field'; the other directions stay 'unverified').
Lateral sign applied 1
Coordinate scale applied 800.0
Unit of length m (FULL scale)
Unit of \(U/U_{\mathrm{ref}}\) dimensionless
Unit of \(\sigma_{U/U_{\mathrm{ref}}}\) dimensionless

Reference data

Source in this repository: raw/cases/case-f/RS-WT_caseF.csv (approach flow: raw/cases/case-f/AF_caseF.csv).

The cleaned table has 472 rows over 13 distinct points; columns point_id, config, instrument, wind_direction, wind_direction_deg, x, y, z, velocity_ratio, campaign, velocity_ratio_sd.

Unmeasured cells (null): velocity_ratio_sd 264.

The 40 configurations and their points
Configuration Points
default, field, cup anemometer, N, WD 0° 13
default, field, cup anemometer, NNE, WD 22.5° 13
default, field, cup anemometer, NE, WD 45° 13
default, field, cup anemometer, ENE, WD 67.5° 13
default, field, cup anemometer, E, WD 90° 13
default, field, cup anemometer, ESE, WD 112.5° 13
default, field, cup anemometer, SE, WD 135° 13
default, field, cup anemometer, SSE, WD 157.5° 13
default, field, cup anemometer, S, WD 180° 13
default, field, cup anemometer, SSW, WD 202.5° 13
default, field, cup anemometer, SW, WD 225° 13
default, field, cup anemometer, WSW, WD 247.5° 13
default, field, cup anemometer, W, WD 270° 13
default, field, cup anemometer, WNW, WD 292.5° 13
default, field, cup anemometer, NW, WD 315° 13
default, field, cup anemometer, NNW, WD 337.5° 13
default, wind tunnel, thermistor, N, WD 0° 13
default, wind tunnel, thermistor, NNE, WD 22.5° 13
default, wind tunnel, thermistor, NE, WD 45° 13
default, wind tunnel, thermistor, ENE, WD 67.5° 13
default, wind tunnel, thermistor, SE, WD 135° 13
default, wind tunnel, thermistor, SSE, WD 157.5° 13
default, wind tunnel, thermistor, S, WD 180° 13
default, wind tunnel, thermistor, SSW, WD 202.5° 13
default, wind tunnel, thermistor, SW, WD 225° 13
default, wind tunnel, thermistor, WNW, WD 292.5° 13
default, wind tunnel, thermistor, NW, WD 315° 13
default, wind tunnel, thermistor, NNW, WD 337.5° 13
h20, wind tunnel, thermistor, N, WD 0° 9
h20, wind tunnel, thermistor, NNE, WD 22.5° 13
h20, wind tunnel, thermistor, ENE, WD 67.5° 12
h20, wind tunnel, thermistor, S, WD 180° 11
h20, wind tunnel, thermistor, SSW, WD 202.5° 12
h20, wind tunnel, thermistor, SW, WD 225° 9
h20, wind tunnel, thermistor, NNW, WD 337.5° 13
h5, wind tunnel, thermistor, NNE, WD 22.5° 4
h5, wind tunnel, thermistor, ENE, WD 67.5° 8
h5, wind tunnel, thermistor, S, WD 180° 5
h5, wind tunnel, thermistor, SSW, WD 202.5° 5
h5, wind tunnel, thermistor, NNW, WD 337.5° 7

Columns

The columns of the cleaned table (points.csv, points.json), in order.

The 11 columns and what each holds
Column Symbol Meaning
point_id   the tunnel's own measurement point number
config   configuration key: 'default', Case C centre building '0D'/'1D'/'2D', Case E state 'bc' (before) / 'ac' (after construction)
instrument   'split_fibre' (vector components) or 'thermistor' (omnidirectional scalar speed)
wind_direction   compass name of the direction the wind comes FROM (Case E)
wind_direction_deg   AIJ wind direction in degrees; 0 is the case's reference direction (see frame)
x   m, case frame
y   m, case frame
z   m above ground, case frame
velocity_ratio \(U/U_{\mathrm{ref}}\) dimensionless, mean speed over the case's reference speed (Case E: \(V_{\mathrm{s}}/U(15.9\text{ m})\), \(U(15.9\text{ m})\) = 3.935 m/s; see the case's normalisation)
campaign   'wind_tunnel' (model scale) or 'field' (a full-scale observation: Cases F, G, M)
velocity_ratio_sd \(\sigma_{U/U_{\mathrm{ref}}}\) standard deviation of velocity_ratio over the observations behind a field value (Case F)

Inflow

Property Value
Method power law on the 18 published heights (z 10 … 400 m full scale); the data paper states exponent 1/4
Power-law exponent, fitted 0.277
Power-law exponent, data paper 0.25
\(U\) 500m m s data paper: 10.0
implied by profile: 10.65
Note AF_caseF.csv stops at 400 m (\(U\) = 10.0 m/s); the workbook's \(U/U_R\) profile (0.94 at 400 m) puts the 500 m speed at 10.65 m/s

Known data issues

  • The 16 field rows of point 14 in RS-FO_caseF.csv hold the workbook's value of the NEXT wind direction clockwise (the series is shifted by one); the cleaned table follows the workbook (clean/QUESTIONS.md QF1).
  • Tunnel and STL coordinates are MODEL scale (1:800); the field's are full scale. The case frame is full scale; the tunnel's \(x\), \(y\), \(z\) and the STL are multiplied by 800.
  • z is height above the tunnel floor. The readme's rule 'ground = z - 10 m' gives the 5 / 9 / 20 m planes, but the STL's terrain under all 13 points is at \(z = 5\thinspace\mathrm{m}\), so the planes stand 10 / 14 / 25 m above it.
  • BD_caseF.stl is wound inward on every ground, roof and sampled wall facet and is open along the rim of its 725 m disc (812 boundary edges); the served geometry.stl is re-wound outward and closed with a base slab down to \(z = -1\thinspace\mathrm{m}\).
  • MP_caseF.csv names the two reference points the other way round from the workbook, the STL and MP_caseF.png (the workbook's Shinjuku-Mitsui Building is the 225 m tower at (-17.5, 96.0), the KDD Building the 180 m one at (85.8, -347.1)).
  • Field values are the legacy workbook's roof-anemometer ratios times 0.940 (NW-NE) or 0.963 (other directions); sigma is the workbook's S.D. rounded to 0.01 times that factor, so it moves in steps of 0.0094 / 0.0096.
  • The tunnel did not run E, ESE, WSW or W; the field data cover all 16. The 5 m and 20 m planes exist at some points only (29 and 79 rows).
  • One tunnel value (point 8, SW, 9 m: 0.474) has no counterpart in the workbook's results sheet, and the flat 'Sheet1' table has 0.63 there.
  • Field anemometer heights above the tunnel floor are 13 - 21 m (3 - 11 m above ground by the readme's rule); the data paper says 3 - 9 m, so points 13 and 14 (11 m) disagree.
  • The thermistor reads a SCALAR speed and the cup anemometer a 10-minute mean: a RANS \(\lvert\mathbf{U}\rvert\) is biased low against both.
  • The files do not say whether a wind direction names where the wind comes from. The cleaned tables read it as the direction the wind comes from (N = 0, E = 90). At NNW a solved field supports that reading: Eddy3D's OpenFOAM 12 run for the wind from NNW correlates R 0.935 with the tunnel's 9 m column labelled NNW and R 0.077 with its column labelled SSE, the opposite wind (clean/QUESTIONS.md QF9); the other directions are not solved and stay unverified.

API

Attribution

  • Data collected by K. Fujii, Y. Asami, Y. Iwasa et al. (the original 1978 investigation; the readme names no data collectors).
  • Edited and distributed by Yoshihide Tominaga (Niigata Institute of Technology), Hideki Kikumoto (The University of Tokyo) and Tsubasa Okaze (Institute of Science Tokyo).
  • DOI: 10.5281/zenodo.15589621
  • Citation requested: Fujii, K., Asami, Y., Iwasa, Y. et al. (1978). Wind in Shinjuku Sub-Central Area — Comparison Between Field Measurement and Wind Tunnel Experiment. Proc. 5th Symposium on Wind Resistance of Structures, 91-98 (in Japanese).
  • Licence: CC BY 4.0

Cite

APA

Tominaga, Y., Kikumoto, H., & Okaze, T. (2025). AIJ UWE Benchmark Dataset – Case F (Shinjuku): Wind Tunnel Experiment and Field Observation for Flow within an Actual Urban Area in Shinjuku [Data set]. Zenodo. https://doi.org/10.5281/zenodo.15589621

BibTeX

@misc{aijuwe_case_f,
  author    = "Tominaga, Yoshihide and Kikumoto, Hideki and Okaze, Tsubasa",
  title     = "{AIJ UWE Benchmark Dataset -- Case F (Shinjuku): Wind Tunnel Experiment and Field Observation for Flow within an Actual Urban Area in Shinjuku}",
  year      = "2025",
  publisher = "Zenodo",
  doi       = "10.5281/zenodo.15589621",
  url       = "https://doi.org/10.5281/zenodo.15589621",
  note      = "Data set"
}

API: see About.